If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-085-20382 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.754479363,"lon":-81.21768772,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Lake | |
Municipality: Painesville Township | |
Operator Name: MIHALIK PAUL | |
Well Pad ID: | |
Farm/Lease Name: TRESGER | |
License Status: Producing | |
License Date: 1982-07-14 | |
Spud Date: 1982-08-20 | |
Spud Drilling Contractor: H.L.H. DRLG | |
Final Drill Date: 1982-08-24 | |
Well Total Depth: 2990 ft | |
Configuration: Vertical | |
Latitude: 41.754479363 | |
Longitude: -81.21768772 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-07-14 | 858 DRILLEX INC GeoDate 7/14/82 |
Oil and Gas | 1982-07-14 | Issued Date 7/14/82 Expired Date 1/1/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 02990 Proposed Drill Depth 02990 |
Original Spud | 1982-08-20 | PERMIT EXPIRED. |
Completed | 1982-08-24 | PERMIT EXPIRED. |
Reached Total Depth | 1982-08-24 | PERMIT EXPIRED. |
Construction Permit Expires | 1983-01-01 | PERMIT EXPIRED. |
Completion Report Received | 1985-01-10 | PERMIT EXPIRED. |
Change of Owner | 2003-10-06 | Operator changed from 858, DRILLEX INC to 7531, MIHALIK PAUL |
Record Last Modified | 2017-02-15 | PERMIT EXPIRED. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 2880 | 2946 | 0 |
2006-09-11 | 2890 | 2945 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1200 Bbl | 40000 | FRAC: H2O,SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | DRILLEX INC | 10646 | 0 | 0 |
1985 | DRILLEX INC | 884 | 0 | 365 |
1986 | DRILLEX INC | 2784 | 0 | 365 |
2004 | MIHALIK PAUL | 0 | 0 | 0 |
2005 | MIHALIK PAUL | 50 | 0 | 10 |
2006 | MIHALIK PAUL | 0 | 0 | 0 |
2008 | MIHALIK PAUL | 0 | 0 | 0 |
2009 | MIHALIK PAUL | 0 | 0 | 0 |
2010 | MIHALIK PAUL | 0 | 0 | 0 |
2011 | MIHALIK PAUL | 0 | 0 | 0 |
2012 | MIHALIK PAUL | 0 | 0 | 0 |
2013 | MIHALIK PAUL | 212 | 0 | 30 |
2014 | MIHALIK PAUL | 379 | 0 | 60 |
2015 | MIHALIK PAUL | 209 | 0 | 30 |
2016 | MIHALIK PAUL | 128 | 0 | 30 |
2017 | MIHALIK PAUL | 206 | 0 | 30 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | DRILLEX INC | Brine | 280 | 0 |
1985 | DRILLEX INC | Brine | 165 | 365 |
1986 | DRILLEX INC | Brine | 0 | 365 |
2004 | MIHALIK PAUL | Brine | 0 | 0 |
2005 | MIHALIK PAUL | Brine | 0 | 10 |
2006 | MIHALIK PAUL | Brine | 0 | 0 |
2008 | MIHALIK PAUL | Brine | 0 | 0 |
2009 | MIHALIK PAUL | Brine | 0 | 0 |
2010 | MIHALIK PAUL | Brine | 0 | 0 |
2011 | MIHALIK PAUL | Brine | 0 | 0 |
2012 | MIHALIK PAUL | Brine | 0 | 0 |
2013 | MIHALIK PAUL | Brine | 23 | 30 |
2014 | MIHALIK PAUL | Brine | 2 | 60 |
2015 | MIHALIK PAUL | Brine | 4 | 30 |
2016 | MIHALIK PAUL | Brine | 0 | 30 |
2017 | MIHALIK PAUL | Brine | 0 | 30 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL14414 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
1014540150 | 2014-12-17 | UrbanProduction Wells | No Violations | I inspected the location of this producing unit as part of routine inspection activity. The wellhead and battery are located in an un-developed portion of the former Fairway Pines Golf Club. At the wellhead there is valve-tree and concoil system. The battery is comprised of 1 100-barrel production tank and separator. The well elements are in good repair with no signs of leakage or problems. ID signage and secondary containment are present at the battery. Load-outs are bull-plugged. According to the signage, the battery is shared with the #9 (#2-0383) and the # 10 (#2-384) units. There is no ID at these wellheads. I asked Paul Mihalik to begin working on getting signage at the wellheads. |
1269889438 | 2010-03-18 | Production Wells | Violations Noted | The Lake County SWCD office received a complaint regarding the well. A resident was concerned about fluids leaking from the facility.
An inspection found the well to be incapable of production and without identification. At the time of inspection, the production equipment was not leaking fluids. Post an ID with the following information: owner, lease name, well number, county, permit number, and an emergency telephone number. Plug or produce the well. |
1352148943 | 2010-06-25 | Production Wells | No Violations | The well is in compliance. |
1816705987 | 2017-06-12 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well is located on an otherwise undeveloped parcel. At the time of this inspection, I observed the following: a wellhead plunger-lift system in an open meadow area with associated tank battery (one 100-barrel steel stock tank and separator) that is shared with the #2-0383 and #2-0384 wells. The load-line valve was secure and plugged. The tank lid was closed and sealed. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas around the wellhead and battery and found no signs of impact or problems. The access road to the well and battery were in good condition. Production reports were current and there was no indication in available electronic records of any deficiencies with bonding or insurance. |
2096656780 | 2018-11-28 | UrbanProduction Wells | No Violations | I conducted an inspection on this well. At the time of this inspection, the well was equipped with a Concoil plunger lift assembly and not in production. The tank battery consisted of one 100 BBL tank and a heater treater separator. Valves on the separator were open and the chart showed production. Wells 2-0383 and 2-0384 were also produced into this tank battery. The 100 BBL tank was diked but the separator was located outside of the diked area. Legible identification was located at the well and tank battery. The lease access was stable. No violations observed. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1269889438 | US-OH-107228 | 2010-04-28 | Failure to legibly identify well | |
1269889438 | US-OH-107229 | 2010-03-29 | Well shall be plugged |
For data sources see[9]