If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-005-21272 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.62,"lon":-82.27,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Hanover Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: WELSH P HERBERT | |
License Status: Storage Well | |
License Date: | |
Spud Date: 1971-10-30 | |
Spud Drilling Contractor: | |
Final Drill Date: 1971-11-24 | |
Well Total Depth: 2938.00 ft | |
Configuration: Vertical | |
Latitude: 40.620000 | |
Longitude: -82.270000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1971-10-30 | |
Completed | 1971-11-24 | |
Reached Total Depth | 1971-11-24 | |
Record Last Modified | 2013-05-23 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1471068825 | 2015-11-16 0:00 | SO | No Violations | 0.50 |
-391779284 | 2016-11-3 0:00: | SO | No Violations | 0.50 |
-508147690 | 2014-11-4 0:00: | SO | No Violations | 0.50 |
-526496476 | 2018-11-19 0:00 | SO | No Violations | |
-747335232 | 2020-3-12 0:00: | SO | No Violations | |
0391779284 | 2016-11-03 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator. |
0508147690 | 2014-11-04 | Storage Well | No Violations | ID posted, location maintained. |
0526496476 | 2018-11-19 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator and house gas connection at the pipeline tie in. |
0534298367 | 2019-06-06 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #11094 on 06/06/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-meter with 2-regulators. Well identification is clearly displayed. No problems were noted at the time of the inspection. |
1266005104 | 2014-02-13 | Storage Well | No Violations | ID posted. There is an abandoned tank battery location at the well site. There is a 2 inch flow line inside the dyke and a ladder. The tanks have been removed. The dyke area needs to be reclaimed. |
1394811389 | 2017-08-11 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator and house gas tap at the pipeline tie in. |
1471068825 | 2015-11-16 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. |
2054856884 | 2019-03-04 | Storage Well | No Violations | Inspect well, identification is posted. A drip is located in line. Gas meter is located at well head. |
534298367 | 2019-6-6 0:00:0 | SO | No Violations |
For data sources see[3]