X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-23071

Well Details

Well ID: 34-005-23071
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: GORTNER ROBERT & PAULINE (ERP #12)
License Status: Active Injection
License Date: 1976-01-09
Spud Date: 1976-02-16
Spud Drilling Contractor:
Final Drill Date: 1976-03-09
Well Total Depth: 717.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1976-01-09 133 QUAKER STATE OIL REF CORP GeoDate 1/9/76
Enhanced Recovery 1976-01-09 Issued Date 1/9/76 Expired Date Acres 0000000 Tool Type RTAF Proposed Formation BEDFORD Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1976-02-16 DRILLED BY KLAEGER DRLG RE-IS 1-14-76, RE-ISS 2-5-75
Completed 1976-03-09 DRILLED BY KLAEGER DRLG RE-IS 1-14-76, RE-ISS 2-5-75
Reached Total Depth 1976-03-09 DRILLED BY KLAEGER DRLG RE-IS 1-14-76, RE-ISS 2-5-75
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 1/9/76
Annulus Pressure Monitoring Approved 1997-09-29 DRILLED BY KLAEGER DRLG RE-IS 1-14-76, RE-ISS 2-5-75
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Last Compliance Report 2006-03-20 DRILLED BY KLAEGER DRLG RE-IS 1-14-76, RE-ISS 2-5-75
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-02-15 DRILLED BY KLAEGER DRLG RE-IS 1-14-76, RE-ISS 2-5-75

