Well Details

Well ID: 37-063-36396
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: Burrell Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: R C L SHUMAKER 3
License Status:
Spud Date: 2009-07-01
Permit Date: 2009-01-07
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.463547
Longitude: -79.271936

For data sources see[1][2][3]

Well History

Date Event
2009-01-07 New Permit Application
2009-07-01 Performed Spud Operation
2009-07-08 Drilling Completion
2009-07-16 Perforation
2009-10-08 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 PHILLIPS EXPLORATION INC 7784.00 106 0.00 0 0.00 0
2010 PHILLIPS EXPLORATION INC 23,172.00 362 0.00 0 0.00 0
2011 PHILLIPS EXPLORATION INC 11,445.00 352 0.00 0 0.00 0
2012 XTO ENERGY INC 6,980.00 366 0.00 0 0.00 0
2013 XTO ENERGY INC 12,063.00 365 0.00 0 0.00 0
2014 XTO ENERGY INC 11,115.00 365 0.00 0 0.00 0
2015 XTO ENERGY INC 8,336.00 358 0.00 0 0.00 0
2016 XTO ENERGY INC 3,861.00 366 8.14 366 0.00 0
2017 ALLIANCE PETRO CO LLC 5,612.00 334 32.00 334 0.00 0
2018 ALLIANCE PETRO CO LLC 6,151.00 365 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 5,621.00 365 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 PHILLIPS EXPLORATION INC Produced Fluid 2.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2010 PHILLIPS EXPLORATION INC Produced Fluid 17.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2010 PHILLIPS EXPLORATION INC Produced Fluid 1.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 PHILLIPS EXPLORATION INC Produced Fluid 2.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026310
2010 PHILLIPS EXPLORATION INC Produced Fluid 3.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2010 PHILLIPS EXPLORATION INC Produced Fluid 1.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0020346
2010 PHILLIPS EXPLORATION INC Produced Fluid 1.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0026034
2013 XTO ENERGY INC Produced Fluid 41 Bbl CENT WASTE TRT FAC NPDES PA0095273
2013 XTO ENERGY INC Produced Fluid 41.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2014 XTO ENERGY INC Produced Fluid 16.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2014 XTO ENERGY INC Produced Fluid 16 Bbl CENT WASTE TRT FAC NPDES PA0095273
2016 XTO ENERGY INC Produced Fluid 0.11 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2016 XTO ENERGY INC Produced Fluid 0.11 Bbl CENT WASTE TRT FAC NPDES PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1804521 Primary Facility 2009-05-27 Drilling/Alteration No Violations Noted well staked - not drilled/site made - E&S ok/ID&pit ok
1808388 Primary Facility 2009-06-12 Routine/Complete Inspection No Violations Noted id sign & e/s n site, location staked, site constructed, pit dug but unlined. no rig
1822421 Primary Facility 2009-08-20 Routine/Complete Inspection No Violations Noted The well has been drilled and in production. Well site has been regraded, seeded, and mulched. There are no erosion and sedimentation issues on well site and access road. There are two pits on site one of which still contains drill cuttings. The liner is showing signs of compromise. The operator should dispose of the cuttings and liners set forth in the E&S plan asap.
1883176 Primary Facility 2010-05-10 Site Restoration No Violations Noted At the time of inspection, the well was tagged and appeared to be in production. Brine tank appeared in sound condition. Site had been regraded and seeded, but significantly less than 70% successful vegetative growth was observed; therefore, it is recommended the operator reseed and mulch the site as soon as possible in order to adhere by regulations. No accelerated erosion or sedimentation issues were observed in relation to site. It is recommended that the operator continue to maintain access road in order to prevent erosion. Detected a faint gas odor near well. An inspection will be done in the near future to ensure FINAL restoration measures have been completed according to O&G regulations.
1941719 Primary Facility 2011-01-07 Routine/Complete Inspection No Violations Noted Tag, tank, e&s ok.
2142727 Primary Facility 2013-02-22 Routine/Complete Inspection No Violations Noted At time of inspection, well in production. Located in ag field. Well tag present, legible. Brine tank sound. Access road in good condition. No accelerated E&S concerns noted. Site permanently stabilized with >70% vegetative growth achieved. Department recommends Operator continue to monitor and maintain well site and access road as needed.
2232846 Primary Facility 2013-12-31 Routine/Complete Inspection No Violations Noted Tag, tank, e&s ok.
2318322 Primary Facility 2014-11-03 Routine/Complete Inspection No Violations Noted Tag, tank, e&s ok.
2354557 Primary Facility 2015-03-24 Routine/Complete Inspection No Violations Noted At time of inspection, well drilled and appears equipped for production. According to records, drilling occurred 07/01/2009- 07/07/2009.
2528609 Primary Facility 2016-10-06 Routine/Complete Inspection No Violations Noted 10/6/2016 - Tag, tank, annulus closed.

For data sources see[7]