{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.718406196,"lon":-82.68338717,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Richland | |
Municipality: Troy Township | |
Operator Name: RIVER VALLEY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: ELLIOTT UNIT | |
License Status: Final Restoration | |
License Date: 2004-07-06 | |
Spud Date: 1999-11-30 | |
Spud Drilling Contractor: CENTURY WELL SERVICES,INC | |
Final Drill Date: 1999-12-07 | |
Well Total Depth: 1435 ft | |
Configuration: Vertical | |
Latitude: 40.718406196 | |
Longitude: -82.68338717 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 1999-11-26 | Proposed Formations:LOCKPORT, Issued Date:11/26/99, Expired Date:11/25/2000 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:EOUT |
Original Spud | 1999-11-30 | RBDMS Rec |
Completed | 1999-12-07 | RBDMS Rec |
Reached Total Depth | 1999-12-07 | RBDMS Rec |
Completion Report Received | 2000-04-10 | RBDMS Rec |
Change of Owner | 2001-10-22 | Operator changed from 6227, HOUGHTON INVESTMENTS, L.L.C. to 7077, D T ATHA INC |
APP | 2004-07-06 | Proposed Formations:LOCKPORT, Issued Date:7/6/2004, Expired Date:7/6/2005 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2005-06-15 | RBDMS Rec |
Construction Permit Expires | 2005-07-06 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
Not Treated | 0 | 0 | 0 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | HOUGHTON INVESTMENTS LLC | 2542 | 0 | 0 |
2001 | HOUGHTON INVESTMENTS LLC | 1129 | 0 | 365 |
2002 | RIVER VALLEY ENERGY INC | 510 | 0 | 365 |
2003 | HOUGHTON INVESTMENTS LLC | 0 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2000 | HOUGHTON INVESTMENTS LLC | Brine | 1087 | |
2001 | HOUGHTON INVESTMENTS LLC | Brine | 653 | 365 |
2002 | RIVER VALLEY ENERGY INC | Brine | 0 | 365 |
2003 | HOUGHTON INVESTMENTS LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0002773471 | 2001-06-20 | Production Wells | No Violations | Major gas leaks fixed, still has a small leak at the 41/2 to tubing connection. Id posted. |
0003273475 | 2001-07-12 | Production Wells | No Violations | Chk well for gas odors. Still has a small leak at the tubing slips, need to tighten wellhead ring. 07/12/2001 at 3:26 PM I phoned Bill Atha he was not in I left a message w/ the time and a number to call. 07/16/2001 at approx 2:15 pm Bill called me at |
0008073523 | 2001-09-13 | Production Wells | No Violations | Gas is leaking from 4.5 to 2 wellhead. Has a strong H2S odder at this time. Houghton Investments its Agents, Assignees and Successors shall make all necessary repairs to prevent the escape of gas from the wellhead. |
0009273535 | 2001-09-26 | Production Wells | No Violations | I talk to Bill Atha, he told me that he had tightened the wellhead and stopped the gas leak. At this time the well is still leaking. |
0026373663 | 2002-06-06 | Production Wells | No Violations | Chk well and storage, OK exept for wellhead. The wellhead is leaking again. Took photo. |
0118343298 | 2005-10-12 | Plug / Plug Back | No Violations | Inspect Location. All equipment has been removed except production line. |
0124381178 | 2007-06-21 | Plug / Plug Back | Violations Noted | Inspect well location. One inch lines and other oil field debris needs to be removed. |
0172287095 | 2001-09-26 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 92 I talk to Bill Atha, he told me that he had tightened the wellhead and stopped the gas leak. At this time the well is still leaking. |
0173507105 | 2007-10-18 | Final Restoration | No Violations | inspect location. Final restoration complete. Release all previous NOVs. |
0520415844 | 2006-12-21 | Plug / Plug Back | No Violations | Inspect location for final restoration . Production lines have not been removed. |
0624831164 | 2001-09-26 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 92 I talk to Bill Atha, he told me that he had tightened the wellhead and stopped the gas leak. At this time the well is still leaking. |
