Well ID: 34-007-21486 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Ohio | |
County: Ashtabula | |
Municipality: Colebrook Township | |
Operator Name: LETOG LLC | |
Well Pad ID: | |
Farm/Lease Name: ARDO - CANTONESE UNIT | |
License Status: Producing | |
License Date: 1980-10-08 | |
Spud Date: 1980-11-21 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 1980-11-26 | |
Well Total Depth: 3765.00 ft | |
Configuration: Vertical | |
Latitude: 41.540000 | |
Longitude: -80.810000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-10-08 | 1966 PETROX INC GeoDate 10/8/80 |
Original Spud | 1980-11-21 | |
Completed | 1980-11-26 | |
Reached Total Depth | 1980-11-26 | |
Completion Report Received | 1981-03-19 | |
CO | 1995-01-24 | 1318 GRIFFIN LAUREL C GeoDate 10/8/80 |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1999-03-10 | 3576 | 3651 | 20 |
3576 | 3651 | 20 | |
3576 | 3651 | 20 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 72410 Gal | 64000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | GIANT PETROLEUM CORP | 4184.00 | 100.00 | 365 |
1986 | GIANT PETROLEUM CORP | 4076.00 | 185.00 | 365 |
1988 | GIANT PETROLEUM CORP | 2069.00 | 220.00 | 366 |
1989 | PETROX, INC | 119.00 | 0.00 | 30 |
1990 | PETROX, INC | 2782.00 | 134.00 | 365 |
1991 | PETROX, INC | 2630.00 | 82.00 | 365 |
1992 | PETROX, INC | 2083.00 | 41.00 | 365 |
1993 | PETROX, INC | 1636.00 | 175.00 | 365 |
1994 | PETROX, INC | 1111.00 | 59.00 | 365 |
2012 | LETOG LLC | 1287.00 | 64.00 | 366 |
2013 | LETOG LLC | 1073.00 | 70.00 | 365 |
2014 | LETOG LLC | 615.00 | 0.00 | 365 |
2015 | LETOG LLC | 608.00 | 0.00 | 365 |
2016 | LETOG LLC | 662.00 | 78.00 | 365 |
2017 | LETOG LLC | 644.00 | 84.00 | 365 |
2018 | LETOG LLC | 782.00 | 67.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | GIANT PETROLEUM CORP | Brine | 0 | 365 |
1986 | GIANT PETROLEUM CORP | Brine | 194 | 365 |
1988 | GIANT PETROLEUM CORP | Brine | 146 | 366 |
1989 | PETROX, INC | Brine | 0 | 30 |
1990 | PETROX, INC | Brine | 91 | 365 |
1991 | PETROX, INC | Brine | 64 | 365 |
1992 | PETROX, INC | Brine | 47 | 365 |
1993 | PETROX, INC | Brine | 77 | 365 |
1994 | PETROX, INC | Brine | 95 | 365 |
2012 | LETOG LLC | Brine | 42 | 366 |
2013 | LETOG LLC | Brine | 102 | 365 |
2014 | LETOG LLC | Brine | 112 | 365 |
2015 | LETOG LLC | Brine | 75 | 365 |
2016 | LETOG LLC | Brine | 0 | 365 |
2017 | LETOG LLC | Brine | 55 | 365 |
2018 | LETOG LLC | Brine | 98 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1652153112 | 2014-10-16 0:00 | PW | No Violations | |
-1794650839 | 2009-2-3 0:00:0 | PW | No Violations | |
-519952046 | 2014-9-5 0:00:0 | PW | No Violations | |
-554268877 | 2018-10-31 0:00 | PW | No Violations | |
0519952046 | 2014-09-05 | Production Wells | No Violations | Complaint # 4755, David Catanese. My inspection found the oil saturated soil around the well head has been removed and soil has been replaced. The area has been seeded and mulched. A working emergency phone number has been posted on identification sign at the tank battery area. I spoke with Ed Griffin, he told me they had to order the charcoal filter for the production tank and when it arrives they will install it. |
0554268877 | 2018-10-31 | Production Wells | No Violations | I conducted an inspection on this well. At the time of this inspection, the well was equipped with a pumping unit and in production. The tank battery consisted of one 210 BBL tank and a mechanical separator. The diked tank battery had legible identification. The lease access was stable. |
1299469418 | 2007-07-16 | Production Wells | No Violations | no violations . |
1407239075 | 2014-07-25 | Production Wells | Violations Noted | Complaint# 4755, David Catanese. I met with David Catanese and his wife at the tank battery area. I spoke with them to find they are smelling a strong odor of gas eminating from the tank battery area. While we were talking I would get a whiff of gas coming from the 210 barrel steel production tank every few minutes. They were also not saisfied with the maintenance of the tank battery area, [ cutting the tall weeds around the tank battery ]. I told them there was no action I could inforce for the company to cut the weeds down. There was a area on the 210 barrel steel tank that showed signs of a small leak located 7 from ground level on the west side. Further inspection of the well location found a pumping unit with fresh oil on the ground around the well casing in an area 4 x 8. I contacted the emergency phone number posted on the identification sign to get a recording saying the mail box was full and try again later. REMEDIAL ACTION REQUIRED TO CORRECT THE VIOLATIONS: Repair leak in 210 barrel production tank, install a charcoal filter on production tank, remove all oil saturated soil at well location and replace and establish vegetation growth, also post a working emergency phone number on the identification sign. |
1652153112 | 2014-10-16 | Production Wells | No Violations | Complaint # 4755, David Catanese. My inspection found a charcoal filter has been installed on the production tank. This resolves all of the violations with this well. This case is resolved. |
1794650839 | 2009-02-03 | Production Wells | No Violations | no violations . |
352114496 | 2019-5-16 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1407239075 | US-OH-111992 | 2014-08-13 | Well operation causing pollution and contamination | |
1407239075 | US-OH-111993 | 2014-08-13 | Well insufficiently equipped to prevent escape of oil and gas | |
1407239075 | US-OH-111994 | 2014-08-13 | Failure to legibly identify well |
For data sources see[9]