37-129-28953

Well Details

Well ID: 37-129-28953
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Upper Burrell Township
Operator Name: HUNTLEY & HUNTLEY ENERGY EXPLORATION LLC
Well Pad ID: 154469
Farm/Lease Name: ZEUS 6M
License Status: Active
Spud Date: 03/27/2018
Permit Date: 10/17/2017
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.579097
Longitude: -79.669006

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 HUNTLEY & HUNTLEY ENERGY EXPLORATION LLC 2,048,170.00 162 0.00 0 0.00 0
2019 HUNTLEY & HUNTLEY ENERGY EXPLORATION LLC 880,991.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2018-M04 Drill Cuttings (in Tons) RWC 810 731.87 Tons LANDFILL 100280
2018-M04 Drilling Fluid Waste (in Barrels) RWC 803 2,570.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M04 Other Oil & Gas Wastes (in Barrels) RWC 899 1,115.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M05 Drill Cuttings (in Tons) RWC 810 836.25 Tons LANDFILL 100280
2018-M05 Drilling Fluid Waste (in Barrels) RWC 803 450.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M05 Other Oil & Gas Wastes (in Barrels) RWC 899 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018-M05 Other Oil & Gas Wastes (in Barrels) RWC 899 1,190.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M05 Synthetic Liner Materials (in Tons) RWC 806 28.81 Tons LANDFILL 100280
2018-M07 Other Oil & Gas Wastes (in Barrels) RWC 899 65.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018-M07 Produced Fluid (in Barrels) RWC 802 10,963.91 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018-M07 Produced Fluid (in Barrels) RWC 802 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018-M07 Produced Fluid (in Barrels) RWC 802 1,950.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2018-M08 Produced Fluid (in Barrels) RWC 802 11,704.91 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018-M08 Produced Fluid (in Tons) RWC 802 26.50 Tons LANDFILL 100280
2018-M08 Produced Fluid (in Tons) RWC 802 22.80 Tons LANDFILL 100594
2018-M09 Produced Fluid (in Barrels) RWC 802 4,322.16 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018-M09 Produced Fluid (in Tons) RWC 802 4.59 Tons LANDFILL 100280
2018-M10 Produced Fluid (in Barrels) RWC 802 2,214.28 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018-M11 Produced Fluid (in Barrels) RWC 802 835.41 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018-M11 Produced Fluid (in Barrels) RWC 802 1,847.10 Bbl REUSE (AT WELL PAD)
2018-M12 Produced Fluid (in Barrels) RWC 802 1,186.81 Bbl INJECTION DISPOSAL WELL 34-099-23158
2018-M12 Produced Fluid (in Barrels) RWC 802 921.00 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 117.81 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019-M01 Produced Fluid (in Barrels) RWC 802 1,109.00 Bbl REUSE (AT WELL PAD)
2019-M02 Other Oil & Gas Wastes (in Barrels) RWC 899 125.00 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 494.88 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019-M02 Produced Fluid (in Barrels) RWC 802 373.00 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 615.00 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2711383 Primary Facility 2018-03-28 Drilling/Alteration No Violations Noted This well was spudded on 3/27/2018 at 11:15am. The spud rig drilled a 9' cellar hole and a 8'x8' cellar ring was installed. The spud rig then drilled a conductor hole 42'x30" and a mouse hole to 75'.

On 3/28/2018 the rig set 42' of 26" conductor pipe and 75' of 16 " mouse hole pipe. The conductor pipe was grouted back to the cellar surface.

There was a trace of water encountered at 9'.

The operator has installed a sound wall completely around this well pad.

All equipment on site looked ok.

2718458 Primary Facility 2018-04-16 Drilling/Alteration No Violations Noted This well was spudded on 3/27/2018 at 11:15am. The spud rig drilled a 9' cellar hole and a 8'x8' cellar ring was installed. The spud rig then drilled a conductor hole 42'x30" and a mouse hole to 75'.

On 3/28/2018 the rig set 42' of 26" conductor pipe and 75' of 16 " mouse hole pipe. The conductor pipe was grouted back to the cellar surface.

There was a trace of water encountered at 9'.

The operator has installed a sound wall completely around this well pad. At the time of this inspection the Rig was drilling at 650'.

All equipment on site looked ok.

2721408 Primary Facility 2018-04-23 Drilling/Alteration No Violations Noted This well was spudded on 3/27/2018 at 11:15am. The spud rig drilled a 9' cellar hole and a 8'x8' cellar ring was installed. The spud rig then drilled a conductor hole 42'x30" and a mouse hole to 75'.

On 3/28/2018 the rig set 42' of 26" conductor pipe and 75' of 16 " mouse hole pipe. The conductor pipe was grouted back to the cellar surface.

There was a trace of water encountered at 9'.

The operator has installed a sound wall completely around this well pad. At the time of this inspection the Rig was drilling at 650'.

