Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: JENNINGS E & L | |
License Status: Storage Well | |
License Date: 1965-10-12 | |
Spud Date: 1965-11-01 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: 2649.00 ft | |
Configuration: Vertical | |
Latitude: 40.700000 | |
Longitude: -82.280000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Record Last Modified | 2013-05-23 |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1171928158 | 2013-12-10 0:00 | SO | No Violations | 0.50 |
-282512938 | 2018-10-4 0:00: | SO | No Violations | |
-444674231 | 2020-2-10 0:00: | SO | No Violations | |
-452507748 | 2016-10-4 0:00: | SO | No Violations | 0.50 |
-537820892 | 2017-5-5 0:00:0 | SO | No Violations | 0.50 |
-980335599 | 2014-10-7 0:00: | SO | No Violations | 0.50 |
0282512938 | 2018-10-04 | Storage Well | No Violations | ID is posted and the location is maintained. The annulus is open. The well is equipped with a separator and house gas connection at the pipeline tie in. |
0452507748 | 2016-10-04 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator. |
0537820892 | 2017-05-05 | Storage Well | No Violations | ID is posted and the location is maintained. The gate valve and annulus are open. The well is equipped with a separator and a house gas meter. |
0633251241 | 2019-04-23 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #10666 on 04/23/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-meter with 2-regulators. Well identification is clearly displayed. No problems were noted at the time of the inspection. |
0980335599 | 2014-10-07 | Storage Well | No Violations | ID posted, location maintained. |
1171928158 | 2013-12-10 | Storage Well | No Violations | ID is posted, location maintained; the well has the wrong API number on it. It is posted as 6-0085, however that permit is tied to a different Columbia Gas well number. The well is shut in. |
1346093712 | 2019-3-7 0:00:0 | SO | No Violations | |
1402654415 | 2015-07-13 | Storage Well | No Violations | The well is shut in at the side gate valve. The API posted on the well is 60085 which is incorrect. The location is maintained. The backside valve is open, no gas detected. |
633251241 | 2019-4-23 0:00: | SO | No Violations |