34-153-22925

Well Details

Well ID: 34-153-22925
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: TRANSCONTINENTAL OIL & GAS INC
Well Pad ID:
Farm/Lease Name: O'NEILL
License Status: Producing
License Date: 2002-07-22
Spud Date: 2002-11-04
Spud Drilling Contractor: LANDOGS DRILLING
Final Drill Date: 2002-11-11
Well Total Depth: 3971 ft
Configuration: Directional
Latitude: 41.167616162
Longitude: -81.62899399

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2002-07-22 Proposed Formations:CLINTON, Issued Date:7/22/2002, Expired Date:7/22/2003 6:00:00 AM, Drilling unit acres:41.215, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2002-11-04 RBDMS Rec
Completed 2002-11-11 RBDMS Rec
Reached Total Depth 2002-11-11 RBDMS Rec
Completion Report Received 2003-03-27 RBDMS Rec
Correction to Well 2003-04-04 CHANGE IN TARGET LOCATION:401'SL & 176'EL OF LOT 46; X= 2,240,204 AND Y= 548,893. UNIT SIZE INCREASED TO 66.023 ACRES.
Construction Permit Expires 2003-07-22 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2003-05-15 3684 3760 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 105000 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2003 TRANSCONTINENTAL OIL & GAS INC 9448 1860 365
2004 TRANSCONTINENTAL OIL & GAS INC 13035 988 365
2005 TRANSCONTINENTAL OIL & GAS INC 6665 648 365
2006 TRANSCONTINENTAL OIL & GAS INC 5252 393 365
2007 TRANSCONTINENTAL OIL & GAS INC 3751 390 364
2008 TRANSCONTINENTAL OIL & GAS INC 3251 224 365
2009 TRANSCONTINENTAL OIL & GAS INC 2791 202 365
2010 TRANSCONTINENTAL OIL & GAS INC 5046 362 365
2011 TRANSCONTINENTAL OIL & GAS INC 6583 387 365
2012 TRANSCONTINENTAL OIL & GAS INC 5208 347 366
2013 TRANSCONTINENTAL OIL & GAS INC 3330 218 365
2014 TRANSCONTINENTAL OIL & GAS INC 2988 169 365
2015 TRANSCONTINENTAL OIL & GAS INC 4090 167 365
2016 TRANSCONTINENTAL OIL & GAS INC 3224 102 365
2017 TRANSCONTINENTAL OIL & GAS INC 2425 43 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2003 TRANSCONTINENTAL OIL & GAS INC Brine 808 365
2004 TRANSCONTINENTAL OIL & GAS INC Brine 45 365
2005 TRANSCONTINENTAL OIL & GAS INC Brine 33 365
2006 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2007 TRANSCONTINENTAL OIL & GAS INC Brine 50 364
2008 TRANSCONTINENTAL OIL & GAS INC Brine 33 365
2009 TRANSCONTINENTAL OIL & GAS INC Brine 0 365
2010 TRANSCONTINENTAL OIL & GAS INC Brine 210 365
2011 TRANSCONTINENTAL OIL & GAS INC Brine 100 365
2012 TRANSCONTINENTAL OIL & GAS INC Brine 70 366
2013 TRANSCONTINENTAL OIL & GAS INC Brine 35 365
2014 TRANSCONTINENTAL OIL & GAS INC Brine 35 365
2015 TRANSCONTINENTAL OIL & GAS INC Brine 105 365
2016 TRANSCONTINENTAL OIL & GAS INC Brine 37 365
2017 TRANSCONTINENTAL OIL & GAS INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0780460922 2002-11-18 Drill / Deepen / Reopen No Violations The drilling rig has moved off and the pits are being pumped out and solidified.
1037198559 2002-11-06 Drill / Deepen / Reopen No Violations Status check inspection on drilling operation. Just drilling out from under surface. 40 feet of cement was left inside the casing.
1886909233 2003-01-08 Production Wells No Violations November 18, 2002 - The subject site was inspected for the purpose of determining the distance between the tank battery under construction and a vacant house south of the tank battery. The inspection was prompted by a spacing question posed to me by the Bath Township Zoning office. A roustabout crew was on site at the time of this inspection and assisted in measuring the distance between the house and the nearest stock tank. The measured distance was 83 feet and the crew was informed of the minimum distance requirements, including 100 feet between an occupied dwelling and a stock tank. Mr. Cal Marks with Transcontinental was notified of the problem by phone. Several possible locations were discussed and I reminded him of the minimum spacing requirements before leaving the site. A NOV was not issued since the tank battery was not operational.

December 3, 2002 - I was informed that the tank battery was relocated south of house and that it met all spacing requirements. January 8, 2003 - The site was inspected and I was told by the same roustabout crew that the tanks were 108 feet from the house and 70 feet from the wellhead. The site has been rough graded and the pits have been solidified. The secondary containment dike has been constructed around the tank battery. The well will be turned on in the very near future. No violations at this time.

For data sources see[9]