Well Details

Well ID: 34-007-20418
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Morgan Township
Operator Name: BOWEN THOMAS & JUDITH
Well Pad ID:
Farm/Lease Name: BOWEN UNIT
License Status: Domestic Well
License Date: 1971-05-06
Spud Date: 1971-05-05
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 1971-08-01
Well Total Depth: 3410.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -80.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1971-05-05
Completed 1971-08-01
Reached Total Depth 1971-08-01
CO 1986-03-12 2419 BOWEN CECIL,LIL,NORM&CHAR
Change of Owner 2019-01-04 Operator changed from 2419, BOWEN CECIL,LIL,NORM&CHAR to 10288, BOWEN THOMAS & JUDITH
Record Last Modified 2019-01-04

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3269 3371 22
3269 3371 22
3269 3371 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2220 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 BOWEN CECIL,LIL,NORM&CHAR 0.00 154.00 365
1993 CITATION ENERGY COMPANY 0.00 97.00 365
1995 BOWEN CECIL,LIL,NORM&CHAR 0.00 89.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 BOWEN CECIL,LIL,NORM&CHAR Brine 200 365
1993 CITATION ENERGY COMPANY Brine 59 365
1995 BOWEN CECIL,LIL,NORM&CHAR Brine 134 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1053607411 2020-5-26 0:00: PW No Violations
1540822598 2018-10-29 Exempt Well Pre Transfer No Violations I conducted an exempt pre-transfer inspection on this well. The well was equipped with a pumping unit. The valve on the tubing was closed. The valve on the 4.5 inch casing was open. The 2 inch line off the 4.5 inch casing was reduced into two, 1 inch lines with multiple regulators. Both 1 inch domestic lines were open. The standing water around the 4.5 inch casing was bubbling. There was a slight gas leak around the tubing packing, and a faint odor of gas was detected. The tank battery consisted of two 100 BBL tanks and a mechanical separator. There was no chart box on the sales line and the 2 inch line on the separator was closed. There was no dike around the 100 BBL tanks or separator. No identification was present at the well or tank battery. Access to the well was stable. I contacted landowner, Thomas Bowen. Mr. Bowen stated that the well was servicing his home and his mothers home with gas for domestic purposes. Mr. Bowen also stated that his mothers home was not on the same parcel as the well. The tank battery equipment was not going to be removed, so I informed Mr. Bowen that a dike would need installed around the tanks and legible identification would need to be installed at the well location.

For data sources see[9]