34-005-24134

Well Details

Well ID: 34-005-24134
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Lake Township
Operator Name: HARLEY DRILLING & PRODUCING LT
Well Pad ID:
Farm/Lease Name: DILGARD
License Status: Final Restoration
License Date: 2010-09-13
Spud Date: 2012-08-28
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 2012-10-08
Well Total Depth: 740.00 ft
Configuration: Vertical
Latitude: 40.710000
Longitude: -82.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-01 Proposed Formations:BEREA, Issued Date:12/1/2008, Expired Date:12/1/2009 6:00:00 AM, Drilling unit acres:160, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2010-09-13 Proposed Formations:BEREA, Issued Date:9/13/2010, Expired Date:9/12/2012 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:POOL
Construction Permit Expires 2012-09-12
Reached Total Depth 2012-10-08
Plugged/Abandoned 2012-10-11
Completion Report Received 2013-03-27
Record Last Modified 2017-10-24

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1737242781 2012-10-8 0:00: DD No Violations
-684944342 2012-10-5 0:00: DD No Violations
-79888792 2012-10-11 0:00 PB No Violations
0079888792 2012-10-11 Plug / Plug Back No Violations Plug well with 9 sac grout. Cement was delivered by the Orrville Trucking & Grading Co. The cement supplier is Cemex of Wampum, PA.
0684944342 2012-10-05 Drill / Deepen / Reopen No Violations Inspect drilling operation and collect GPS data. Current depth of drilling is 740 feet.
0966512745 2012-10-31 Final Restoration No Violations Inspect well. well cut off and buried. Pits filled and graded. Final restoration ok.
1348765748 2012-09-24 Drill / Deepen / Reopen No Violations I was on site to inspect the cementing of the 7 in. surface casing. Harley Drilling and Producing Co. had a truck mounted air/fluid rotary rig on site. A 10 in. hole was drilled to a depth of 330 ft. and 320 ft. of 7 in. surface casing was set in the hole. Petroset arrived on site and set up and began to pump fresh water in order to establish circulation and clean the hole of mud and debris. 75 bbl. of fresh water was pumped downhole and no circulation was observed. A water truck brought in another 75 bbl. of fresh water and it was pumped downhole and still no circulation was observed at the surface. At this point it was decided to have Petroset pump down three 50 lb. bags of cottonseed hulls and 500 lbs. of gel. Following that, Petroset began pumping the cement downhole. Within minutes I observed traces of cottonseed hulls and gel returning at the surface. I then observed the cement returning to the surface. Petroset pumped a total of 150 sks. of Class A cement. After approx. forty minutes, I observed a 20 ft. fallback of cement from the surface. Harley Drilling and Producing will use grout to bring the cement level back to the surface.
1737242781 2012-10-08 Drill / Deepen / Reopen No Violations Contacted by drilling operator to report that this well is a dry hole. Will schedule to plug well with 9 sac grout.
966512745 2012-10-31 0:00 FR No Violations

For data sources see[3]