X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21880

Well Details

Well ID: 34-035-21880
Loading map...
County: Cuyahoga
Municipality:
Operator Name: M & M ROYALTY LTD
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2006-08-18
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.54966881
Longitude: -81.41255507

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2006-0 49.0 0.0
2007-0 53271.0 237.0
2008-0 34274.0 116.0
2009-0 22032.0 58.0
2010-0 9138.0 0.0
2011-0 22818.0 92.0
2012-0 35090.0 143.0
2013-0 37337.0 58.0
2014-0 22228.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
129425187 2013-02-25 The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6' board-on-board enclosure. There has been some minor oil leakage from the stuffing box seals. There is a 500-gallon poly tank in the enclosure being used for work-over chemical storage and application. The tank battery is located 50 feet east of the wellhead, and is comprised of 2 100-barrel (BBL) tanks, 1 50-BBL tank, mechanical separator, and associated piping and appurtenances enclosed in an 8' board-on-board enclosure. The system is lacking a charcoal filter at the vent stack. I observed discarded oilfield piping laying on the ground ouotside the enclosures. I spoke with Bob Allen of M&M Royalty. I advised him that the following actions are required: the poly tank requires seconday containment or should be moved to the tank battery, discarded debris must be removed from the site, oil staining needs mitigation, and the vent stack must have a charcoal filter. He indicated that he was heading to the site the next day to address the issues.
1573478712 2007-01-22
1603070066 2014-04-04 The producing unit is comprised of a pump jack and tank battery is separate board-on-board enclosures. The unit is producing with no observed problems. The well had recently undergone work over maintenance. There has been a problem with accumulation of salt at the pump, but is functioning at this time.
-1916933609 2008-08-11
274729345 2006-11-07 tanks set revised closer to well site
504969278 2006-08-21 checked status drilling 3000'
701418929 2006-05-18 Location made silt fence installed

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.