0764040351 | 2001-06-20 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 27 Major gas leaks fixed, still has a small leak at the 41/2 to tubing connection. Id posted. |
0807108355 | 2003-08-11 | Production Wells | No Violations | Well inspection. ID is present but faded. Well is leaking gas from back side of 4.25 inch casing. Chart recorder has been removed. Well shut in. Steel well head is significantly rusted. |
1109785119 | 2005-03-02 | Production Wells | No Violations | Follow up of previous NOV.Casing gas not leaking, repairs made. Could hear leak before.No audible or visual leaks. Could smell H2S odor. Casing and tubing is beginning to show signs of metal decay due to H2S gas. |
1134080839 | 2005-06-13 | Plug / Plug Back | No Violations | Bottom plug set. Release parmaco packer pull 4.5 till locked in well at 1062 feet. Total of 367.9 feet pulled. Bull head bottom plug. |
1210i18519 | 2001-06-15 | Production Wells | No Violations | Well inspection result of complaint (Linda Taylor). ID posted but faded. Gas leak at fitting on separator 1/4 inch line from separator to murphy switch. Small leak of raw gas. ( H2S). Wellhead leaking from casing head strong leak of H2S gas. Gas meter at leak reads 5 on meter. Downwind 15 feet meter reading zero. Stopped at complainants home and explained what we found. Left business card, with Sam and my numbers. This date Sam called Bill Atha and requested Ids remarked and leak repaired. 3 digital photos taken. Accompanied by Inspector Faust. |
1210i26545 | 2001-11-28 | Production Wells | No Violations | This well had a gas odor complaint where well head was leaking. Inspector Faust got the company to tighten the well head. Well head is still leaking. Worst gas odor ( H2S) is coming from the top of the plastic fluid tank. Gas is coming from the fluid line at the separator and entering into the plastic tank. Gas has strong H2S odor and is audible bubbling thru fluid in tank. |
1533024945 | 2002-10-23 | Production Wells | Violations Noted | Well inspection. Identification is inadequate. Surface soils have collapsed around the Well head casing creating a hole three-(3) to four-(4) feet deep. |
1585274658 | 2004-10-04 | Production Wells | No Violations | inspect Well. Plug Application has been received. Closed old NOVs. ID faded. Pipes are rusted and valves froze.
Plug application expires 7/6/05. |
1880210490 | 2005-08-01 | Plug / Plug Back | No Violations | Inspect location. Well plugged, pit closed. Tubing, 4.5 inch pipe, and well head pipe at location. Production Equipment in place. |
2043861760 | 2001-06-20 | Production Wells | Violations Noted | FOLLOW UP TO NOV # 27 Major gas leaks fixed, still has a small leak at the 41/2 to tubing connection. Id posted. |
iDIAN00516 | 2000-08-07 | Preliminary Restoration | No Violations | |
iTOMK00002 | 2000-04-10 | Production Wells | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0124381178 | US-OH-106499 | 2007-07-05 | Failure to remove production equip. within 6 mos. REPLACE | |
0172287095 | US-OH-117087 | 2001-09-13 | Well insufficiently equipped to prevent escape of oil and gas | |
0172287095 | US-OH-117088 | 2001-09-13 | Unlawful venting or flaring of gas | |
0172287095 | US-OH-117089 | 2001-10-19 | Well shall be plugged | |
0624831164 | US-OH-127065 | 2001-09-13 | Well insufficiently equipped to prevent escape of oil and gas | |
0624831164 | US-OH-127066 | 2001-09-13 | Unlawful venting or flaring of gas | |
0624831164 | US-OH-127067 | 2001-10-19 | Well shall be plugged | |
0764040351 | US-OH-128685 | 2001-06-15 | Failure to legibly identify well | |
0764040351 | US-OH-128686 | 2001-06-15 | Unlawful venting or flaring of gas | |
0764040351 | US-OH-128687 | 2002-04-03 | Disposal of muds or cuttings in violation of a rule | |
1533024945 | US-OH-114738 | 2002-10-24 | Failure to legibly identify well | |
2043861760 | US-OH-120802 | 2001-06-15 | Failure to legibly identify well | |
2043861760 | US-OH-120803 | 2001-06-15 | Unlawful venting or flaring of gas | |
2043861760 | US-OH-120804 | 2002-04-03 | Disposal of muds or cuttings in violation of a rule |