X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-23747

Well Details

Well ID: 34-005-23747
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: BRETTIN
License Status: Active Injection
License Date: 1984-08-14
Spud Date: 1984-10-03
Spud Drilling Contractor: WALTZ BROS DRLG
Final Drill Date: 1984-10-04
Well Total Depth: 847.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -82.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-08-14 133 QUAKER STATE OIL REF CORP GeoDate 8/14/84
Enhanced Recovery 1984-08-14 Issued Date 8/14/84 Expired Date 2/10/85 Acres 0080000 Tool Type RTA Proposed Formation BEREA Proposed Depth 00847 Proposed Drill Depth 00847
Original Spud 1984-10-03
Completed 1984-10-04
Reached Total Depth 1984-10-04
First Injection 1984-12-29
Completion Report Received 1985-01-15
Construction Permit Expires 1985-02-10
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 8/14/84
Annulus Pressure Monitoring Approved 1998-12-03
Last Compliance Report 1999-12-22
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-23 716 790 0
2000-05-23 725 780 0
725 780 0
716 790 0
716 790 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 148 Qts 0 FOR ERP
NITR 0 148 Qts 0 LOGS ATTACHED; FOR PRODUCTION

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1051933561 2012-2-28 0:00: ER No Violations
-1077263243 2003-8-14 0:00: ER No Violations
-1336062558 2018-1-4 0:00:0 ER No Violations
-155107234 2012-2-27 0:00: ER No Violations
-1599747668 2014-3-18 0:00: ER No Violations
-1600035612 2020-1-23 0:00: ER No Violations
-1676242551 2009-9-23 0:00: ER No Violations 1.00
-1863166172 2018-8-13 0:00: ER No Violations
-1928261572 2014-10-28 0:00 ER No Violations
-1937143116 2010-4-2 0:00:0 ER No Violations 0.50
-19468828 2004-11-18 0:00 ER No Violations
-198342144 2014-7-17 0:00: ER No Violations
-2028624400 2005-11-29 0:00 ER No Violations 0.50
-2048300739 2019-1-4 0:00:0 ER No Violations
-2051556730 2019-7-2 0:00:0 ER No Violations
-2124571792 2017-7-18 0:00: ER No Violations
-2138131597 2016-4-19 0:00: ER No Violations
-241863772 2013-3-5 0:00:0 ER No Violations
-296403605 2013-4-4 0:00:0 ER No Violations
-317992423 2016-7-11 0:00: ER No Violations
-38521408 2015-8-28 0:00: ER No Violations
-717260117 2011-10-17 0:00 ER No Violations
-8383675 2018-4-23 0:00: ER No Violations
-929137830 2017-10-26 0:00 ER No Violations
-930009879 2005-12-22 0:00 ER No Violations 0.50
-961374603 2012-11-27 0:00 ER No Violations
0008383675 2018-04-23 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0012731387 2015-05-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0019468828 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
0038521408 2015-08-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0087984580 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
0115180804 2018-10-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0155107234 2012-02-27 Enhanced Recovery Project No Violations Inspect Well. Tubing plulled and on rack.
0157131961 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test. Annular and injection pressure equalized. Advised Len Rex to repressure annulus and re-test in 30 days. Report to Tom Tomastik.
0198342144 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0213176561 2012-02-06 Enhanced Recovery Project No Violations Inspect Well. Broke in. shut in well.
0220121235 2011-07-12 Enhanced Recovery Project No Violations inspect well.
0241863772 2013-03-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0296403605 2013-04-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Conduct fifteen minute pressure test on well. Passed test.
0317992423 2016-07-11 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0435473636 2005-04-28 Enhanced Recovery Project No Violations Injection well test.
0711403835 2007-05-31 Enhanced Recovery Project No Violations Injection and annulus pressure test. My records indicate NOV was in compliance on 12-29-2006. Annulus and injection pressure test passed on 5-31-2007.
0717260117 2011-10-17 Enhanced Recovery Project No Violations Inspect well.
0806115688 2007-11-01 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0816397193 2008-02-15 Enhanced Recovery Project Violations Noted Annulus and injection pressure test. Pressures are equal at 250 psi.
0882937262 2016-11-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The flow line nipple and well head fittings have been replaced recently.
0902308891 2017-01-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0929137830 2017-10-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0930009879 2005-12-22 Enhanced Recovery Project Violations Noted Test annulus and injection pressure. Test passed.
