If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-055-20983 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.537321766,"lon":-81.11159865,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Claridon Township | |
Operator Name: BIG SKY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: SCHLOSS-HANS | |
License Status: Producing | |
License Date: 1984-09-21 | |
Spud Date: 1985-03-05 | |
Spud Drilling Contractor: EDCO DRLG | |
Final Drill Date: 1985-03-10 | |
Well Total Depth: 3954 ft | |
Configuration: Vertical | |
Latitude: 41.537321766 | |
Longitude: -81.11159865 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1984-09-21 | 254 EDCO DRILLING & PRODUCING GeoDate 9/21/84 |
Oil and Gas | 1984-09-21 | Issued Date 9/21/84 Expired Date 3/20/85 Acres 0040000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03954 Proposed Drill Depth 03954 |
Original Spud | 1985-03-05 | IP. OIL = 1/2 BBL. |
Completed | 1985-03-10 | IP. OIL = 1/2 BBL. |
Reached Total Depth | 1985-03-10 | IP. OIL = 1/2 BBL. |
Construction Permit Expires | 1985-03-20 | IP. OIL = 1/2 BBL. |
Completion Report Received | 1985-04-22 | IP. OIL = 1/2 BBL. |
CO | 1993-10-22 | 1111 MERIDIAN ENERGY COMPANY GeoDate 9/21/84 |
Change of Owner | 2018-03-22 | Operator changed from 1111, MERIDIAN ENERGY COMPANY to 1333, BIG SKY ENERGY INC - WELL TRANSFER CORRECTION PER LEGAL. INCORRECT COUNTY LISTED BY OWNER ON 3/22/2018 CM. |
Record Last Modified | 2018-03-22 | IP. OIL = 1/2 BBL. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3794 | 3907 | 0 |
2006-09-11 | 3815 | 3858 | 41 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1600 Bbl | 50000 | |||
ACID | 0 | 250 Gal | 0 | FRAC;H2O,SAND,N2 | ||
N2 | 0 | 180 Mscf | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0037264359 | 2015-12-01 | Production Wells | No Violations | My inspection found the company has recently brought in a swab rig and removed a 100 BBL full of oil after the maintenance was completed. The well has pressured up to over 750 psi. The well tender is currently replacing the flow line. Dominion currently has the sales meter shut in so the company is unable to sell gas. Once Dominion allows the company to sell the well will be put back into production. The company that owns the property has stacked lime stone up next to the tank battery and well and it is beginning to spill over the dike and into the tank battery. The dike wall on the West side of the tank battery has been removed by the property owners equipment. I have contacted Ralph Kyanko for Kokosing Materials and spoke with him about repairing the dike. We are to meet on location this month to discuss issues about the well. |
0095200150 | 2011-03-08 | Production Wells | No Violations | 4.5 inch casing is under water. Valve is at the surface of the water and was visible. The valve was closed. Operator has attached a 2 inch pipe to the top of the valve. Gas was bubbling up around the casing. Bubbling was taking place approximately 2 feet around the wellhead under water. Tested water for Cl-, no Cl- noted. Well head was not connected to the tank battery in noticeable manner. Black plastic pipe was coiled at the tank battery location. Separator valves were closed. |
0136459528 | 2009-12-02 | Production Wells | No Violations | Tank battery has been roughed in, separator and 100bbl tank is on site. ID sign is not posted on the battery or separator. Well head is below grade, a pipe with a valve extends out of the ground with a traffic cone on it. Gas is bubbling up around the location of the well head. There is approximately 6 inches of water on top of the ground where the well head is. Pulled water sample and test for CL-, 1.8 on the low range CL tab, approximately 65ppm of CL, water is fresh water. 2 inch black plastic tubing was on location in a roll. Well is not plumbed into the tank battery at this time. Oil covered pipes where laying next to the tank battery, pipes appeared to be from the pump jack, that had been on the well. |
0149547266 | 2011-03-10 | Production Wells | No Violations | On site with Steve Ochs, no change at well site since last inspection. 100Bbl tank is empty. Well head is not connected to the separator. Well is leaking gas to the surface, there was bubbling through the water standing around the well. Valve on the well was closed. Pictures taken during inspection. Black plastic pipe was coiled and stocked next to the separator. Chart has rusted off of the separator and was in the meter box. Pipe coming out of the ground on the west side of the separator was shut off. |
0234175114 | 2013-08-21 | Production Wells | No Violations | On site with Inspector Kevin Perry. Operator has built a dike around the tank battery and the well head. Trencher has been repaired and moved away from the well. Tank battery, ladder has been replaced on the 100BBl tank. No indication of the well leaking at the time of inspection. Identification sign has been posted. |
0266784614 | 2009-10-21 | Production Wells | No Violations | Well is leaking at the swedge. Well is not in production. Tank battery is not hooked to the well. Swedge has been threaded onto the well head. On site with Jay Cheslock. |
