If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-005-22220 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.89,"lon":-82.15,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Perry Township | |
Operator Name: DEEP RESOURCES LLC | |
Well Pad ID: | |
Farm/Lease Name: GORTNER R & P | |
License Status: Active Injection | |
License Date: 1976-02-18 | |
Spud Date: 1976-02-17 | |
Spud Drilling Contractor: SHORTS DRLG | |
Final Drill Date: 1976-09-14 | |
Well Total Depth: 701.00 ft | |
Configuration: Vertical | |
Latitude: 40.890000 | |
Longitude: -82.150000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1976-02-17 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
CO | 1976-02-18 | 133 QUAKER STATE OIL REF CORP GeoDate 2/18/76 |
Enhanced Recovery | 1976-02-18 | Issued Date 2/18/76 Expired Date 2/17/77 Acres 0203000 Tool Type CT Proposed Formation BEDFORD Proposed Depth 00000 Proposed Drill Depth 00000 |
Completed | 1976-09-14 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
Reached Total Depth | 1976-09-14 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
Construction Permit Expires | 1977-02-17 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
CO | 1995-10-18 | 182 BELDEN & BLAKE CO GeoDate 2/18/76 |
Annulus Pressure Monitoring Approved | 1996-07-09 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
Last Compliance Report | 2001-01-10 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
Change of Owner | 2007-04-27 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC |
Change of Owner | 2012-11-16 | Operator changed from 7578, ENERVEST OPERATING L to 8227, DEEP RESOURCES LLC |
Record Last Modified | 2017-02-15 | CON. SEC. RECOVERY 3-26-75, RE-ISSUE 2-11-76 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-22 | 554 | 683 | 0 |
2006-09-11 | 556 | 683 | 0 |
560 | 680 | 0 | |
554 | 683 | 0 | |
556 | 683 | 0 | |
554 | 683 | 0 | |
2000-05-22 | 560 | 680 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
Not Treated | 0 | 254 Qts | 0 | WHT. WTR. TAMP. | ||
NITR | 0 | 254 Qts | 0 | FOR ERP | ||
NITR | 0 | 170 Qts | 0 | FOR PRODUCTION |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | DEEP RESOURCES LLC | 0.00 | 133.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | DEEP RESOURCES LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-107637317 | 2013-8-29 0:00: | ER | No Violations | |
-1347910893 | 2018-4-23 0:00: | ER | No Violations | |
-145568931 | 2005-4-28 0:00: | ER | No Violations | 0.50 |
-1610189177 | 2011-10-17 0:00 | ER | No Violations | |
-1734125552 | 2019-10-23 0:00 | ER | No Violations | |
-1803882646 | 2013-10-29 0:00 | ER | No Violations | |
-1862266217 | 2015-9-23 0:00: | ER | No Violations | |
-1926307451 | 2020-7-15 0:00: | ER | No Violations | |
-1941687240 | 2007-10-12 0:00 | ER | No Violations | 0.50 |
-1998991993 | 2011-7-12 0:00: | ER | No Violations | |
-2076147986 | 2016-5-25 0:00: | WR | No Violations | |
-2113076327 | 2006-12-14 0:00 | ER | No Violations | 1.00 |
-250714346 | 2014-7-17 0:00: | ER | No Violations | |
-354348811 | 2017-7-18 0:00: | ER | No Violations | |
-374395248 | 2019-1-14 0:00: | ER | No Violations | |
-412310811 | 2019-4-10 0:00: | ER | No Violations | |
-544067272 | 2008-12-3 0:00: | ER | No Violations | 0.50 |
-635513834 | 2010-11-26 0:00 | ER | No Violations | 0.50 |
0009989503 | 2013-03-04 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0028074834 | 2015-05-13 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. Well is shut in. |
0050757403 | 2012-11-27 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. Injection line Tee leaking. |
0096408762 | 2016-01-06 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. Well was shut in upon inspection. Notified operator and injection valve was partially opened and put into production. |
0107637317 | 2013-08-29 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0113455110 | 2009-10-07 | Enhanced Recovery Project | Violations Noted | Injection and annulus pressure test. |
0145568931 | 2005-04-28 | Enhanced Recovery Project | No Violations | Injection pressure test. |
0250714346 | 2014-07-17 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0354348811 | 2017-07-18 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0449457198 | 2012-05-31 | Enhanced Recovery Project | No Violations | Inspect Well. No Valve on Injector. Owner Name needs to be updated. |
