34-035-21880

Well Details

Well ID: 34-035-21880
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: CALAMARI UNIT
License Status: Producing
License Date: 2006-01-06
Spud Date: 2006-08-18
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-08-22
Well Total Depth: 3240.00 ft
Configuration: Vertical
Latitude: 41.540000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-01-06 Proposed Formations:CLINTON, Issued Date:1/6/2006, Expired Date:1/6/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-08-22 RBDMS Rec
Reached Total Depth 2006-08-22 RBDMS Rec
Construction Permit Expires 2007-01-06 RBDMS Rec
Completion Report Received 2007-01-17 RBDMS Rec
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-03-29 3085 3158 66
3085 3158 66
3085 3158 66

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 M & M ROYALTY LTD 49.00 0.00 365
2007 M & M ROYALTY LTD 53271.00 237.00 365
2008 M & M ROYALTY LTD 34274.00 116.00 365
2009 M & M ROYALTY LTD 22032.00 58.00 365
2010 M & M ROYALTY LTD 9138.00 0.00 365
2011 M & M ROYALTY LTD 22818.00 92.00 365
2012 M & M ROYALTY LTD 35090.00 143.00 366
2013 M & M ROYALTY LTD 37337.00 58.00 365
2014 M & M ROYALTY LTD 22228.00 0.00 365
2015 SOUND ENERGY CO INC 13441.00 0.00 305
2016 SOUND ENERGY CO INC 0.00 0.00 0
2017 SOUND ENERGY CO INC 2389.00 0.00 365
2018 SOUND ENERGY CO INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 M & M ROYALTY LTD Brine 380 365
2007 M & M ROYALTY LTD Brine 4032 365
2008 M & M ROYALTY LTD Brine 3130 365
2009 M & M ROYALTY LTD Brine 2375 365
2010 M & M ROYALTY LTD Brine 1960 365
2011 M & M ROYALTY LTD Brine 4104 365
2012 M & M ROYALTY LTD Brine 6124 366
2013 M & M ROYALTY LTD Brine 5860 365
2014 M & M ROYALTY LTD Brine 5443 365
2015 SOUND ENERGY CO INC Brine 4682 305
2016 SOUND ENERGY CO INC Brine 0 0
2017 SOUND ENERGY CO INC Brine 3656 365
2018 SOUND ENERGY CO INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1916933609 2008-8-11 0:00: PW No Violations
0129425187 2013-02-25 UrbanProduction Wells No Violations The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead consists of a pumpjack system in a 6 board-on-board enclosure. There has been some minor oil leakage from the stuffing box seals. There is a 500-gallon poly tank in the enclosure being used for work-over chemical storage and application. The tank battery is located 50 feet east of the wellhead, and is comprised of 2 100-barrel (BBL) tanks, 1 50-BBL tank, mechanical separator, and associated piping and appurtenances enclosed in an 8 board-on-board enclosure. The system is lacking a charcoal filter at the vent stack. I observed discarded oilfield piping laying on the ground ouotside the enclosures. I spoke with Bob Allen of M&M Royalty. I advised him that the following actions are required: the poly tank requires seconday containment or should be moved to the tank battery, discarded debris must be removed from the site, oil staining needs mitigation, and the vent stack must have a charcoal filter. He indicated that he was heading to the site the next day to address the issues.
0274729345 2006-11-07 Drill / Deepen / Reopen No Violations tanks set revised closer to well site
0504969278 2006-08-21 Drill / Deepen / Reopen No Violations checked status drilling 3000
0701418929 2006-05-18 Drill / Deepen / Reopen No Violations Location made silt fence installed
0912463429 2017-11-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection the wellhead and battery board-on-board enclosures were closed and locked. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment as intact and free from signs of release, leaks, or problems. The well was not in active production. The chart was inactive. The domestic tie-in was closed. Production reports were current with no production reported for 2016. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape.
129425187 2013-2-25 0:00: UP No Violations
1442944080 2015-09-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located in a residential area near Chagrin River Road. The area immediately surrounding the well is comprised of a small wooded portion of a larger parcel. Access to the well and battery are afforded by an unpaved, dedicated lease road which enters from Brigham Road and travels 200 feet to the unit. At the time of this inspection, the well is in production and records are current. Enclosure gates are locked and secure. Load-lines are locked and secure. Fittings at the wellhead and battery are secure and free from leakage. ID signage is present and has been updated to reflect change of owner. I met with well tender Harry Himmelright at this location and advised that empty containers and other unused equipment should be removed from the well enclosure. The access road is in good condition and well drained.
1573478712 2007-01-22 Preliminary Restoration No Violations
1603070066 2014-04-04 UrbanProduction Wells No Violations The producing unit is comprised of a pump jack and tank battery is separate board-on-board enclosures. The unit is producing with no observed problems. The well had recently undergone work over maintenance. There has been a problem with accumulation of salt at the pump, but is functioning at this time.
1916933609 2008-08-11 Production Wells No Violations
274729345 2006-11-7 0:00: DD No Violations
504969278 2006-8-21 0:00: DD No Violations
701418929 2006-5-18 0:00: DD No Violations
912463429 2017-11-20 0:00 UP No Violations 0.50

For data sources see[9]