0428350689 | 2012-07-11 | Production Wells | No Violations | My inspection today found the well shut in at the wellhead. The operator has completed the following work on site: The operator replaced the existing flow line with a flow line above ground. Approximately 35 feet of the flow line is a steel line and the last 15 feet of the line is a high pressure flexible line. Flow line valve was closed at the separator. Meter box has been attached to the separator. |
0442658959 | 2011-10-04 | Production Wells | No Violations | Well is not in production. Sales line has not been connected to the separator. Production tank and separator are not connected. Chart meter is not connected to the separator. The two 1/4 inch lines from the chart box to the separator are disconnected. Flow line is shut off before the separator. Sales line installation has began. Operator has installed sales line within 150 feet of the Dominion tap. South end of the sales line is visible in the lawn. Dominion meter has been roughed in. |
0552336913 | 2014-02-12 | Production Wells | No Violations | My inspection found the company is still producing the well. The valve is open on the wellhead leading to the flow line. The valve is open on the flow line leading into the separator. The valve on the sales line leading out of the separator is open. The valves on the meter run by the entry to the location are open. No other changes to the location since my last inspection. |
0635141138 | 2009-07-22 | Production Wells | No Violations | Well is not in production. Tank battery has been installed north of the well head. Well head has been knocked off by a loader accident. Oil and brine sprayed area to the west of the well. Grass has been mowed, area is scalded. Waiting to see if vegetation re-establishes itself. |
0666320426 | 2010-09-20 | Production Wells | No Violations | No change on site. Wellhead has a valve on it and is leaking around casing, bubbling was evident coming up through the standing water around wellhead. Tank battery has not been hooked up. Pictures taken this day. Contacted Supervisor Jay Cheslock regarding well. |
0864179909 | 2012-01-11 | Production Wells | No Violations | The valves are shut off at the well head. The meter run has been roughed in. The tank battery equipment has been moved to meet spacing. |
1021385779 | 2009-07-14 | Production Wells | No Violations | on site to over see clean-up of oil sprayed grass. Flagged area to mow and advised company to scrape-up oil coated gravel fines and stock pile so asphalt plant can recycle the material. |
1168181109 | 2013-08-21 | Production Wells | No Violations | My inspection found the trencher had been removed from inside the tank battery but was still on location. A dike was established around the tank battery. An identification sign was on the production tank. The tank ladder was no longer laying on the ground and was attached to the production tank. The spacing issues have not been corrected. The flow line still needs to be buried. |
1226070832 | 2008-11-07 | Production Wells | Violations Noted | Well has had no production reported since 2001. Well valves are shut off. Sucker rods are rusted. 210 BBL tank, poly tank and mechanical separator in battery. No charts in separator. Hammer union disconnected before separator. Bottom of 210 tank appears to be leaking, oil staining in grass around tank. Tank has fluid in it approximately 1/4 full, fluid needs removed. ID sign needs replaced. Well needs either put back into production within 90 days or plugged within 90 days. Well needs identification ID sign replaced by 12/15,2008. 210 BBL tank needs emptied by 12/07/2008. 210 Storage tank needs removed or repaired by 12/10/2008. Well either needs plugged or put back into production by 02/07/2009. If well can not be plugged |
1229023257 | 2008-12-11 | Production Wells | No Violations | Big Sky service rig on site. Operator is pulling rods and tubing from the well. Tank battery has been removed. Operator is planning on plugging well next week. Operator will need a permit to plug before they plug well. |
1272045377 | 2010-04-21 | Production Wells | No Violations | No change on site. Well is not in production. On site with Jay Cheslock. |
1277220500 | 2010-06-21 | Administrative Inspection | No Violations | Phone call from Doug Holthus counsel for Kokosing Materials, calling regarding status of well. Doug informed me that there hasnt been an injunction issued from the courts. Operator could have been working towards putting well back into production. Operator may be in discussion with Broad Street Energy and Northwood Energy to produce well into their sales line. Called Steve Chomos from Broad Street, there was a discussion no agreement was made. Called Northwood Energy, left message. Doug stated that he has contacted Jean Bruner at 14864 Mayfield Road in regards to domestic supply. Jean has not been receiving domestic supply from well. |
