37-051-24544

Well Details

Well ID: 37-051-24544
Loading map...
Country: United States
State: Pennsylvania
County: Fayette
Municipality: Perry Township
Operator Name: CHEVRON APPALACHIA LLC
Well Pad ID: 146175
Farm/Lease Name: PORTER-NAYLOR UNIT 27H
License Status: Active
Spud Date: 2012-11-14
Permit Date: 2012-10-22
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.125561
Longitude: -79.761031

For data sources see[1][2][3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-01-26 2014-05-16 8053 5,861,580.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Base Fluid Chevron Carrier/Base Fluid Water (Including Mix Water Supplied by Client) 7732-18-5 100 90.9015 0
EC6486A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00081972 0
J134 Schlumberger Gel Breaker Hemicellulase Enzyme 9012-54-8 100 0.00032727 0
J609 Schlumberger Friction Reducer Ammonium Sulfate 7783-20-2 30 0.00405563 0
Proppant Schlumberger Proppant Crystalline Silica 14808-60-7 100 8.97855 0
Ec6673W Nalco Iron Control Ethylene Glycol 107-21-1 30 0.00074439 0
EC6116A Nalco Biocide Polyethylene Glycol 25322-68-3 60 0.00144994 0
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00072497 0
Dibromoacetonitrile 3252-43-5 5 0.00012083 0
L058 Schlumberger Iron Stabilizer Sodium erythorbate 6381-77-7 100 0.00050578 0
B466 Schlumberger Friction Reducer Ammonium Acetate 631-61-8 6 0.00007037 0
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.00035183 0
Alcohol Ethoxylates Proprietary 5 0.00005864 0
15% Acid Schlumberger Perf Cleanup Hydrocloric Acid 7647-01-0 15 0.0137174 0
J580 Schlumberger Gelling Agent Carboydrate polymer Proprietary 100 0.00519909 0
A264 Schlumberger Iron Control Prop-2-yn-1-ol 107-19-7 10 0.00001297 0
Aliphatic alcohols, ethoxylayed #1 Proprietary 30 0.00003891 0
Aliphatic acids Proprietary 30 0.00003891 0
Methanol 67-56-1 40 0.00005188 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2013 CHEVRON APPALACHIA LLC 0.00 0 0.00 0 0.00 0
2014 CHEVRON APPALACHIA LLC 350,108.00 99 0.00 0 104.00 99
2015 CHEVRON APPALACHIA LLC 798,494.00 365 0.00 0 0.00 0
2016 CHEVRON APPALACHIA LLC 559,862.00 366 0.00 0 0.00 0
2017 CHEVRON APPALACHIA LLC 432,737.00 365 0.00 0 0.00 0
2018 CHEVRON APPALACHIA LLC 357,948.00 365 0.00 0 0.00 0
2019 CHEVRON APPALACHIA LLC 79,417.00 90 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 646.55 Tons LANDFILL 100419
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 3,898.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) 442.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2013 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 501.52 Tons LANDFILL 100592
2013 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 3,650.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 1,344.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Drill Cuttings (in Tons) 1.06 Tons LANDFILL 100592
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 7.27 Tons LANDFILL 76-00-08
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 11.78 Tons LANDFILL 100172
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 1,529.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2014 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 14,126.40 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 104.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 0.10 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2014 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 27.05 Tons LANDFILL 100592
2015 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 84.00 Bbl INJECTION DISPOSAL WELL 34-121-23995
2015 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) 3,474.80 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHEVRON APPALACHIA LLC Fracing Fluid Waste (in Barrels) 812.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW001
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 2.53 Tons LANDFILL 073 114 654
2015 CHEVRON APPALACHIA LLC Fracturing Fluid Waste (in Tons) 34.00 Tons STORAGE PENDING DISPOSAL OR REUSE MID0209062814
2016 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 603.83 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW019
2016 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 858.81 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 132.40 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 228.40 Bbl REUSE (AT WELL PAD)
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 224.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Drilling Fluid Waste (in Barrels) RWC 803 24.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 992.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW001
2017 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 22.00 Bbl INJECTION DISPOSAL WELL 34-119-28776
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 37.68 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW019
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 351.00 Bbl REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA
2018 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 128.00 Bbl REUSE (AT WELL PAD)
2019 CHEVRON APPALACHIA LLC Produced Fluid (in Barrels) RWC 802 116.00 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2121875 Primary Facility 2012-08-02 Routine/Complete Inspection No Violations Noted Pre-op Inspection of well site. Perimeter E&S in place and functioning.
2126355 Primary Facility 2012-11-21 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,CONDUCTOR PIPE (30")SET 56' ON (11/16/2012).