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-22 550 642 0
550 642 0
550 642 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 184 Qts 0
NITR 0 196 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC 0.00 133.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1036668367 2010-3-30 0:00: ER No Violations 0.50
-1238812044 2012-11-27 0:00 ER No Violations
-1257166226 2005-4-28 0:00: ER No Violations 0.50
-1417968671 2003-11-13 0:00 ER No Violations
-1457755269 2013-3-4 0:00:0 ER No Violations
-1473430227 2007-10-16 0:00 ER No Violations 0.50
-1626564476 2006-12-14 0:00 ER No Violations 0.50
-1697449668 2013-12-4 0:00: ER No Violations
-1735719976 2012-2-27 0:00: ER No Violations
-1790472351 2008-2-21 0:00: ER No Violations 0.50
-184974557 2014-3-17 0:00: ER No Violations
-1959465564 2009-10-7 0:00: ER No Violations 0.50
-2019020936 2015-5-15 0:00: ER No Violations 0.50
-2061889539 2009-4-27 0:00: ER No Violations 1.00
-211091945 2011-11-17 0:00 ER No Violations
-2190713 2020-7-14 0:00: ER No Violations
-226268851 2005-6-23 0:00: ER No Violations 0.50
-259332990 2014-7-17 0:00: ER No Violations
-393494607 2018-1-3 0:00:0 ER No Violations
-523890337 2011-7-12 0:00: ER No Violations
-524613322 2010-11-26 0:00 ER No Violations 0.50
-613348920 2009-4-23 0:00: ER No Violations 0.50
-615869768 2014-10-28 0:00 ER No Violations
-693889677 2020-4-22 0:00: ER No Violations
-79298187 2019-10-23 0:00 ER No Violations
-832111490 2015-5-20 0:00: ER No Violations
-908599705 2017-10-19 0:00 ER No Violations
-956788270 2018-2-28 0:00: ER No Violations
-985952499 2015-10-6 0:00: ER No Violations
0004315548 2018-05-01 Enhanced Recovery Project No Violations Inspect well with operator to preform monthly pressure test of the annulus on the well.
0010822405 2016-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0184974557 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The valve for the annulus is broken.
0211091945 2011-11-17 Enhanced Recovery Project No Violations Inspect well.
0226268851 2005-06-23 Enhanced Recovery Project Violations Noted Re- tested tubing and annulus pressure and it remains equalized. Advised Matt Miller to re-set 1 tubing packer and re- test. 90 degrees, hot.
0259332990 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well head has a slight leak, tubing is mottled.
0393494607 2018-01-03 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The flexible supply line was frozen at time of this inspection. The tubing has no pressure.
0419480062 2015-03-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The injector pressure test valve has failed and is inoperable.
0511717598 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test. Equal pressure re-test in 30 days and report.
0523890337 2011-07-12 Enhanced Recovery Project No Violations inspect well.
0524613322 2010-11-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0613348920 2009-04-23 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures ar equalized at 350 psi.
0615869768 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0772895564 2006-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test. Constructed with 2 tubing cemented at Berea cap with 1 tubing on a packer used for injection.
0797852326 2017-07-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0832111490 2015-05-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0881141437 2014-05-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0906467351 2016-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head fittings have been replaced. The operator was notified the valves were shut in. The operator subsequently opened the valves and put the well into production.
0908599705 2017-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0956788270 2018-02-28 Enhanced Recovery Project No Violations Re-Inspect well for integrity. Well head fittings were frozen during previous inspection.
0985952499 2015-10-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The fittings on the well head have been replaced. Well is in compliance.
1036668367 2010-03-30 Enhanced Recovery Project No Violations Injection and annulus pressure test.
10822405 2016-10-19 0:00 ER No Violations
1091662865 2016-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1098219106 2018-04-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1125389403 2012-05-30 Enhanced Recovery Project No Violations Inspect Well.
1133165519 2016-04-19 Enhanced Recovery Project Violations Noted Inspect well for integrity and pressure. The annulus has equalized with the injection tubing. The annulus test port shut off valve has failed. Compliance notice issued.
1138277667 2006-01-25 Enhanced Recovery Project Violations Noted Reset packer and tested annulus. Pressures are ann. 330 and inj. 350 psi. Snow, 30 degrees.
1142437933 2006-03-15 Enhanced Recovery Project No Violations Pulled 1 tubing and packer and replace packer with Larkin set down packer. Circulated 150 gallons of inhibitor and test annular pressure. See construction report. Sun, 35 degrees.
1238812044 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1257166226 2005-04-28 Enhanced Recovery Project Violations Noted Injection pressure and annular pressure is equalized. Re-pressure annular space and re-test by 5-28-2005. Report to Division the results.
1273358794 2018-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1302699223 2011-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1417968671 2003-11-13 Enhanced Recovery Project No Violations
1457755269 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1473430227 2007-10-16 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1484138394 2015-09-23 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well head tubing is rusted. Seeping at the Tee. Operator was notified of the issues and subsequently repaired. Location was re-inspected on 10/6/2015 and all parts were replaced and well was in compliance.
1485053988 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1495124492 2017-04-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1626564476 2006-12-14 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1630819538 2007-03-30 Enhanced Recovery Project No Violations Annulus and injection pressure test.
1682847775 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1697449668 2013-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Pump shut down during inspection.
1706772632 2016-05-23 Work Over Reconditioning No Violations The operator serviced the well. The well is constructed with 2 3/8 inch tubing at a depth of 546 feet cemented to the surface. The well is open hole to the total depth of 717 feet. The packer failed and was replaced. There were 19 joints of one inch lined tubing removed from the well. one joint was two feet short. The packer would have been set at 472 feet. This depth is not consistent with the last known MIT report of 3/15/2006. The top most joint of PVC lined tubing was replaced with new pipe. Total of 19 joints of 25 foot sections of PVC lined one Inch tubing was run in the hole with a parmaco style packer set in compression. The Packer was constructed with a steel tube body and was chrome plated prior to installation. The plating was an attempt to reduce failure due to rust action. Approximately 300 gallon of fresh water with inhibitor were pumped through the annulus and circulated out the tubing to the surface prior to setting the packer. The packer was set at a depth of 475 feet and the annulus was pressured up to 425 psi. This test failed. The packer was reset two feet higher at 473 feet and the annulus was pressured up to 471 psi. This test failed. The packer was released and reset at 471 feet. The annulus was pressured up to 460 psi. The pressure was monitored for 15 minutes with 2.1% pressure loss. This is within the stated margin of 5% pressure loss. The well passes the Mechanical Integrity Test. The well head was reconstructed with new parts and put into production.
1735719976 2012-02-27 Enhanced Recovery Project No Violations inspect well.
1778589525 2017-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1790472351 2008-02-21 Enhanced Recovery Project No Violations Annulus and injection pressure test.
1854119271 2018-10-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1892271728 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
1938265341 2008-12-03 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1958542452 2019-7-10 0:00: ER No Violations
1959465564 2009-10-07 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2019020936 2015-05-15 Enhanced Recovery Project No Violations The well is an injection well in the waterflood enhanced recovery project. The well is in use. ID is posted.
2061889539 2009-04-27 Enhanced Recovery Project No Violations Released 1 packer and pulled up 15. Set packer and tested. Pressure held at 300 psi for 15 minutes and 0 PSI decline. NOV in compliance.
419480062 2015-3-31 0:00: ER No Violations
4315548 2018-5-1 0:00:0 ER No Violations
480979391 2019-1-10 0:00: ER No Violations
492201182 2020-1-23 0:00: ER No Violations
511717598 2004-11-18 0:00 ER No Violations
772895564 2006-4-13 0:00: ER No Violations 0.50
797852326 2017-7-19 0:00: ER No Violations
878208726 2019-4-10 0:00: ER No Violations
881141437 2014-5-27 0:00: ER No Violations
906467351 2016-7-6 0:00:0 ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0226268851 US-OH-122254 2005-06-27 Mechanical failure/contamination
0613348920 US-OH-126936 2009-04-23 Failure to conduct or pass mech. integrity test
1133165519 US-OH-103383 2016-05-25 Mechanical failure/contamination
1138277667 US-OH-103504 2005-05-02 Mechanical failure/contamination
1257166226 US-OH-106935 2005-05-02 Mechanical failure/contamination

For data sources see[9]