0468783087 | 2007-03-30 | Enhanced Recovery Project | No Violations | Annulus and injection pressure test. |
0544067272 | 2008-12-03 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0635513834 | 2010-11-26 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0700159640 | 2013-05-22 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0782353772 | 2003-11-13 | Enhanced Recovery Project | No Violations | |
0859169276 | 2009-04-23 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0912960573 | 2016-01-07 | Enhanced Recovery Project | Violations Noted | Inspect well for integrity and pressure. The operator partially opened the injection valve to put well into production. Retest well to check pressure and integrity. During inspection the annulus had pressure where as there was zero pressure the previous days inspection. The packer appears to have failed. |
0919503521 | 2014-05-27 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0998884457 | 2010-04-05 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1082806128 | 2017-01-06 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
113455110 | 2009-10-7 0:00: | ER | No Violations | 0.50 |
1138293716 | 2006-01-26 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1174846146 | 2012-09-20 | Enhanced Recovery Project | No Violations | Inspect Well. Injector Valve port stripped. |
1210491559 | 2014-03-17 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. The valve for the annulus is frozen. Solvent tank is attached to the injection line, preventing collection of injection pressure. |
1245000242 | 2016-04-19 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. Compliance notice issued on January 8, 2015. The well has not been serviced. |
1263717694 | 2020-5-13 0:00: | ER | No Violations | |
1344130434 | 2019-7-23 0:00: | ER | No Violations | |
1344382967 | 2014-03-17 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. The valve for the annulus was frozen during previous days inspection. Re-test annulus on well. |
1347910893 | 2018-04-23 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1355889257 | 2018-07-06 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1389652762 | 2016-07-06 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. The well head fittings have recently been replaced. |
1415333600 | 2016-10-19 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1464092755 | 2016-05-23 | Work Over Reconditioning | No Violations | The operator has moved the small service rig off the well and moved the large service rig onto the well. No activity is occurring on the well during the inspection. The operator reported that the packer is stuck in the hole and will not move up hole. The operator parted the one inch tubing two joins in the hole. The reaming tubing and packer have fallen to the bottom of the hole. |
1465398209 | 2016-05-26 | Work Over Reconditioning | No Violations | The well is constructed with 2-3/8 inch tubing at a depth of 550 feet cemented to the surface. The well is open hole from 550 feet to the total depth of 701 feet. The Berea Formation is from 556 feet to 683 feet. On May 16, 2001 the packer was set in tension reported at a depth of 525 feet with 21 joints. Compliance Notice was issued on January 8, 2016 indicating that the mechanical integrity of the well failed. Upon servicing the well the operator had difficulty removing the packer and tubing. The tubing parted at 50 feet below grade and the packer and tubing fell to the bottom of the hole. The tubing was speared and fished out of the hole. The old Butler-Larkin packer parted from the tubing and was lost in the hole and remains at the bottom of the well. A total of 22 joints at 25 feet long and one pup joint at 1.5 feet were recovered from the well. The existing Seal-tite lined tubing was reused, except five joints of tubing were in poor condition or damaged at the surface and were replaced. A new remanufactured Parmaco style unlined chrome plated packer was run in the hole in compression with 21 joints of Seal-tite lined tubing. Approximately 300 gallon of fresh water with inhibitor were pumped through the annulus and circulated out the tubing to the surface. The mechanical integrity pressure test failed at the initial depths where the packer was set. Subsequently the packer was moved up hole for retesting. The packer was set at the following depth and did not pass, 525 feet, 524 feet, and 520, feet. The operator moved the packer up hole and removed one joint of tubing. The packer was set with a total of 20 joints of tubing at a depth of 500 feet. The annulus was pressured up to 440 psi. The pressure was monitored for 15 minutes with less than 1 percent pressure loss. This is within the stated margin of 5 percent pressure loss. The well passes the Mechanical Integrity Test. The well head was reconstructed with new parts and put into production. |
