If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-005-20134 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.75,"lon":-82.15,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Mohican Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: HOOTMAN & CRUMLICK | |
License Status: Producing | |
License Date: | |
Spud Date: 1941-03-21 | |
Spud Drilling Contractor: | |
Final Drill Date: 1941-08-22 | |
Well Total Depth: 2881.00 ft | |
Configuration: Vertical | |
Latitude: 40.750000 | |
Longitude: -82.150000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1941-03-21 | QUAD=WEST SALEM:GL=1019.2 PROD. FORM=GRIT |
Completed | 1941-08-22 | QUAD=WEST SALEM:GL=1019.2 PROD. FORM=GRIT |
Reached Total Depth | 1941-08-22 | QUAD=WEST SALEM:GL=1019.2 PROD. FORM=GRIT |
CO | 1991-02-22 | 2936 COLUMBIA NATURAL RES INC |
Change of Owner | 2005-02-04 | Operator changed from 2936, COLUMBIA NATURAL RES INC to 7774, AMERICAN OIL & GAS LLC |
Change of Owner | 2007-01-25 | Operator changed from 7774, AMERICAN OIL & GAS LLC to 8154, AB RESOURCES OH LLC |
Change of Owner | 2010-09-21 | Operator changed from 8154, AB RESOURCES OH LLC to 8685, M & R INVESTMENTS OHIO LLC |
Change of Owner | 2015-10-14 | Operator changed from 8685, M & R INVESTMENTS OHIO LLC to 7859, MALLETT LUKE-DBA MALLET ENERGY |
Change of Owner | 2017-05-03 | Operator changed from 7859, MALLETT LUKE-DBA MALLET ENERGY to 9651, AM-TEK OIL INC |
Record Last Modified | 2017-05-03 | QUAD=WEST SALEM:GL=1019.2 PROD. FORM=GRIT |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 2850 | 2858 | 0 |
2006-09-11 | 2870 | 2875 | 0 |
2850 | 2858 | 0 | |
2850 | 2858 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
Not Treated | 0 | 50 Qts | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-161818983 | 2014-8-21 0:00: | PW | No Violations | |
-1731448352 | 2018-3-20 0:00: | PW | No Violations | |
-1768274200 | 2017-3-13 0:00: | PW | No Violations | 0.50 |
-2083105373 | 2014-7-17 0:00: | PW | No Violations | 0.50 |
-819526740 | 2015-12-22 0:00 | PW | No Violations | 0.50 |
0161818983 | 2014-08-21 | Production Wells | No Violations | Inspect well. Measure pressure on annulus at 10 psi. Measure pressure on 3 inch tubing at 10 psi, gate valve may be closed. |
0452676342 | 2017-01-12 | Production Wells | Violations Noted | Harley Drilling requested an inspection of the well because their well tender observed water bubbling up 8 to 12 inches out of the ground in the vicinity of the well. Upon arrival, there was an area in the field between the well and County Road 175 along the path of the Aspire Energy pipeline where water was bubbling up. Gas odor was observed. Aspire Energy was contacted and responded out to the leak. They confirmed the leak was from their line and will repair it. The Divisions Duty Officer was notified. No leakage was observed at the well. The well is unidentified. Post identification at the well by 3/13/17. |
0819526740 | 2015-12-22 | Production Wells | No Violations | The well is still not identified. M&R Investments transferred the well to Luke Mallet in October 2015. Mallet was contacted at 740-826-2122 and a message was left for him to contact the inspector regarding this well. The well is shut in. Aspire Energy has utility marking flags in the area. The resident at the farm stated that they repaired leaks in the pipeline. |
1515778851 | 2018-01-11 | Production Wells | No Violations | Amtek Oil was contacted regarding the well. Theyve recently taken ownership of this well and others from Mallet Energy. They have not updated the ID signs at the wells yet. Andrew Ulrich of Amtek stated he would come over and post identification on the well. |
1557341994 | 2014-08-07 | Production Wells | No Violations | The operator has corrected the gas leak from the well. The surface casing was patched and a one half inch fitting was installed. The valve on the fitting is closed. The operator needs to run a corrosion survey on the well to determine the status of the production casing. The NOV from 7/17/14 is terminated. |
1686145872 | 2014-07-22 | Production Wells | No Violations | The operator cleared brush around the well. They attempted to repair the leak with a temporary rubber patch, however it is not sealed. The casing is rusted out and leaking gas. The well will need to be plugged if the casing cannot be repaired. The pumper was contacted via phone and advised that the well is still leaking. He is going to attempt to repair the 1 inch fitting on the 8 inch casing to thread a plug into it, however he was advised that the production casing needs to be inspected to determine its integrity. The amount of gas venting from the well indicates that the production casing has failed. |
1731448352 | 2018-03-20 | Production Wells | No Violations | Inspection was conducted with Andrew of Amtek Oil. The operator posted identification at the well. The operator is going to service the well and return it to production. |
1768274200 | 2017-03-13 | Production Wells | No Violations | The well remains shut in. Mallet Energy has not posted identification at the well yet. The well is unidentified. Mallet has not returned phone calls regarding this well. The compliance date is extended until 5/12/17. A voice message was left at Mallet Energy today. |
2083105373 | 2014-07-17 | Production Wells | Violations Noted | The well is leaking gas from the production casing at the ground surface. The operator has failed to clear trees and brush around the well. The well tender was contacted and is on the way to the location. A violation is being issued for failure to contain formation pressure. Repair the well by August 17, 2014. |
452676342 | 2017-1-12 0:00: | PW | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0452676342 | US-OH-124902 | 2018-06-08 | 9-9-05(A)10 | Failure to legibly identify well |
2083105373 | US-OH-121255 | 2015-12-10 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]