1292254389 | 2010-11-30 | Production Wells | No Violations | No change on location. Well head has a valve on it. Gas is bubbling up around pipe. Casing is under water. Tank battery is not hooked up. Well is not in production. Spoke to Bob from Big Sky 12/06/2010: Working with Dominion on getting a meter run installed. |
1295444933 | 2011-01-18 | Production Wells | No Violations | Lease road and site was covered with 20 plus inches of snow. Site was snow covered. It did not appear there was any change on site. |
1300287419 | 2011-03-16 | Production Wells | No Violations | No change on site. Spacing will need to be corrected before well is put into production. It is 45 feet between the well and the separator. Less then 10 feet between production tank and separator. Dike will need to be constructed around the wellhead. There was gas bubbling from the ground through the water around the well head. The area of bubbling was approximately 2 feet in diameter. Gas odor was noted. |
1308925887 | 2011-06-23 | Production Wells | No Violations | Operator has connected a flexible line from the well head to the flow line. The flow line is connected to the separator. Separator is connected to a sales line. Valves are closed. Bubbling around the well head was present. No identification sign posted. |
1317757744 | 2011-09-16 | Production Wells | No Violations | No change at the wellhead. Valve on the wellhead is open, valve at the separator is closed. Separator is not attached to sales line. Production tank is not connected to the separator. Operator has installed sales line under Kokosings haul road. The sales line then runs south adjacent to the road. Meter run has been partially installed. Sales line is not connected to tap adjacent to State Route 322. Pictures taken this day. |
1318530183 | 2011-10-13 | Production Wells | No Violations | Well is not in production and valve on the wellhead is shut off. Gas is bubbling up around the valve that is at ground level. Sales line has not been connected to the separator, connection threads have been installed on the north end of the sales line. Production tank has been connected to the separator. Spacing between the separator and the production tank has been corrected. South end of the sales line has not been connected to the tap. Sales line is above ground within 50 of the tap. Chart is not connected to the separator and 1/4 lines from the meter box to the separator are disconnected at the separator. Operator has stated that he is going to produce the well on a Con-Coil and I called Bob on Oct 3, 2011 at 12:32pm leaving a message requesting information on when that was going to take place. Have not received return call or information on whenCon-Coil is to be installed. A well leaking gases into the atmosphere is in non-compliance with 1509.12. Operator needs to take corrective actions to repair leak. The well has had no reported production since 2000. |
1321365233 | 2011-11-14 | Production Wells | No Violations | Jamie from Big Sky is on site installing pressure regulators at the meter run. |
1370527423 | 2013-06-06 | Production Wells | No Violations | My inspection found the well to be plumbed up from the 4.5 casing and reduced to 2 plumbed directly into the flow line. The flow line is rubber and then is plumbed into a 2 metal line. The flow line is running on top of the ground. The tank battery consists of a 100 BBL production tank and a mechanical separator. There is no identification on the well. The lease road is stable. Production has not been reported in 2011 and 2012. There is a trencher that has been sitting on the location for a year. I spoke with Jamie Cambell about having the flow line buried, the trencher removed from the location, getting an ID sign on the well, and cleaning up the location. He will find out about the production and report back to me. |
1375895416 | 2013-08-01 | Production Wells | Violations Noted | My inspection found the well to be plumbed up from the 4.5 casing and reduced to 2 plumbed directly into the flow line. The flow line is rubber and then is plumbed into a 2 metal line. The flow line is running on top of the ground. The tank battery consists of a 100 BBL production tank and a mechanical separator. There is no identification on the well. The lease road is stable. Production has not been reported in 2011 and 2012. Production was also not reported for the years 2001 to 2010. There is a trencher that has been sitting on the location for a year. Myself and my supervisor Tom Hill have made numerous attempts to get the issues remedied. The flow line needs buried. The spacing between the wellhead and the separator needs to be made and the spacing between the separator and the production tank needs corrected. The proper containment around the tank battery needs to be established. The trencher cannot be stored on the location. The proper identification needs to be visible on the tank battery. Production needs to be reported for 2011 and 2012. These actions need to be performed within 30 days of receiving this notice. |