All equipment on site looked ok.

2724472 Primary Facility 2018-04-30 Drilling/Alteration No Violations Noted This well was spudded on 3/27/2018 at 11:15am. The spud rig drilled a 9' cellar hole and a 8'x8' cellar ring was installed. The spud rig then drilled a conductor hole 42'x30" and a mouse hole to 75'.

On 3/28/2018 the rig set 42' of 26" conductor pipe and 75' of 16 " mouse hole pipe. The conductor pipe was grouted back to the cellar surface.

There was a trace of water encountered at 9'.

The operator has installed a sound wall completely around this well pad. At the time of this inspection the Rig was drilling at 8908'.

All equipment on site looked ok.

2726953 Primary Facility 2018-05-07 Drilling/Alteration No Violations Noted This well was spudded on 3/27/2018 at 11:15am. The spud rig drilled a 9' cellar hole and a 8'x8' cellar ring was installed. The spud rig then drilled a conductor hole 42'x30" and a mouse hole to 75'.

On 3/28/2018 the rig set 42' of 26" conductor pipe and 75' of 16 " mouse hole pipe. The conductor pipe was grouted back to the cellar surface.

There was a trace of water encountered at 9'.

The operator has installed a sound wall completely around this well pad. At the time of this inspection the Rig was drilling at 17105'.

All equipment on site looked ok.

2741303 Primary Facility 2018-06-14 Drilling/Alteration No Violations Noted Stimulating well.
2753012 Primary Facility 2018-07-17 Complaint Inspection Violation(s) Noted Present during inspection is operator rep Scott Krueger.

Well head surrounded by cement barriers. At time of inspection 8 roll off boxes on site. These boxes are on secondary containment. Contractors are removing the panels from the noise reduction wall. Contractors are removing the temporary water transmission lines. According to Mr. Krueger well is drilled and frac'ed but flow back has not begun.

2760868 Primary Facility 2018-08-06 Compliance Evaluation No Violations Noted CEI to inspection record #2753012 where a violation was issued for failure to notify the Department within 24 hours of receiving notification that a water supply has been affected by pollution or diminution.

Department received response to NOV from operator (photo #1). Violation issued on 7-17-18 has been corrected.

2764374 Primary Facility 2018-08-14 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Brine tank appears structurally sound and within secondary containment. GPU within secondary containment. Drilling equipment and materials located on containment. No E&S issues.

Previously issued site violations remain outstanding.

2769562 Primary Facility 2018-08-31 Routine/Complete Inspection No Violations Noted At the time of inspection well appears equipped for production. Brine tanks and GPUs within secondary containment and appears structurally sound. No E&S issues.
2775340 Primary Facility 2018-09-14 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Two brine tanks within secondary containment and appears structurally sound. GPUs within secondary containment and appears structurally sound. No E&S issues.
2806862 Primary Facility 2018-11-27 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Brine tanks and GPUs within secondary containment. No E&S issues.
2827411 Primary Facility 2019-01-16 Routine/Complete Inspection No Violations Noted Conductor and cellar set.

1/16/19 - Well producing. Preparing to move rig on site.

2843580 Primary Facility 2019-02-22 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Brine tank within secondary containment and appears structurally sound. GPU within secondary containment. No E&S issues.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2753012 823320 2018-07-17 2018-08-06 78.51(h) Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
823320 365883 NOV - Notice of Violation 2018-08-06

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/08/2018 06/21/2018 7299 17,577,600.0 23,432,600.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (100 Mesh Proppant) ProFrac Proppant Listed Below
ProFE 105 ProFrac Iron Control Listed Below
Scaletreat 30 Clariant Scale Inhibitor Listed Below
Hydrochloric Acid (7.5%) Cooper Natural Acidizing Listed Below
Flotreat DR 15635 Clariant Friction Reducer Listed Below
Water Rockdale Energy Carrier/Base Fluid 7732-18-5
ProHib 100 ProFrac Acid Inhibitor Listed Below
Hydrochloric Acid (Hydrogen Chloride)Hydrochloric Acid (Hydrogen Chloride) 7647-01-0 36 0.20036
Quaternary Ammonium Chloride 68391-01-5 3 0.0056
Glutaraldehyde 111-30-8 20 0.00374
2-Propyn-1-ol compound w/ methyloxirane 38172-91-7 15 0.0025
Alcohols,C11-14-iso, C13-rich, ethoxylated 78330-21-9 5 0.00263
Dideclydimethylammonium Chloride 7173-51-5 3 0.0056
Water 7732-18-5 85 0.00142
Water 7732-18-5 63 0.35062
Silica Substrate 14808-60-7 100 13.686
Water 7732-18-5 70 0.0014
Citric Acid 77-92-9 40 0.0008
Sulphamic Acid 5329-14-6 5 0.0001

For data sources see[7]

References