X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-22568

Well Details

Well ID: 34-005-22568
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: E. SMALLEY
License Status: Final Restoration
License Date: 2010-06-18
Spud Date: 1983-08-05
Spud Drilling Contractor: HILLER DRLG
Final Drill Date: 1983-09-16
Well Total Depth: 680.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -82.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1967-02-07 Issued Date 2/7/67 Expired Date Acres 0080000 Tool Type RTAF Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1967-02-09 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
CO 1983-06-07 133 QUAKER STATE OIL REF CORP GeoDate 6/7/83
Enhanced Recovery 1983-06-07 Issued Date 6/7/83 Expired Date 12/4/83 Acres 0080000 Tool Type CT Proposed Formation BEREA Proposed Depth 00680 Proposed Drill Depth 00680
Completed 1983-09-16 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Reached Total Depth 1983-09-16 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
CO 1983-10-07 133 QUAKER STATE OIL REF CORP GeoDate 2/7/67
First Injection 1983-10-07 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Completion Report Received 1983-10-19 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 6/7/83
Annulus Pressure Monitoring Approved 1996-08-02 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Last Compliance Report 1999-12-15 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Plugged/Abandoned 2010-06-10 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
APP 2010-06-18 Proposed Formations:BEREA, Issued Date:6/18/2010, Expired Date:6/18/2011 6:00:00 AM, Drilling unit acres:60, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2011-06-18 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Record Last Modified 2017-02-15 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-23 608 619 0
608 619 0
608 619 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 11 Qts 0 ORIGINALLY SHOT WITH 25 QTS OF NITROGLYCERINE

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1008861794 2007-10-26 0:00 ER No Violations 1.00
-1036324868 2008-2-20 0:00: ER No Violations 0.50
-1341671367 2010-10-7 0:00: FR No Violations 1.00
-1892378612 2008-12-2 0:00: ER No Violations 0.50
-389479723 2010-3-30 0:00: ER No Violations 0.50
-517752874 2008-12-10 0:00 ER No Violations 0.50
-685445944 2005-11-29 0:00 ER No Violations 0.50
-999548754 2005-4-27 0:00: ER No Violations 0.50
0035988678 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
0389479723 2010-03-30 Enhanced Recovery Project No Violations Injection and annulus pressure test. Pressures are equal at 350 psi.
0427007484 2009-10-20 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0517752874 2008-12-10 Enhanced Recovery Project No Violations Mini test on annulus. Pumped to 390 psi and psi fell to 380 psi in 15 minutes. NOV in compliance.
0590905254 2006-12-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0685445944 2005-11-29 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0765691662 2006-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0999548754 2005-04-27 Enhanced Recovery Project No Violations Injection well test.
1008861794 2007-10-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1033560801 2003-08-14 Enhanced Recovery Project No Violations PRESSURE EQUALIZATION OF TUBING AND ANNULUS, REQUESTED MINI-TEST BE PERFORMED
1036324868 2008-02-20 Enhanced Recovery Project Violations Noted Annulus and injection pressure test. Annulus pressure is 0 psi. Pressure up to 200 psi and test for 15 minutes.
1083066716 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
1175608116 2007-04-03 Enhanced Recovery Project No Violations Injection and annulaus pressure test.
1276518456 2010-06-11 Enhanced Recovery Project No Violations Unable to retrieve packer. Plugged well with cement from 475 to surface.
1341671367 2010-10-07 Final Restoration No Violations Final restoration approved. Crop Field. P&A 6-10-10.
1440653065 2010-04-02 Enhanced Recovery Project Violations Noted Injection and annulus pressure test equal at 360 psi. Reset packer and test.
1892378612 2008-12-02 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Reset packer and test.
2056774433 2009-04-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2115984645 2008-02-21 Enhanced Recovery Project No Violations Retest packer. Pressured up to 220 psi and after 15 minutes 0 psi decline. NOV in compliance.
35988678 2004-11-18 0:00 ER No Violations
427007484 2009-10-20 0:00 ER No Violations 0.50
590905254 2006-12-13 0:00 ER No Violations 0.50
765691662 2006-4-13 0:00: ER No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1036324868 US-OH-100525 2008-02-20 Failure to conduct or pass mech. integrity test
1440653065 US-OH-112827 2010-04-02 Failure to conduct or pass mech. integrity test
1892378612 US-OH-119001 2008-11-26 Failure to conduct or pass mech. integrity test

For data sources see[5]