X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-24421

Well Details

Well ID: 34-007-24421
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Trumbull Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: HOLY UNIT
License Status: Producing
License Date: 2006-06-21
Spud Date: 2007-01-13
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2007-01-29
Well Total Depth: 6141.00 ft
Configuration: Vertical
Latitude: 41.670000
Longitude: -80.970000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-06-21 Proposed Formations:ROSE RUN, Issued Date:6/21/2006, Expired Date:6/21/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EOUT
Completed 2007-01-29 RBDMS Rec
Reached Total Depth 2007-01-29 RBDMS Rec
Completion Report Received 2007-03-05 RBDMS Rec
Change of Owner 2007-04-27 Operator changed from 28, CGAS EXPLORATION to 7578, ENERVEST OPERATING LLC
Construction Permit Expires 2007-06-21 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-06-21 5942 5958 48
5942 5958 48
5942 5958 48

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1200 Gal 0 FE-CONTROL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 ENERVEST OPERATING LLC 44437.00 571.00 275
2008 ENERVEST OPERATING LLC 71099.00 462.00 365
2009 ENERVEST OPERATING LLC 68330.00 157.00 365
2010 ENERVEST OPERATING LLC 25632.00 63.00 365
2011 ENERVEST OPERATING LLC 12322.00 0.00 0
2012 ENERVEST OPERATING LLC 11361.00 69.00 366
2013 ENERVEST OPERATING LLC 8487.00 0.00 365
2014 ENERVEST OPERATING LLC 8653.00 63.00 365
2015 ENERVEST OPERATING LLC 3022.00 0.00 365
2016 ENERVEST OPERATING LLC 2211.00 121.00 366
2017 ENERVEST OPERATING LLC 3714.00 110.00 365
2018 ENERVEST OPERATING LLC 5375.00 153.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 ENERVEST OPERATING LLC Brine 20 275
2008 ENERVEST OPERATING LLC Brine 21 365
2009 ENERVEST OPERATING LLC Brine 25 365
2010 ENERVEST OPERATING LLC Brine 10 365
2011 ENERVEST OPERATING LLC Brine 34
2012 ENERVEST OPERATING LLC Brine 5 366
2013 ENERVEST OPERATING LLC Brine 72 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 14 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 6 365
2018 ENERVEST OPERATING LLC Brine 1 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1509011873 2007-1-23 0:00: DD No Violations
-1528794286 2007-9-24 0:00: PW No Violations
-1755700475 2009-6-23 0:00: PL No Violations
-840567073 2007-10-24 0:00 PW No Violations
0840567073 2007-10-24 Production Wells No Violations Follow-up Case# WW007-001 . Gas reading in waterwell bore was 0% LEL . Reading inside home at spigot showed 0% LEL with water running . No vilations .
1201634357 2007-09-18 Production Wells No Violations Case# WW07-001 , Vogt , Joseph L. . Inspection of well showed anulus of 4.5 casing has a 2 pipe with valve which is open . There is small amount of gas venting from anulus . Well is located on south side of Trumbull road from complaintants home on north side of Trumbull road aprox. 350 . I met with Mr. & Mrs. Vogt at their home , { 6207 Trumbull road } . They advised me that the Fire Dept. had been at their home last week and had high gas readings in their home .I went inside home to find 0 LEL in home . I then went to kitchen sink and still had 0 LEL . I turned water on to find 36% LEL for approx. 1 min. when the reading went to 0% LEL . I took readings several times running water till the percent of LEL was 0% . The water well was not accessible from surface, it was paved over with asphalt . Mr. Vogt said he would uncover waterwell for inspection . I then took water samples from outdoor spigot which bypassed conditioning and filter systems . Samples were sent to lab for analysis .
1509011873 2007-01-23 Drill / Deepen / Reopen No Violations Pep drilling at 4352 .
1528794286 2007-09-24 Production Wells No Violations Follow-up , Case# WW07-001 . Mr. Vogt had uncovered waterwell . Well was 35 deep , the static level of water was approx. 8-10 from surface . I took reading from wellbore with gas meter to find 0% LEL . I then took readings at inside spigot with water running { note. There was 0% LEL with water not running } to find 30% LEL for several seconds then readings dropped to 0% LEL . I advised Mr. Vogt the cause of high LEL readings at spigot while running were not coming from waterwell , the source could be from water systems inside home . I took water samples which were sent to Lab for analysis .
1569714539 2007-10-10 Production Wells No Violations Follow-up , Case# WW07-001 . Gas reading from waterwell bore showed 0% LEL . Mr. Vogt had replaced water heater since last inspection . The gas reading at inside spigot with water running { Note; reading without water running was 0% LEL . } showed 12-15% LEL for 5-10 sec. When it dropped to 0% LEL . I took water samples which were sent to Lab for analysis . There is no further help or advice I can provide at this time . CASE RESOLVED .
1755700475 2009-06-23 Preliminary Restoration No Violations no violations .
733582799 2019-7-9 0:00:0 PW No Violations

For data sources see[9]

References