2136956 Primary Facility 2013-02-06 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE RIG DRILLING ON AIR @ 371 (TD). RUNNING COAL PROTECTION CASING AND CEMENTING TODAY (2/5/2013). BASKET SET @ 300'.
2136960 Primary Facility 2013-02-05 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE RIG DRILLNG ON AIR @ 264' (TD). RUNNING 1ST WATER PROTECTION CASING AND CEMENTING TONIGHT (2/2/2013).
2136966 Primary Facility 2013-02-01 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE RIG MOVED OVER TO PORTER - NAYLOR 27 - H (1/31/2013). RIGGING - UP AT PRESENT TIME.
2138247 Primary Facility 2013-02-06 Routine/Complete Inspection No Violations Noted Site ID in place, plans in box, E&S in place and functioning. Driller on site.
2140820 Primary Facility 2013-02-14 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE RIG DRILLING ON AIR @ 742' TODAY.
2140824 Primary Facility 2013-02-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE RIG DRILLING ON AIR @ 487' (TD). RUNNING 2ND WATER PROTECTION CASING AND CEMENTING TONIGHT (2/7/2013).
2150947 Primary Facility 2013-02-28 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, KEANE DRILLING ON AIR @ 6412' (TD). RUNNING BRIDGE PLUG AND LOADING WELL WITH OIL BASE MUDD.CAPPING AND MOVING TO PORTER -NAYLOR # 28 - H.
2150955 Primary Facility 2013-02-18 Drilling/Alteration No Violations Noted HORIZOTAL MARCELLUS,KEANE DRILLIMG ON AIR @ 2616' (TD).RUNNING INTERMEDIATE CASING AND CEMENTING TODAY.
2185818 Primary Facility 2013-07-23 Incident- Response to Accident or Event In Compliance with Policy Operator self reported spill of 6 barrels of oil based drill mud all on containment. PIC on site showed me spill and all was in fact on containment and will be sucked up and reused. Area stable, good growth, impoundment had over 2 foot freeboard.
2203283 Primary Facility 2013-07-17 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 MOVING ON PORTER-NAYLOR TODAY.
2203285 Primary Facility 2013-07-26 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, PATTERSON # 334 DRILLING ON FLUID @ 14,168' (TD). RUNNING 51/2" PROD. CASING AND CEMENTING TONIGHT.
2244963 Primary Facility 2014-02-13 Administrative/File Review In Compliance with Policy SPILL Operator self reported a spill on 1/22/2014, at the Chevron Porter-Naylor 27H well in Perry Twp., Fayette County. The spill was reported by Beth Smock at 14:45, the incident occurred at 13:42 the same day.
2253489 Primary Facility 2014-03-05 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, THE FRAC JOB IS SUSPENDED UNTIL FURTHER NOTICE.
2263161 Primary Facility 2014-03-26 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS,OPERATIONS SUSPENDED, ON STAND DOWN UNTIL FURTHER NOTICE. FRAC CREW INCOUNTER ISSUES DURING STIMULATION.
2265504 Primary Facility 2014-04-25 Site Restoration Outstanding Violations - No Viols Req'd On 4/25/2014, I performed an inspection of Chevron Appalachia's Porter Naylor Unit 27H, 28H, 37H, 38H, 39H well site in Perry Twp., Fayette County. The reason for the inspection was that the operator is requesting an extension to the restoration date for the site.There are 5 wells on the site. One well is yet to be fracked. This is part of the reason for the extension requqest and the need to retain the water impoundment until that well is fracked. The impoundment had over two feet of freeboard and the water was being circulated today.
2274531 Primary Facility 2014-05-08 Drilling/Alteration No Violations Noted HORIZONTAL MARCELLUS, COMPLETION OF CLEANING WELL BORE TO PROCEED WITH STIMULATION PROCEDURES..
2320703 Primary Facility 2014-11-12 Routine/Complete Inspection No Violations Noted
2339358 Primary Facility 2015-01-27 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed, well was equipped for production. Brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2373167 Primary Facility 2015-05-15 Routine/Complete Inspection No Violations Noted
2384270 Primary Facility 2015-06-23 Routine/Complete Inspection No Violations Noted On 06/23/15 at approximately 1000 hours I conducted a routine complete inspection of the Porter-Naylor Unit. The Act 9 sign was in place and all required documents were present at the site. The site was being hydroseeded and BMPs appear to be in good condition and maintained. There were no violations noted at the time of inspection
2421485 Primary Facility 2015-07-28 Routine/Complete Inspection No Violations Noted On 07/28/15 at approximately 1500 hours I conducted a routine inspection of the site. The Act 9 sign was in place and all required documents were present at the site. The wells appeared to be in good condition. The site had been seeded approximately one month earlier. It was clear that the land owner had used heavy machinery to create a motocross type track on the site (see photos). The earth disturbance occurred in the lower section of the site and what appeared to be jumps were built over top of the reclaimed sediment trap.
2478942 Primary Facility 2016-04-25 Routine/Complete Inspection No Violations Noted On 04/25/16 at approximately 0800 hours I conducted a routine complete inspection of the site. The Act 9 sign was in place and all required documents were present in the mail box. The site contained disturbed areas that have been documented to be the result of the land owner causing third party impact Insp ID # (2421484). At the time of inspection the motocross type track was still present at the site (see photographs). The areas not impacted by a third party exhibited good vegetative cover (see photographs). There were no violations observed at the time of inspection.


