Well Details

Well ID: 37-115-22201
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150351
Farm/Lease Name: WARNER 5H
License Status: Active
Spud Date: 2016-09-17
Permit Date: 2016-08-22
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.830405
Longitude: -75.676542

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-05-10 2017-05-16 6998 8,499,630.0 91800

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric acid 7647-01-0 15 0.161056 135222
Diammonium phosphate 7783-28-0 5 0.0011005 924
Hydrotreated light petroleum distillate 64742-47-8 30 0.0253543 21288
Ammonium chloride 12125-02-9 30 0.00660302 5544
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00376699 3163
Inorganic salt Proprietary 30 0.0253543 21288
Water 7732-18-5 100 84.4297 70,886,700.0
Non-hazardous food substance Proprietary 100 0.000109577 93
Crystalline silica, quartz 14808-60-7 100 14.3523 12,050,100.0
Organic phosphonate Proprietary 60 0.013206 11088
Acrylamide acrylate copolymer Proprietary 30 0.0253543 21288
Water 7732-18-5 100 1.17529 986767
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below
Ingredients Listed Above Listed Above Listed Below
SAND-COMMON WHITE - 100 MESH, 3307 LB BAG Halliburton Proppant Listed Below
FR-76 Halliburton Friction Reducer Listed Below
LP-65 MC Halliburton Scale Inhibitor Listed Below
Fresh Water Operator Base Fluid Listed Below
HAI-150E Halliburton Corrosion Inhibitor Listed Below
HYDROCHLORIC ACID Halliburton Solvent Listed Below
BE-9 Halliburton Biocide Listed Below

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2016 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2017 SWN PROD CO LLC 2,223,835.00 211 0.00 0 0.00 0
2018 SWN PROD CO LLC 1,959,723.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 384,709.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 200.60 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Drill Cuttings (in Tons) RWC 810 328.53 Tons LANDFILL 101247
2016 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 12.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 165.20 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drilling Fluid Waste (in Barrels) RWC 803 440.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Produced Fluid (in Tons) RWC 802 5.73 Tons LANDFILL 301358
2017 SWN PROD CO LLC Unused Fracturing Fluid Waste (in Tons) RWC 805 60.06 Tons LANDFILL THR029
2017 SWN PROD CO LLC Servicing Fluid (in Tons) RWC 808 2.09 Tons LANDFILL THR029
2017 SWN PROD CO LLC Produced Fluid (in Tons) RWC 802 67.29 Tons LANDFILL THR029
2017 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 14,188.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drill Cuttings (in Tons) RWC 810 374.63 Tons LANDFILL 101247
2017 SWN PROD CO LLC Synthetic Liner Materials (in Tons) RWC 806 1.20 Tons LANDFILL 101247
2017 SWN PROD CO LLC Synthetic Liner Materials (in Tons) RWC 806 2.67 Tons LANDFILL 100933
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 368.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 133.43 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 1,919.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 440.60 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 22.00 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Other Oil & Gas Wastes (in Barrels) RWC 899 25.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid (in Barrels) RWC 802 375.60 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2520144 Primary Facility 2016-09-19 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 9:10a.m. for a new spud inspection, Well Service Group was on site drilling the holes and running the conductor pipes for the 1H,4H, and 5H. The rig was drilling the mouse hole for the 1H. The drill cuttings are being put into a sealed role off container and hauled to Keystone Landfill. I took a walk around the location and everything looked OK.

The conductor pipe was set and cemented at 43' on the 1H, set and cemented at 45' on the 5H, and the hole was drilled to 45' on the 4H but they were waiting for a water truck to get the water out of the hole before running and cementing the conductor pipe. I left the site at 9:40a.m.

2526696 Primary Facility 2016-10-11 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 11:20a.m., I met with company men Tom Fooshee, Falcon Rig 25 was on site and drilling the vertical section of the well to kick off. I took a walk around the location and there were no obvious concerns noticed.

Depth at time of inspection was 2834'. Projected TD for the top hole section is 5930' I left the site at 12:10p.m.

2590074 Primary Facility 2017-05-03 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 8:25a.m.

I met with company man Mark McPherson. Halliburton was on site to stimulate the 1H,4H, and 5H wells. They completed stage 1 out of 28 stages on the 4H and were running a correlation log on the well. The 1H was completed with 27 stages. The 5H hasn’t been started yet but will have 26 stages when completed. The water was being pumped to the site from the Zeffer production water impoundment. I took a walk around the location and there were no obvious concerns noticed. I left the site at 8:55a.m.

2625649 Primary Facility 2017-08-14 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:45p.m.

The well was recently completed and is in production. The well tag was on the well and correct. The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was cement between the (20x13) and (13x9) annuli and there was no gas detected. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 576psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:30p.m.

2677950 Primary Facility 2017-12-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. There was cement between the (20x13) and (13x9) annuli and there was no gas detected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2730470 Primary Facility 2018-04-25 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues were observed. No violations noted.
2773371 Primary Facility 2018-09-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 2.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[7]