0931479432 2006-12-29 Enhanced Recovery Project No Violations Ran mini test on annulus. Pressure held at 320 for 15 minutes. Injection pressure is at 280 psi.
0949748884 2006-12-13 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equalized at 280 psi.
0961374603 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1051933561 2012-02-28 Enhanced Recovery Project No Violations Inspect Well. Run tubing and packer. Test well and pass.
1077263243 2003-08-14 Enhanced Recovery Project No Violations PRESSURE EQUALIZATION ON TUBING AND ANNULUS, REQUESTED MINI-TEST BE PERFORMED
1093670186 2020-4-10 0:00: ER No Violations
115180804 2018-10-9 0:00: ER No Violations
1182061871 2019-4-11 0:00: ER No Violations
1203604671 2008-02-21 Enhanced Recovery Project No Violations Retest of packer. Pressured annular side to 310 psi. After 15 minutes pressure did not decline. NOV in compliance.
1228919082 2008-12-10 Enhanced Recovery Project No Violations Pumped annulus to 400 psi and 0 psi decline in 15 minutes.
1240862370 2009-04-27 Enhanced Recovery Project Violations Noted Pressures are equal at 290 psi. Shut in well until repaired.
1241704446 2009-05-07 Enhanced Recovery Project No Violations Pulled stretch on packer and pressured up on annulus to 380 psi. 0 psi decline in 15 minutes. NOV in compliance.
1269951554 2010-03-30 Enhanced Recovery Project No Violations Injection and annulus pressure test. Pressures equal @ 290 psi.
12731387 2015-5-20 0:00: ER No Violations
1290777368 2010-11-26 Enhanced Recovery Project No Violations Injection and annulus pressure test. Leak inside box at injection line connection.
1302613247 2011-04-12 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1323161038 2006-04-06 Enhanced Recovery Project No Violations Injection and annulus pressure test. Constructed with 2 tubing cemented at Berea cap with 1 tubing on a packer.
1336062558 2018-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1386337099 2013-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Injector shut in upon Inspection. Pump shut down during inspection.
1400078249 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1447329518 2015-10-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head is in good condition.
1453530448 2012-06-04 Enhanced Recovery Project No Violations Inspect Well.
1559444924 2017-04-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
157131961 2004-4-22 0:00: ER No Violations
1574683779 2019-11-15 0:00 ER No Violations
1599136290 2020-7-9 0:00:0 ER No Violations
1599747668 2014-03-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1676242551 2009-09-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1725144047 2015-03-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1863166172 2018-08-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1928261572 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1935608020 2008-12-02 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equal at 270psi.
1937143116 2010-04-02 Enhanced Recovery Project No Violations Annulus and injection pressure test.
2028624400 2005-11-29 Enhanced Recovery Project Violations Noted Injection pressure and annulus pressures are equalized.
2048300739 2019-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2098477996 2016-01-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2124571792 2017-07-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
213176561 2012-2-6 0:00:0 ER No Violations
2138131597 2016-04-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
220121235 2011-7-12 0:00: ER No Violations
435473636 2005-4-28 0:00: ER No Violations 0.50
711403835 2007-5-31 0:00: ER No Violations 1.00
806115688 2007-11-1 0:00: ER No Violations 0.50
816397193 2008-2-15 0:00: ER No Violations 0.50
87984580 2012-9-20 0:00: ER No Violations
882937262 2016-11-2 0:00: ER No Violations
902308891 2017-1-9 0:00:0 ER No Violations
931479432 2006-12-29 0:00 ER No Violations 1.00
949748884 2006-12-13 0:00 ER No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0816397193 US-OH-129291 2008-02-15 Failure to conduct or pass mech. integrity test
0930009879 US-OH-130628 2005-11-30 Pollution/Contamination
0930009879 US-OH-130629 2005-11-30 Mechanical failure/contamination
0949748884 US-OH-130865 2006-12-13 Failure to conduct or pass mech. integrity test
1240862370 US-OH-106423 2009-04-27 Failure to conduct or pass mech. integrity test
1935608020 US-OH-119483 2008-11-25 Failure to conduct or pass mech. integrity test
2028624400 US-OH-120628 2005-11-30 Pollution/Contamination
2028624400 US-OH-120629 2005-11-30 Mechanical failure/contamination

For data sources see[5]