1389275375 | 2014-01-09 | Production Wells | No Violations | My inspection found the ladder for the production tank has been knocked off of the tank. I will contact the company about having the ladder reattached to the production tank. The well was producing while I was on location. It has a production cycle of 3 minutes every 8 hours. There has been no other changes since my last inspection. |
1393929876 | 2011-06-24 | Production Wells | No Violations | On site with Jim Bailey who is attempting to flow the well into the production tank. After discussing the procedure with Supervisor Rick Simmers, Rick and I were in agreement, that this method of production is not approved. Blowing a well down and flowing it into a production tank using a flexible line is not an standard method of producing a well and is not allowed. Well is not in currently in production and equipment spacing is not correct. The distance between the separator and well head is 48. The distance between separator and production tank is 5.4. The distance between separator and wellhead must be 50 feetand the distance between a mechincal separator and production tank must be 50 feet. Per Jim, the sales line runs north then east towards the railroad bed and connects to a Broad Street sales line. Also, there is no agreement between companies to sell into their line. The operator is planning on running a new sales line south and connecting it to an existing East Ohio line. |
1437375801 | 2013-09-25 | Production Wells | No Violations | My inspection today found the flow line has been buried. The trenching machine has been removed from the location. |
1442467094 | 2008-11-07 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 1226070832 Well has had no production reported since 2001. Well valves are shut off. Sucker rods are rusted. 210 BBL tank, poly tank and mechanical separator in battery. No charts in separator. Hammer union disconnected before separator. Bottom of 210 tank appears to be leaking, oil staining in grass around tank. Tank has fluid in it approximately 1/4 full, fluid needs removed. ID sign needs replaced. Well needs either put back into production within 90 days or plugged within 90 days. Well needs identification ID sign replaced by 12/15,2008. 210 BBL tank needs emptied by 12/07/2008. 210 Storage tank needs removed or repaired by 12/10/2008. Well either needs plugged or put back into production by 02/07/2009. If well can not be plugged |
1650965355 | 2011-08-19 | Production Wells | No Violations | Dominion representative Fletcher Molden and Geneva Pipe on site installing the tap on Dominions sales line. Jim Bailey on site for Meridian Energy. Ralph Kyanko on site for Kokosing, Land owner whos property the tap was going on was on site, Jean Bruner. Geneva pipe installed tap, check valve and valve this day. Jim was informed if he starts work on the Kokosing property the Sheriff would be contacted to remove them from property for trespassing. Deputy Sheriff on site in the after noon. It was mutually decided that the matter of the validity of the lease is a civil matter. Decision to continue work is up to the company. Jim needed parts to start work on the sales line will start work next week. |
1772336070 | 2009-07-21 | Production Wells | No Violations | Oil spill removed.In compliance. |
1934707527 | 2012-02-06 | Production Wells | No Violations | No change on site from last inspection. Well is not in production. Contacted Jeff from Big Sky 02/14, waiting for East Ohio to test meter. Service rig is on another location and cant be moved. Operator is going to install a con-coil well, once rig is available. |
2034635453 | 2013-06-27 | Production Wells | No Violations | I was on location with Tom Hill to check on the status of the work that had been requested for Meridian Energy to perform. The company has yet to have an identification sign placed on the location. The flow line has not been buried to the proper depth. The trenching machine is still sitting on location. None of the actions requested have been performed. |
2107763762 | 2011-08-22 | Production Wells | No Violations | Jim Bailey on site running sales line to Dominion Line. Operator has installed 500 of sales line. Operator was backfilling trench at the time of inspection. Operator was reminded that the wells spacing needs to be corrected before the well goes into production. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1226070832 | US-OH-106082 | 2013-08-21 | Well insufficiently equipped to prevent escape of oil and gas | |
1226070832 | US-OH-106083 | 2013-08-21 | Failure to legibly identify well | |
1226070832 | US-OH-106084 | 2013-08-21 | Well shall be plugged | |
1375895416 | US-OH-111146 | 2014-02-24 | Failure to properly bury pipeline | |
1375895416 | US-OH-111147 | 2014-02-24 | Failure to legibly identify well | |
1375895416 | US-OH-111148 | 2014-02-24 | Dike or pit not able to prevent escape of brine or other wastes | |
1375895416 | US-OH-111149 | 2014-02-24 | Failure to meet tank battery setbacks from a well | |
1375895416 | US-OH-111150 | 2014-02-24 | Statement of annual production not filed | |
1442467094 | US-OH-112864 | 2013-11-04 | Well shall be plugged |
For data sources see[9]