X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-20296

Well Details

Well ID: 34-085-20296
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: MIHALIK PAUL
Well Pad ID:
Farm/Lease Name: TRESGER EDWARD H INC
License Status: Producing
License Date: 1980-07-17
Spud Date: 1980-08-05
Spud Drilling Contractor:
Final Drill Date: 1980-08-11
Well Total Depth: 3070 ft
Configuration: Vertical
Latitude: 41.751830668
Longitude: -81.21145431

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-07-17 858 DRILLEX INC GeoDate 7/17/80
Original Spud 1980-08-05
Completed 1980-08-11
Reached Total Depth 1980-08-11
Change of Owner 2003-10-06 Operator changed from 858, DRILLEX INC to 7531, MIHALIK PAUL
Record Last Modified 2019-06-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2900 2970 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 30000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DRILLEX INC 5155 26 0
1985 DRILLEX INC 3389 0 365
1986 DRILLEX INC 3303 26 365
1987 DRILLEX INC 4167 0 365
1988 DRILLEX INC 2885 0 365
1989 DRILLEX INC 1444 0 365
1990 DRILLEX INC 559 28 365
1991 DRILLEX INC 1634 14 365
1992 DRILLEX INC 2658 0 365
1993 DRILLEX INC 862 0 365
1994 DRILLEX INC 518 0 365
1995 DRILLEX INC 638 0 365
1996 DRILLEX INC 480 0 365
1998 DRILLEX INC 720 0 365
1999 DRILLEX INC 496 0 365
2000 DRILLEX INC 128 0 365
2001 DRILLEX INC 56 0 365
2002 DRILLEX INC 0 0 365
2003 DRILLEX INC 0 0 365
2004 MIHALIK PAUL 0 0 0
2005 MIHALIK PAUL 50 0 7
2006 MIHALIK PAUL 0 0 0
2008 MIHALIK PAUL 0 0 0
2009 MIHALIK PAUL 0 0 0
2010 MIHALIK PAUL 0 0 0
2011 MIHALIK PAUL 0 0 0
2012 MIHALIK PAUL 0 0 0
2013 MIHALIK PAUL 158 0 30
2014 MIHALIK PAUL 92 0 60
2015 MIHALIK PAUL 84 0 60
2016 MIHALIK PAUL 46 0 62
2017 MIHALIK PAUL 46 0 28

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DRILLEX INC Brine 185 0
1985 DRILLEX INC Brine 100 365
1986 DRILLEX INC Brine 147 365
1987 DRILLEX INC Brine 180 365
1988 DRILLEX INC Brine 110 365
1989 DRILLEX INC Brine 210 365
1990 DRILLEX INC Brine 23 365
1991 DRILLEX INC Brine 64 365
1992 DRILLEX INC Brine 147 365
1993 DRILLEX INC Brine 54 365
1994 DRILLEX INC Brine 93 365
1995 DRILLEX INC Brine 67 365
1996 DRILLEX INC Brine 75 365
1998 DRILLEX INC Brine 55 365
1999 DRILLEX INC Brine 35 365
2000 DRILLEX INC Brine 0 365
2001 DRILLEX INC Brine 42 365
2002 DRILLEX INC Brine 63 365
2003 DRILLEX INC Brine 80 365
2004 MIHALIK PAUL Brine 0 0
2005 MIHALIK PAUL Brine 0 7
2006 MIHALIK PAUL Brine 0 0
2008 MIHALIK PAUL Brine 0 0
2009 MIHALIK PAUL Brine 0 0
2010 MIHALIK PAUL Brine 0 0
2011 MIHALIK PAUL Brine 0 0
2012 MIHALIK PAUL Brine 0 0
2013 MIHALIK PAUL Brine 8 30
2014 MIHALIK PAUL Brine 0 60
2015 MIHALIK PAUL Brine 0 60
2016 MIHALIK PAUL Brine 0 62
2017 MIHALIK PAUL Brine 0 28

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0909908542 2010-11-19 Production Wells No Violations There were no violations at the time of inspection.
1418828649 2014-12-17 UrbanProduction Wells No Violations I inspected the location of this producing unit as part of routine inspection activity. The wellhead and battery are located . At the wellhead there is valve-tree and concoil system. The battery is comprised of 1 100-barrel production tank and separator. At the time of this inspection, the tank has been taken out of service. The well elements have been recently painted and are in good repair with no signs of leakage or problems. ID signage and secondary containment are present. Load-outs are bull-plugged.
1497483733 2013-05-13 UrbanProduction Wells No Violations I could not locate the wellhead. The tank battery consists of 1 100-barrel tank and mechanical separator, not enclosed. Secondary containment is present and adequate. Some brine leakage has occurred from the base of the tank. I contacted Paul Mihalik regarding the issue. He indicated that the tank will be replaced immediately.
1594252086 2017-11-17 UrbanProduction Wells No Violations I inspected this well location as a follow-up to Chiefs Order 2017-403., issued on 11/07/17 for non-reported produciton for 2016. At the time of this inspection, the well, comprised of a concoil-type plunger lift unit and tank battery with one steel, 100-barrel stock tank, was shut-in and not producing. I contacted Paul Mihalik about the production reports and he indicated that he is working on recovering the data that had been lost on a computer hard drive malfunction. He planned to file the report by the deadline.

For data sources see[9]

References