X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-139-20711

Well Details

Well ID: 34-139-20711
Loading map...
Country: United States
State: Ohio
County: Morrow
Municipality: Troy Township
Operator Name: RIVER VALLEY ENERGY INC
Well Pad ID:
Farm/Lease Name: ELLIOTT UNIT
License Status: Final Restoration
License Date: 2004-07-06
Spud Date: 1999-11-30
Spud Drilling Contractor: CENTURY WELL SERVICES,INC
Final Drill Date: 1999-12-07
Well Total Depth: 1435.00 ft
Configuration: Vertical
Latitude: 40.710000
Longitude: -82.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1999-11-26 Proposed Formations:LOCKPORT, Issued Date:11/26/99, Expired Date:11/25/2000 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:EOUT
Original Spud 1999-11-30 RBDMS Rec
Completed 1999-12-07 RBDMS Rec
Reached Total Depth 1999-12-07 RBDMS Rec
Completion Report Received 2000-04-10 RBDMS Rec
Change of Owner 2001-10-22 Operator changed from 6227, HOUGHTON INVESTMENTS, L.L.C. to 7077, D T ATHA INC
APP 2004-07-06 Proposed Formations:LOCKPORT, Issued Date:7/6/2004, Expired Date:7/6/2005 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2005-06-15 RBDMS Rec
Construction Permit Expires 2005-07-06 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 0 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2000 HOUGHTON INVESTMENTS LLC 2542.00 0.00 0
2001 HOUGHTON INVESTMENTS LLC 1129.00 0.00 365
2002 RIVER VALLEY ENERGY INC 510.00 0.00 365
2003 HOUGHTON INVESTMENTS LLC 0.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2000 HOUGHTON INVESTMENTS LLC Brine 1087
2001 HOUGHTON INVESTMENTS LLC Brine 653 365
2002 RIVER VALLEY ENERGY INC Brine 0 365
2003 HOUGHTON INVESTMENTS LLC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-118343298 2005-10-12 0:00 PB No Violations
-124381178 2007-6-21 0:00: PB No Violations
-1585274658 2004-10-4 0:00: PW No Violations
-173507105 2007-10-18 0:00 FR No Violations
-1880210490 2005-8-1 0:00:0 PB No Violations
-764040351 2001-6-20 0:00: PW No Violations
-807108355 2003-8-11 0:00: PW No Violations
0002773471 2001-06-20 Production Wells No Violations Major gas leaks fixed, still has a small leak at the 41/2 to tubing connection. Id posted.
0003273475 2001-07-12 Production Wells No Violations Chk well for gas odors. Still has a small leak at the tubing slips, need to tighten wellhead ring. 07/12/2001 at 3:26 PM I phoned Bill Atha he was not in I left a message w/ the time and a number to call. 07/16/2001 at approx 2:15 pm Bill called me at
0008073523 2001-09-13 Production Wells No Violations Gas is leaking from 4.5 to 2 wellhead. Has a strong H2S odder at this time. Houghton Investments its Agents, Assignees and Successors shall make all necessary repairs to prevent the escape of gas from the wellhead.
0009273535 2001-09-26 Production Wells No Violations I talk to Bill Atha, he told me that he had tightened the wellhead and stopped the gas leak. At this time the well is still leaking.
0026373663 2002-06-06 Production Wells No Violations Chk well and storage, OK exept for wellhead. The wellhead is leaking again. Took photo.
0118343298 2005-10-12 Plug / Plug Back No Violations Inspect Location. All equipment has been removed except production line.
0124381178 2007-06-21 Plug / Plug Back Violations Noted Inspect well location. One inch lines and other oil field debris needs to be removed.
0172287095 2001-09-26 Production Wells Violations Noted FOLLOW UP TO NOV # 92 I talk to Bill Atha, he told me that he had tightened the wellhead and stopped the gas leak. At this time the well is still leaking.
0173507105 2007-10-18 Final Restoration No Violations inspect location. Final restoration complete. Release all previous NOVs.
0520415844 2006-12-21 Plug / Plug Back No Violations Inspect location for final restoration . Production lines have not been removed.
0624831164 2001-09-26 Production Wells Violations Noted FOLLOW UP TO NOV # 92 I talk to Bill Atha, he told me that he had tightened the wellhead and stopped the gas leak. At this time the well is still leaking.
0764040351 2001-06-20 Production Wells Violations Noted FOLLOW UP TO NOV # 27 Major gas leaks fixed, still has a small leak at the 41/2 to tubing connection. Id posted.
