If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-127-20017 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.765889,"lon":-75.109389,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Wayne | |
Municipality: Damascus Township | |
Operator Name: NEWFIELD APPALACHIA PA LLC | |
Well Pad ID: | |
Farm/Lease Name: WOODLAND MGMT PARTNERS 1 1 | |
License Status: Plugged OG Well | |
Spud Date: 06/25/2010 | |
Permit Date: 5/27/2010 | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Latitude: 41.765889 | |
Longitude: -75.109389 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | 0.00 | 0.00 | 0.00 | ||||
2011 | 0.00 | 0.00 | 0.00 | ||||
2012 | 0.00 | 0.00 | 0.00 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2010-A00 | Drill Cuttings (in Tons) | 26.00 Tons | LANDFILL | 101247 |
2010-A00 | Drilling Fluid Waste (in Barrels) | 2,795.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010-A00 | Drilling Fluid Waste (in Barrels) | 3,720.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1900332 | Primary Facility | 07/22/2010 | Drilling/Alteration | No Violations Noted | UDI rig 48. 20" conductor set. Rigging up to start drilling 13 3/8" casing. Reserve pit in good condition. Freeboard = 5'. Work area is lined with plastic and perimeter around rig is bermed. Drillers log on site and up to date. Mudlogger on site to log hole fro surface to TD. |
1912355 | Primary Facility | 09/02/2010 | Follow-up Inspection | No Violations Noted | Well installation complete. Rig moved off location to Crum. Reserve pit still open and full of fluid. Freeboard ok and liner in good condition. Plan to solidify and encapsulate pit next week. |
1912375 | Primary Facility | 09/08/2010 | Follow-up Inspection | No Violations Noted | Complaint of Sulphur odor coming from site. Contractor in process of dewatering pit. Fluid transferred to frac tanks and then trucked offsite for disposal. When pumping- odor emiited through vents on tanks. Pit is going to be solidified and then encapsulated this week. |
1926591 | Primary Facility | 11/02/2010 | Routine/Complete Inspection | No Violations Noted | Mike O'Donnell and I conducted an inspection of this site. We recommend that the operator update the E&S plan to accurately reflect the controls as installed. |
1966501 | Primary Facility | 04/18/2011 | Routine/Complete Inspection | No Violations Noted | on site with WQS Ryan Klemish. Inspected site and well head. Well is shut in. Pressure gauge on well indicated 0 psi. Cellar full of water. No gas bubbling observed. Well head and cellar are protected by chain-link fence and gae with pad lock. There was no activity on site at time of inspection. no violations were observed at the time of inspection. |
1966630 | Primary Facility | 04/18/2011 | Follow-up Inspection | Violation(s) Noted | |
1968208 | Primary Facility | 04/20/2011 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | Meeting with Newfield representative to discuss their response to my findings on 4/18/2011. |
1969810 | Primary Facility | 05/02/2011 | Follow-up Inspection | No Violations Noted | Followup to close out violations from 4/18/2011. No viols noted. |
2009350 | Primary Facility | 10/06/2011 | Routine/Complete Inspection | No Violations Noted | DEP on site at 10 am. Operator has filed for Inactive Status. Site is secured with entrance gate and chain-link fence around well head. Well is temporarily shut in. No leaks observed visually in cellar. No activity on site site during inspection. E&S controls appear to be in place and working sufficiently. DEP offsite at 10:30 |
2099639 | Primary Facility | 08/30/2012 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | On site 11:30. Gate locked. Operator provided access. No one on site at time of inspection. Well has been plugged. Well head removed and casing cut off below grade. A time of inspection cellar was full of water from recent rains. Could not see well. Operator has provided prictures of well with welded cap that has permit number welded on it. No violations observed. |
2101959 | Primary Facility | 09/19/2012 | Routine/Complete Inspection | No Violations Noted | Today is the second day of the reclamation activity being conducted of this pad. Monday, 9/17/12 was the first day of earth moving activity. Tuesday, 9/18/12 was a day of rain. Plans are on site, but in a weathered condition, need to be replaced. Weather is sunny today, with the next forecasted rain event being called for on Saturday, 9/22/12. Contractor is minimizing soil disturbance to north section of pad. Contractor is operating under the assumption that the originally installed silt sock is acceptable to meeting the designed runoff reduction criteria. A review of this “existing” silt sock shows that it needs to be replaced immediately. Also, debris from the existing silt sock needs to be removed. Told Ted that he can continue to conduct earth moving activities until a rain event is eminent. Hence, it was agreed that if new silt sock is not installed by the close of business on Friday, 9/22/12, |
2102817 | Primary Facility | 09/26/2012 | Routine/Complete Inspection | No Violations Noted | Inspection conducted with Ted Korb of Leeward Construction, contractor for Newfield Appalachia, on 9/26/12 of the Woodland Mgt. Partners well pad. Ted had called and left message on this past Friday, 9/21/12, stating that the required silt sock had been installed. Inspection revealed that the silt sock was installed as per plan, and was installed properly. Approximately 90% of the pad has been leveled back near original contours. After final leveling, top soil pile will be distributed and leveled over site. The access road built for the pad is under one acre, and hence can stay in place if land owner so desires. |
2155629 | Primary Facility | 04/09/2013 | Routine/Complete Inspection | No Violations Noted | Inspection conducted on 4/9/13. The lower third of the site needs to be regraded, seeded, and mulched. The ruts located in this area are beginning to turn into gullies. Please provide documentation of the E & S inspections conducted over the last month. |
2273563 | Primary Facility | 05/12/2014 | Routine/Complete Inspection | No Violations Noted | Inspection conducted of the Newfield Woodland Mgmt Partners 1 1 Well Pad Site covered under the E&S well pad plan for the Newfield Woodland Mgmt Partners 1 1 Well (127-20017). Inspection conducted on 5/12/14. Inspection is to confirm Newfield’s assessment that the site meets the minimum requirements as defined in Chapter 102.22(C) for permanent stabilization which would thus fulfill the physical requirements necessary for the permits termination. The Department’s determination is that the site is not permanently stabilized and does not meet the criteria necessary for the permit’s termination. The well pad site has areas in the lower section which do not have 70% vegetative cover. Also, the access road entrance is washing out. Looks like the road side ditch which feeds the first cross culvert needs to be cleaned out and reshaped. Also, the level spreader for this cross culvert may need to be lowered. |
2322366 | Primary Facility | 11/13/2014 | Site Restoration | No Violations Noted | Inspection conducted of the Newfield Woodland Mgmt Partners 1 1 Well Pad Site covered under the E&S well pad plan for the Newfield Woodland Mgmt Partners 1 1 Well (127-20017). Inspection conducted on 11/13/14. Inspection is to confirm Newfield’s assessment that the site meets the minimum requirements as defined in Chapter 102.22(C) for permanent stabilization which would thus fulfill the physical requirements necessary for the permits termination. The Department’s determination is that the site is in fact stabilized and meets the criteria necessary for the permit’s termination. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1966630 | 609115 | 04/18/2011 | 01/07/2013 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Violation for failure to properly stabilize topsoil pile. Operator was originally advised of this issue in inspection conducted 11/2/2010.. |
For data sources see[6]