X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-28567

Well Details

Well ID: 37-129-28567
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Derry Township
Operator Name: XPR RESOURCES LLC
Well Pad ID: 148377
Farm/Lease Name: FRYE SOUTH 1-2H
License Status:
Spud Date:
Permit Date: 2011-03-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.375272
Longitude: -79.286622

For data sources see[1][2][3]

Well History

Date Event
2011-03-29 New Permit Application
2011-04-11 Performed Spud Operation
2011-06-09 Drilling Completion
2011-09-27 Perforation
2013-05-28 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-09-22 2011-09-22 8,101 5,742,265

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.10
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 11.53
WG-36 Gelling Agent Halliburton Energy Services Gel Guar gum 9000-30-0 100.00 0.00060000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00430000
GBW-30 Breaker Halliburton Energy Services Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00020000
Carbohydrates 95.00 0.00110000
BE-9M Halliburton Energy Services Biocide
Methanol 67-56-1 30.00 0.00580000
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00190000
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00120000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Water Carrier/Base Fluid Water 100.00 88.32

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 24,169.00 11 0.00 0 0.00 0
2012 XPR RESOURCES LLC 872,128.71 366 0.00 0 0.00 0
2013 XPR RESOURCES LLC 486,437.07 365 0.00 0 0.00 0
2014 XPR RESOURCES LLC 319,170.06 364 0.00 0 0.00 0
2015 XPR RESOURCES LLC 218,641.85 365 0.00 0 0.00 0
2016 XPR RESOURCES LLC 164,900.56 366 0.00 0 0.00 0
2017 XPR RESOURCES LLC 149,883.77 364 0.00 0 0.00 0
2018 XPR RESOURCES LLC 126,893.00 365 0.00 0 0.00 0
2019 XPR RESOURCES LLC 92,324.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 XPR RESOURCES LLC Drill Cuttings 1,854.00 Tons LANDFILL 100419
2012 XPR RESOURCES LLC Fracing Fluid Waste 330.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2012 XPR RESOURCES LLC Produced Fluid 2,275.27 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 XPR RESOURCES LLC Produced Fluid 962.39 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2013 XPR RESOURCES LLC Produced Fluid 5,212.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XPR RESOURCES LLC Produced Fluid 1,380.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 XPR RESOURCES LLC Drilling Fluid Waste 18,811.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XPR RESOURCES LLC Produced Fluid 605.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2015 XPR RESOURCES LLC Fracturing Fluid Waste 18.00 Tons LANDFILL 100434
2016 XPR RESOURCES LLC Produced Fluid 330.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2016 XPR RESOURCES LLC Produced Fluid 440.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 XPR RESOURCES LLC Produced Fluid 330.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2017 XPR RESOURCES LLC Waste comment only 0.00
2017 XPR RESOURCES LLC Produced Fluid 330.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0254185
2018 XPR RESOURCES LLC Produced Fluid 460.00 Bbl REUSE (AT WELL PAD)
2018 XPR RESOURCES LLC Produced Fluid 350.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005
2019 XPR RESOURCES LLC Produced Fluid 280.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1957271 Primary Facility 2011-03-15 Routine/Complete Inspection No Violations Noted Inspection was in response to OG-57 Waiver Request for a site within 100' of a pond and a stream. Waiver is being approved with the following comments:
1964443 Primary Facility 2011-04-01 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection.
1969098 Primary Facility 2011-04-25 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection.
1982095 Primary Facility 2011-06-09 Routine/Complete Inspection No Violations Noted Site visit was in response to reported spill on 6-7-11.
1985336 Primary Facility 2011-07-01 Routine/Complete Inspection No Violations Noted Site visit was part of routine inspection.
2140635 Primary Facility 2013-02-19 Routine/Complete Inspection No Violations Noted no violations noted
2244302 Primary Facility 2014-01-11 Routine/Complete Inspection No Violations Noted At the time of inspection the Department notes that the well appears to be drilled and equipped for production. The well apparatus, brine tank and gas production unit appear to be in sound condition. The Erosion and Sedimentation Plan was onsite and appeared to be implemented as designed. The impoundment associated with the well also appears to be in sound condition and had the required 2' of freeboard. During a phone conversation with the Operator personnel the Operator indicated intention to move the water located from the pit onsite for disposal. During the conversation the Operator indicated the water was moved from the Marco Well pad site and was not used at this site. The Department suggests the Operator contact PA DEP Waste to review the 100% rule and proceed based on that conversation to ensure the pit located onsite does not become an unintentional transfer station The Department suggests the Operator continue to monitor the site weekly and after significant precipitation event to ensure the stability of the site in maintained.
2452527 Primary Facility 2016-02-23 Routine/Complete Inspection No Violations Noted Access road gated and locked, shared with farm. At the time of inspection well appears equipped for production. Well tag present and affixed in a permanent manner. Four brine tanks located on site within secondary containment and appear to be structurally sound. Site permanently stabilized, no E& S issues in relation to site and/or access road.
2474524 Primary Facility 2016-04-13 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production equipment-tank battery and dike look ok.
2554689 Primary Facility 2017-01-24 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2621644 Primary Facility 2017-08-02 Routine/Complete Inspection No Violations Noted Well tagged-on. Well head casing-production set equipment-tank battery-dike containment look ok.
2690473 Primary Facility 2018-02-01 Routine/Complete Inspection Violation(s) Noted At the time of inspection well equipped for production. Four brine tanks within secondary containment and appear to be structurally sound. No E&S issues.

Site id sign updated to reflect current Operator information. PPC plan and ERP appears to reflect outdated Operator information. Department request Operator update documents accordingly in accordance with regulation. Violations are being issued under 25 PA Code 78a.55(i)(5)(i) and 25 PA Code 78a.55(i)(5)(iii).

2738249 Primary Facility 2018-03-02 Compliance Evaluation No Violations Noted ERP and PPC plan updated.

Previously issued violations have been corrected.

2773065 Primary Facility 2018-09-11 Routine/Complete Inspection No Violations Noted At the time of inspection well equipped for production. Brine tanks within secondary containment and appears structurally sound. No E and S issues.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2690473 807608 2018-02-01 2018-03-02 78a55(i)5i Environmental Health & Safety
2690473 807609 2018-02-01 2018-03-02 78a55(i)5iii Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
807608 361323 NOV - Notice of Violation 2019-01-23
807608 371697 CACP - Consent Assessment of Civil Penalty COMP - Completed 2019-01-23 2019-01-23 $11,000.00 $11,000.00
807609 361323 NOV - Notice of Violation 2019-01-23
807609 371697 CACP - Consent Assessment of Civil Penalty COMP - Completed 2019-01-23 2019-01-23 $11,000.00 $11,000.00

For data sources see[8]

References