If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-007-22431 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.65,"lon":-80.75,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashtabula | |
Municipality: Lenox Township | |
Operator Name: C & D OIL & GAS LLC | |
Well Pad ID: | |
Farm/Lease Name: HLH DRILLING INC | |
License Status: Producing | |
License Date: 1983-11-16 | |
Spud Date: 1984-03-09 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: 1984-03-14 | |
Well Total Depth: 3704.00 ft | |
Configuration: Vertical | |
Latitude: 41.650000 | |
Longitude: -80.750000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1983-11-16 | 1464 HLH DRILLING INC GeoDate 11/16/83 |
Oil and Gas | 1983-11-16 | Issued Date 11/16/83 Expired Date 5/14/84 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03704 Proposed Drill Depth 03704 |
Original Spud | 1984-03-04 | |
Completed | 1984-03-14 | |
Reached Total Depth | 1984-03-14 | |
Construction Permit Expires | 1984-05-14 | |
Completion Report Received | 1984-06-15 | |
CO | 1992-01-02 | 3538 FREMONT ENERGY INC GeoDate 11/16/83 |
Change of Owner | 2018-03-06 | Operator changed from 3538, FREMONT ENERGY INC to 10067, C & D OIL & GAS LLC |
Record Last Modified | 2018-03-06 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3500 | 3563 | 11 |
3500 | 3563 | 11 | |
3500 | 3563 | 11 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 60000 | FRAC;H2O,SAND,N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | HLH DRILLING INC | 14832.00 | 99.00 | 0 |
1990 | FREMONT ENERGY INC | 2856.00 | 156.00 | 365 |
1991 | FREMONT ENERGY INC | 1830.00 | 96.00 | 365 |
1993 | FREMONT ENERGY INC | 1283.00 | 81.00 | 365 |
1994 | RIDGWAY REALTY & LAND INC | 633.00 | 72.00 | 365 |
1995 | FREMONT ENERGY INC | 91.00 | 0.00 | 151 |
1996 | FREMONT ENERGY INC | 0.00 | 0.00 | 0 |
1997 | FREMONT ENERGY INC | 0.00 | 0.00 | 0 |
1998 | FREMONT ENERGY INC | 0.00 | 0.00 | 0 |
1999 | FREMONT ENERGY INC | 0.00 | 0.00 | 365 |
2000 | FREMONT ENERGY INC | 591.00 | 0.00 | 365 |
2001 | FREMONT ENERGY INC | 111.00 | 0.00 | 365 |
2002 | FREMONT ENERGY INC | 0.00 | 0.00 | 365 |
2003 | FREMONT ENERGY INC | 0.00 | 0.00 | 0 |
2004 | FREMONT ENERGY INC | 0.00 | 0.00 | 365 |
2005 | FREMONT ENERGY INC | 0.00 | 0.00 | 365 |
2006 | FREMONT ENERGY INC | 55.00 | 70.00 | 365 |
2007 | FREMONT ENERGY INC | 1148.00 | 28.00 | 365 |
2010 | FREMONT ENERGY INC | 525.00 | 38.00 | 365 |
2012 | FREMONT ENERGY INC | 0.00 | 0.00 | 366 |
2013 | FREMONT ENERGY INC | 0.00 | 0.00 | 365 |
2014 | FREMONT ENERGY INC | 0.00 | 33.00 | 365 |
2015 | FREMONT ENERGY INC | 1.00 | 0.00 | 365 |
2016 | FREMONT ENERGY INC | 123.00 | 0.00 | 365 |
2017 | FREMONT ENERGY INC | 0.00 | 0.00 | 365 |
2018 | C & D OIL & GAS LLC | 350.00 | 0.00 | 150 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | HLH DRILLING INC | Brine | 170 | 0 |
1990 | FREMONT ENERGY INC | Brine | 133 | 365 |
1991 | FREMONT ENERGY INC | Brine | 188 | 365 |
1993 | FREMONT ENERGY INC | Brine | 207 | 365 |
1994 | RIDGWAY REALTY & LAND INC | Brine | 133 | 365 |
1995 | FREMONT ENERGY INC | Brine | 0 | 151 |
1996 | FREMONT ENERGY INC | Brine | 0 | 0 |
1997 | FREMONT ENERGY INC | Brine | 0 | 0 |
1998 | FREMONT ENERGY INC | Brine | 0 | 0 |
1999 | FREMONT ENERGY INC | Brine | 0 | 365 |
2000 | FREMONT ENERGY INC | Brine | 21 | 365 |
2001 | FREMONT ENERGY INC | Brine | 11 | 365 |
2002 | FREMONT ENERGY INC | Brine | 53 | 365 |
2003 | FREMONT ENERGY INC | Brine | 0 | 0 |
2004 | FREMONT ENERGY INC | Brine | 0 | 365 |
2005 | FREMONT ENERGY INC | Brine | 0 | 365 |
2006 | FREMONT ENERGY INC | Brine | 60 | 365 |
2007 | FREMONT ENERGY INC | Brine | 234 | 365 |
2010 | FREMONT ENERGY INC | Brine | 118 | 365 |
2012 | FREMONT ENERGY INC | Brine | 0 | 366 |
2013 | FREMONT ENERGY INC | Brine | 58 | 365 |
2014 | FREMONT ENERGY INC | Brine | 70 | 365 |
2015 | FREMONT ENERGY INC | Brine | 64 | 365 |
2016 | FREMONT ENERGY INC | Brine | 0 | 365 |
2017 | FREMONT ENERGY INC | Brine | 0 | 365 |
2018 | C & D OIL & GAS LLC | Brine | 37 | 150 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1412956379 | 2018-8-6 0:00:0 | PW | No Violations | |
1334057372 | 2007-07-31 | Production Wells | No Violations | no violations . |
1412956379 | 2018-08-06 | Production Wells | No Violations | At the time of this inspection, the well was equipped with a pumping unit and the valve on the 2 inch flow line off of the tubing was open. There was a domestic line plumbed off of the 4.5 inch casing with two regulators and a drip bottle. The tank battery was comprised of two 210 BBL tanks, one 100 BBL tank and two mechanical separators. Valves on the separators were open and the charts showed production. The tank battery was shared with well 2-2435. The tank battery was diked and had legible signage. The lease access was stable. |
For data sources see[9]