Well Details

Well ID: 34-085-20382
Loading map...
Country: United States
State: Ohio
County: Lake
Municipality: Painesville Township
Operator Name: MIHALIK PAUL
Well Pad ID:
Farm/Lease Name: TRESGER
License Status: Producing
License Date: 1982-07-14
Spud Date: 1982-08-20
Spud Drilling Contractor: H.L.H. DRLG
Final Drill Date: 1982-08-24
Well Total Depth: 2990.00 ft
Configuration: Vertical
Latitude: 41.750000
Longitude: -81.210000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1982-07-14 858 DRILLEX INC GeoDate 7/14/82
Oil and Gas 1982-07-14 Issued Date 7/14/82 Expired Date 1/1/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 02990 Proposed Drill Depth 02990
Original Spud 1982-08-20 PERMIT EXPIRED.
Completed 1982-08-24 PERMIT EXPIRED.
Reached Total Depth 1982-08-24 PERMIT EXPIRED.
Construction Permit Expires 1983-01-01 PERMIT EXPIRED.
Completion Report Received 1985-01-10 PERMIT EXPIRED.
Change of Owner 2003-10-06 Operator changed from 858, DRILLEX INC to 7531, MIHALIK PAUL
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 2880 2946 0
2880 2946 0
2006-09-11 2890 2945 21
2890 2945 21
2880 2946 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1200 Bbl 40000 FRAC: H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DRILLEX INC 10646.00 0.00 0
1985 DRILLEX INC 884.00 0.00 365
1986 DRILLEX INC 2784.00 0.00 365
2004 MIHALIK PAUL 0.00 0.00 0
2005 MIHALIK PAUL 50.00 0.00 10
2006 MIHALIK PAUL 0.00 0.00 0
2008 MIHALIK PAUL 0.00 0.00 0
2009 MIHALIK PAUL 0.00 0.00 0
2010 MIHALIK PAUL 0.00 0.00 0
2011 MIHALIK PAUL 0.00 0.00 0
2012 MIHALIK PAUL 0.00 0.00 0
2013 MIHALIK PAUL 212.00 0.00 30
2014 MIHALIK PAUL 379.00 0.00 60
2015 MIHALIK PAUL 209.00 0.00 30
2016 MIHALIK PAUL 128.00 0.00 30
2017 MIHALIK PAUL 206.00 0.00 30

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DRILLEX INC Brine 280 0
1985 DRILLEX INC Brine 165 365
1986 DRILLEX INC Brine 0 365
2004 MIHALIK PAUL Brine 0 0
2005 MIHALIK PAUL Brine 0 10
2006 MIHALIK PAUL Brine 0 0
2008 MIHALIK PAUL Brine 0 0
2009 MIHALIK PAUL Brine 0 0
2010 MIHALIK PAUL Brine 0 0
2011 MIHALIK PAUL Brine 0 0
2012 MIHALIK PAUL Brine 0 0
2013 MIHALIK PAUL Brine 23 30
2014 MIHALIK PAUL Brine 2 60
2015 MIHALIK PAUL Brine 4 30
2016 MIHALIK PAUL Brine 0 30
2017 MIHALIK PAUL Brine 0 30

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2096656780 2018-11-28 0:00 UP No Violations
000PL14414 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
1014540150 2014-12-17 UrbanProduction Wells No Violations I inspected the location of this producing unit as part of routine inspection activity. The wellhead and battery are located in an un-developed portion of the former Fairway Pines Golf Club. At the wellhead there is valve-tree and concoil system. The battery is comprised of 1 100-barrel production tank and separator. The well elements are in good repair with no signs of leakage or problems. ID signage and secondary containment are present at the battery. Load-outs are bull-plugged. According to the signage, the battery is shared with the #9 (#2-0383) and the # 10 (#2-384) units. There is no ID at these wellheads. I asked Paul Mihalik to begin working on getting signage at the wellheads.
1269889438 2010-03-18 Production Wells Violations Noted The Lake County SWCD office received a complaint regarding the well. A resident was concerned about fluids leaking from the facility.

An inspection found the well to be incapable of production and without identification. At the time of inspection, the production equipment was not leaking fluids.

Post an ID with the following information: owner, lease name, well number, county, permit number, and an emergency telephone number.

Plug or produce the well.

1352148943 2010-06-25 Production Wells No Violations The well is in compliance.
1816705987 2017-06-12 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. The well is located on an otherwise undeveloped parcel. At the time of this inspection, I observed the following: a wellhead plunger-lift system in an open meadow area with associated tank battery (one 100-barrel steel stock tank and separator) that is shared with the #2-0383 and #2-0384 wells. The load-line valve was secure and plugged. The tank lid was closed and sealed. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas around the wellhead and battery and found no signs of impact or problems. The access road to the well and battery were in good condition. Production reports were current and there was no indication in available electronic records of any deficiencies with bonding or insurance.
2096656780 2018-11-28 UrbanProduction Wells No Violations I conducted an inspection on this well. At the time of this inspection, the well was equipped with a Concoil plunger lift assembly and not in production. The tank battery consisted of one 100 BBL tank and a heater treater separator. Valves on the separator were open and the chart showed production. Wells 2-0383 and 2-0384 were also produced into this tank battery. The 100 BBL tank was diked but the separator was located outside of the diked area. Legible identification was located at the well and tank battery. The lease access was stable. No violations observed.
PL14414 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1269889438 US-OH-107228 2010-04-28 Failure to legibly identify well
1269889438 US-OH-107229 2010-03-29 Well shall be plugged

For data sources see[9]

References