34-153-22870

Well Details

Well ID: 34-153-22870
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Northampton Township
Operator Name: NORTH AMERICAN PETROLEUM INC
Well Pad ID:
Farm/Lease Name: NOVISKY
License Status: Producing
License Date: 1997-10-17
Spud Date: 1998-04-01
Spud Drilling Contractor: MARIC DRILLING CO.
Final Drill Date: 1998-04-08
Well Total Depth: 3890 ft
Configuration: Vertical
Latitude: 41.137535557
Longitude: -81.53622948

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1997-10-17 Proposed Formations:CLINTON, Issued Date:10/17/97, Expired Date:10/17/98 6:00:00 AM, Drilling unit acres:22.2293, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1998-04-01 RBDMS Rec
Completed 1998-04-08 RBDMS Rec
Reached Total Depth 1998-04-08 RBDMS Rec
Completion Report Received 1998-07-01 RBDMS Rec
Construction Permit Expires 1998-10-17 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-09-04 3709 3748 26

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 78000 Gal 60000 500 GALLONS 7.5% HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 NORTH AMER PETROLEUM INC 0 594 31
1999 NORTH AMERICAN PETROLEUM INC 7290 2269 365
2000 NORTH AMER PETROLEUM INC 8131 2118 365
2001 NORTH AMERICAN PETROLEUM INC 8234 1697 365
2002 NORTH AMERICAN PETROLEUM INC 4902 1318 365
2003 NORTH AMERICAN PETROLEUM INC 4093 1234 365
2004 NORTH AMERICAN PETROLEUM INC 3844 1033 365
2005 NORTH AMERICAN PETROLEUM INC 2712 740 365
2006 NORTH AMERICAN PETROLEUM INC 2234 767 365
2007 NORTH AMERICAN PETROLEUM INC 1990 600 365
2008 NORTH AMERICAN PETROLEUM INC 2183 731 365
2010 NORTH AMERICAN PETROLEUM INC 978 287 365
2011 NORTH AMERICAN PETROLEUM INC 802 301 365
2012 NORTH AMERICAN PETROLEUM INC 648 171 366
2013 NORTH AMERICAN PETROLEUM INC 168 197 88
2014 NORTH AMERICAN PETROLEUM INC 484 254 0
2015 NORTH AMERICAN PETROLEUM INC 254 119 365
2016 NORTH AMERICAN PETROLEUM INC 425 139 199
2017 NORTH AMERICAN PETROLEUM INC 117 91 87
2018 NORTH AMERICAN PETROLEUM INC 246 294 87

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 NORTH AMER PETROLEUM INC Brine 160 31
1999 NORTH AMERICAN PETROLEUM INC Brine 496 365
2000 NORTH AMER PETROLEUM INC Brine 326 365
2001 NORTH AMERICAN PETROLEUM INC Brine 196 365
2002 NORTH AMERICAN PETROLEUM INC Brine 112 365
2003 NORTH AMERICAN PETROLEUM INC Brine 107 365
2004 NORTH AMERICAN PETROLEUM INC Brine 52 365
2005 NORTH AMERICAN PETROLEUM INC Brine 0 365
2006 NORTH AMERICAN PETROLEUM INC Brine 118 365
2007 NORTH AMERICAN PETROLEUM INC Brine 111 365
2008 NORTH AMERICAN PETROLEUM INC Brine 54 365
2010 NORTH AMERICAN PETROLEUM INC Brine 0 365
2011 NORTH AMERICAN PETROLEUM INC Brine 20 365
2012 NORTH AMERICAN PETROLEUM INC Brine 0 366
2013 NORTH AMERICAN PETROLEUM INC Brine 0 88
2014 NORTH AMERICAN PETROLEUM INC Brine 365 0
2015 NORTH AMERICAN PETROLEUM INC Brine 0 365
2016 NORTH AMERICAN PETROLEUM INC Brine 0 199
2017 NORTH AMERICAN PETROLEUM INC Brine 0 87
2018 NORTH AMERICAN PETROLEUM INC Brine 0 87

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0501446691 2004-05-13 Production Wells No Violations Status check inspection - no violations at this time.
0589072137 2009-06-19 Production Wells No Violations The two siphon dams can be removed and the entire affected area can be reclaimed. The well still cannot be turned back into line until the containment dike is repaired.
0923363801 2009-06-16 Production Wells No Violations No change in the status of the well and tank battery. The lower siphon dam can be removed and the area reclaimed. The booms can be removed from the retention pond. The secondary containment dike still needs to be rebuilt before the well can be turned on and the upper siphon dam can be monitored for the next week.
1155309041 2009-06-03 Production Wells No Violations I received a call from Rick Batta at North American, reporting an oil spill at the Novisky well. The spill is a rule violation, but the company response was reasonably quick and effective. If the subsequent actions continue in a timely manor, a NOV will not be issued. The spill was caused by two events; 1) overfilling the 140 bbl stock tank and 2) insufficient secondary containment capacity. The spill exited the containment area and ran down the lease road to the landowners driveway, down both sides of the driveway via drainage ditches and into a retention pond. The driveway, ditches, culverts and pond were all impacted. According to the landowner, there are no discharge points from the retention pond other than overflow. The current pond level is at least three feet below that spill point. Moore Well Service was on site when I arrived and had started recovering oil with a vac truck. Additional equipment was enroute to install two siphon dams and continue product recovery. Additional recovery will continue tomorrow with hot water flushing and oil recovery.
1194542623 2009-06-26 Production Wells No Violations The affected areas have been graded but still need to be seeded and mulched. The siphon dams have been removed. The secondary containment dike has been raised several inches but needs additional attention. I passed this information on to Rick Batta.
1292102991 2009-07-09 Production Wells No Violations All of the spill issues have been addressed and corrected. I called Rick Batta and gave him permission to turn the well back into production.
1502102710 2009-06-04 Production Wells No Violations Two Moore Well Service vac trucks were on site flushing the impacted areas, when I arrived. A steam truck would not be available until tomorrow. The plan for today calls for flushing the impacted areas with fresh water and recovering any free oil. The catails in the pond will be cut off to allow for skimming the pond with both booms and suction.
1691679368 2009-06-05 Production Wells No Violations The hot water treatment was completed before I arrived on location. The majority of the spilled oil has been recovered from either the siphon dams or the retention pond. The siphon dams will remain for the next several weeks to collect any residual product and will be checked on a regular basis. I advised Rick Batta in a phone message, that the well cannot be turned back on until the secondary containment system meets the SPCC requirements.
2024730297 2009-06-11 Production Wells No Violations The lower siphon dam and the retention pond are in good condition. The lower siphon dam can be removed and the area can be graded and seeded. Any remaining impacted vegetation around this siphon dam can be removed. The upper siphon dam is still collecting small amounts of oil being released from the lease road stone, and needs to remain for the near future. The secondary containment dike around the tank battery still needs to be rebuilt before the well can be turned back on.

For data sources see[9]