Porter Naylor

27H 051-24544 28H 051-24545 37H 051-24546 38H 051-24547 39H 051-24548

2510393 Primary Facility 2016-06-17 Routine/Complete Inspection No Violations Noted

On 06/17/16 at approximately 1030 hours I conducted a CEI at the Porter Naylor site. The Act 9 sign was in place and all required documents were present at the site.

On 02/04/14 the Department conducted an inspection of the site and found violations of chapter 105 for failing to have the GP-7 permit present at the crossing and for failing to construct the stream crossing as approved. A violation of 102.8 was cited for failure to obtain PCSM for a paved apron at the access road entrance.

At the time of inspection the paved apron had been removed and the stream crossing had been reworked to be compliant with the approved GP-7. Chevron has corrected the violations cited in the 02/04/14 inspection report. There were no violations observed at the time of inspection.

2647796 Primary Facility 2017-09-28 Site Restoration No Violations Noted A site restoration inspection was conducted by this WQS and WQSS John Carson in response to an NOT submittal by Chevron. The Act 9 sign was in place and all documents were present at the site. Chevron had previously documented and provided evidence of third party impacts at the site. Third party impacts were observed at the time of inspection (see photographs). The remainder of the site not impacted by third party actors was well vegetated and met and exceeded 70% uniform vegetative cover. The site meets the requirements for permit termination. The NOT is approved.
2712907 Primary Facility 2018-04-02 Routine/Complete Inspection No Violations Noted Well appears properly outfitted for production. On site inspection shows no apparent violations. NOVIO
2852967 Primary Facility 2019-03-08 Routine/Complete Inspection No Violations Noted Well appears to be in good working condition.

For data sources see[7]

References