0807108355 2003-08-11 Production Wells No Violations Well inspection. ID is present but faded. Well is leaking gas from back side of 4.25 inch casing. Chart recorder has been removed. Well shut in. Steel well head is significantly rusted.
1109785119 2005-03-02 Production Wells No Violations Follow up of previous NOV.Casing gas not leaking, repairs made. Could hear leak before.No audible or visual leaks. Could smell H2S odor. Casing and tubing is beginning to show signs of metal decay due to H2S gas.
1134080839 2005-06-13 Plug / Plug Back No Violations Bottom plug set. Release parmaco packer pull 4.5 till locked in well at 1062 feet. Total of 367.9 feet pulled. Bull head bottom plug.
1210i18519 2001-06-15 Production Wells No Violations Well inspection result of complaint (Linda Taylor). ID posted but faded. Gas leak at fitting on separator 1/4 inch line from separator to murphy switch. Small leak of raw gas. ( H2S). Wellhead leaking from casing head strong leak of H2S gas. Gas meter at leak reads 5 on meter. Downwind 15 feet meter reading zero. Stopped at complainants home and explained what we found. Left business card, with Sam and my numbers. This date Sam called Bill Atha and requested Ids remarked and leak repaired. 3 digital photos taken. Accompanied by Inspector Faust.
1210i1851964 2001-6-15 0:00: PW No Violations
1210i26545 2001-11-28 Production Wells No Violations This well had a gas odor complaint where well head was leaking. Inspector Faust got the company to tighten the well head. Well head is still leaking. Worst gas odor ( H2S) is coming from the top of the plastic fluid tank. Gas is coming from the fluid line at the separator and entering into the plastic tank. Gas has strong H2S odor and is audible bubbling thru fluid in tank.
1210i2654544 2001-11-28 0:00 PW No Violations
1533024945 2002-10-23 Production Wells Violations Noted Well inspection. Identification is inadequate. Surface soils have collapsed around the Well head casing creating a hole three-(3) to four-(4) feet deep.
1585274658 2004-10-04 Production Wells No Violations inspect Well. Plug Application has been received. Closed old NOVs. ID faded. Pipes are rusted and valves froze.
Plug application expires 7/6/05.
172287095 2001-9-26 0:00: PW No Violations
1880210490 2005-08-01 Plug / Plug Back No Violations Inspect location. Well plugged, pit closed. Tubing, 4.5 inch pipe, and well head pipe at location. Production Equipment in place.
2043861760 2001-06-20 Production Wells Violations Noted FOLLOW UP TO NOV # 27 Major gas leaks fixed, still has a small leak at the 41/2 to tubing connection. Id posted.
26373663 2002-6-6 0:00:0 PW No Violations
2773471 2001-6-20 0:00: PW No Violations
3273475 2001-7-12 0:00: PW No Violations
520415844 2006-12-21 0:00 PB No Violations
624831164 2001-9-26 0:00: PW No Violations
8073523 2001-9-13 0:00: PW No Violations
9273535 2001-9-26 0:00: PW No Violations
iDIAN00516 2000-08-07 Preliminary Restoration No Violations
iDIAN005162 2000-8-7 0:00:0 PL No Violations
iTOMK00002 2000-04-10 Production Wells No Violations
iTOMK000028 2000-4-10 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0124381178 US-OH-106499 2007-07-05 Failure to remove production equip. within 6 mos. REPLACE
0172287095 US-OH-117087 2001-09-13 Well insufficiently equipped to prevent escape of oil and gas
0172287095 US-OH-117088 2001-09-13 Unlawful venting or flaring of gas
0172287095 US-OH-117089 2001-10-19 Well shall be plugged
0624831164 US-OH-127065 2001-09-13 Well insufficiently equipped to prevent escape of oil and gas
0624831164 US-OH-127066 2001-09-13 Unlawful venting or flaring of gas
0624831164 US-OH-127067 2001-10-19 Well shall be plugged
0764040351 US-OH-128685 2001-06-15 Failure to legibly identify well
0764040351 US-OH-128686 2001-06-15 Unlawful venting or flaring of gas
0764040351 US-OH-128687 2002-04-03 Disposal of muds or cuttings in violation of a rule
1533024945 US-OH-114738 2002-10-24 Failure to legibly identify well
2043861760 US-OH-120802 2001-06-15 Failure to legibly identify well
2043861760 US-OH-120803 2001-06-15 Unlawful venting or flaring of gas
2043861760 US-OH-120804 2002-04-03 Disposal of muds or cuttings in violation of a rule

For data sources see[8]

References