1509113918 | 2017-10-19 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1515777461 | 2018-01-04 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1599272904 | 2008-02-20 | Enhanced Recovery Project | Violations Noted | Annulus and injection pressure test. Injection valve in box is leaking fluid. Repair valve ASAP. |
1610189177 | 2011-10-17 | Enhanced Recovery Project | No Violations | Inspect well. Well ownership needs review. |
1617494427 | 2009-10-20 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1638065043 | 2017-04-13 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1655829721 | 2006-04-25 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1772675157 | 2011-04-13 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1803882646 | 2013-10-29 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1834944063 | 2008-03-13 | Enhanced Recovery Project | No Violations | Leak has been repaired on injection line. NOV in compliance. |
1862195223 | 2012-03-07 | Enhanced Recovery Project | No Violations | Inspect Well. Pressure on injector line due to solvent system. No reading for injector. |
1862266217 | 2015-09-23 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. The injector has zero pressure and may be plugged. The Annulus test valve needs to be replaced, threads leak on gauge. |
1876438888 | 2015-09-28 | Administrative Inspection | No Violations | Operator inspected well head and determined the injection line is plugged. The well head will require replacement of all well head parts after further evaluation. |
1881358711 | 2014-10-28 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
1883099978 | 2015-10-06 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. Operator reported there was a tubing line plug that was cleaned out and well head fitting were repaired and replaced. |
1940579143 | 2004-04-22 | Enhanced Recovery Project | No Violations | Injection pressure test. Annular pressure needs re-tested and reported to Tom Tomastik in 30 days. Advised Len Rex to repressure annular space. |
1941687240 | 2007-10-12 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1966039779 | 2020-1-17 0:00: | ER | No Violations | |
1998991993 | 2011-07-12 | Enhanced Recovery Project | No Violations | inspect well. Conduct mini test, ok. |
2050497528 | 2004-11-18 | Enhanced Recovery Project | No Violations | Injection pressure test. |
2076147986 | 2016-05-25 | Work Over Reconditioning | No Violations | Operator reported that 22 joints of one inch Seal-tite lined tubing and one 18 inch long pup joint of tubing were recover from the well. The packer was lost in the hole. |
2113076327 | 2006-12-14 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. Surface valves and 1 tubing rusted and scaled. It is not leaking. |
2126643091 | 2018-10-12 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
28074834 | 2015-5-13 0:00: | ER | No Violations | |
449457198 | 2012-5-31 0:00: | ER | No Violations | |
468783087 | 2007-3-30 0:00: | ER | No Violations | |
50757403 | 2012-11-27 0:00 | ER | No Violations | |
700159640 | 2013-5-22 0:00: | ER | No Violations | |
782353772 | 2003-11-13 0:00 | ER | No Violations | |
859169276 | 2009-4-23 0:00: | ER | No Violations | 0.50 |
912960573 | 2016-1-7 0:00:0 | ER | No Violations | |
919503521 | 2014-5-27 0:00: | ER | No Violations | |
96408762 | 2016-1-6 0:00:0 | ER | No Violations | |
998884457 | 2010-4-5 0:00:0 | ER | No Violations | 0.50 |
9989503 | 2013-3-4 0:00:0 | ER | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0113455110 | US-OH-103410 | 2009-10-07 | Failure to conduct or pass mech. integrity test | |
0912960573 | US-OH-130422 | 2016-06-15 | Mechanical failure/contamination | |
1599272904 | US-OH-115669 | 2008-02-20 | Pollution/Contamination |
For data sources see[9]