If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-007-24560 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.52,"lon":-80.72,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashtabula | |
Municipality: Colebrook Township | |
Operator Name: US ENERGY OH LLC | |
Well Pad ID: | |
Farm/Lease Name: DUMITRAS UNIT | |
License Status: Producing | |
License Date: 2017-02-14 | |
Spud Date: 2017-02-28 | |
Spud Drilling Contractor: US ENERGY DRILLING LLC | |
Final Drill Date: 2017-03-27 | |
Well Total Depth: 6300.00 ft | |
Configuration: Horizontal | |
Latitude: 41.520000 | |
Longitude: -80.720000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-02-14 | Proposed Formations:WHITE CLINTON, Issued Date:2/14/2017, Expired Date:2/14/2019 12:00:00 PM, Drilling unit acres:346.8, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2017-03-27 | |
Correction to Well | 2017-04-07 | UPDATE ACREAGE/DRILL UNIT-ALE |
Correction to Well | 2017-05-22 | UPDATE ACREAGE/TARGET/TAKEPOINTS PER AS-DRILLED PLAT RCVD 5-19-17 ALE |
Correction to Well | 2017-05-26 | as drilled plat recvd |
Construction Permit Expires | 2019-02-14 | |
Record Last Modified | 2019-06-07 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-09-18 | 4300 | 4360 | 50 |
2017-09-18 | 6200 | 6260 | 50 |
6200 | 6260 | 50 | |
4300 | 4360 | 50 | |
4300 | 4360 | 50 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2019-06-16 | H2O | 15 | 15021 Bbl | 4480 | Reliance Well Service | SEE RECORD FOR DETAILS |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | US ENERGY OH LLC | 2715.00 | 920.00 | 74 |
2018 | US ENERGY OH LLC | 6964.00 | 3301.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2017 | US ENERGY OH LLC | Brine | 2433 | 74 |
2018 | US ENERGY OH LLC | Brine | 4441 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1102208634 | 2017-7-26 0:00: | PL | No Violations | |
-1511474425 | 2018-5-1 0:00:0 | PW | No Violations | 1.00 |
-1522599607 | 2017-2-28 0:00: | DD | No Violations | |
-156222368 | 2017-3-17 0:00: | DD | No Violations | |
-1857400187 | 2017-3-10 0:00: | DD | No Violations | |
-197990849 | 2017-3-6 0:00:0 | DD | No Violations | |
-1984214095 | 2019-6-3 0:00:0 | PW | No Violations | |
-2001993226 | 2017-6-28 0:00: | DD | No Violations | 1.00 |
-229248965 | 2017-3-14 0:00: | DD | No Violations | |
-348594975 | 2017-3-20 0:00: | DD | No Violations | |
-644796347 | 2017-10-3 0:00: | PW | No Violations | |
-681708554 | 2017-3-3 0:00:0 | DD | No Violations | |
0045152654 | 2017-03-21 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig drilling at 4289 feet in the horizontal portion of the well bore. |
0150235625 | 2017-03-02 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig drilling at 281 feet on the surface hole bore. |
0156222368 | 2017-03-17 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig was at a depth of 4042 feet. The rig was in the process in tripping the drill pipe from the well to change over to a fluid bit. The well began making fluid which forced them to change from air drilling to fluid drilling. |
0197990849 | 2017-03-06 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig was drilling at 2200 feet on the intermediate hole bore. |
0229248965 | 2017-03-14 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig was at the depth of 3450 feet and was in the process in tripping the drilling bit from the well. |
0348594975 | 2017-03-20 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig was still at a depth of 4042 feet and was still out of the well with the drill pipe. They were waiting on down hole drilling equipment. |
0410255202 | 2017-03-10 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig had drilled out the casing shoe and was in the process in tripping the drill pipe from the well. The company was going to shut-down for the weekend after they had removed the drill pipe from the well. |
0644796347 | 2017-10-03 | Production Wells | No Violations | U S Energy personnel was setting the electric pump jack and connecting it to the polish rod. I requested that U S Energy check the stock tanks for adequate capacity once the unit was started. There was approximately 400 barrels of room. No violations identified during this inspection. |
0681708554 | 2017-03-03 | Drill / Deepen / Reopen | No Violations | I was n on site to witness the pressure test on the BOP. They pressured up on the annular space of the drill pipe to 400 PSI and then closed in the annulus for 15 minutes. There was no loss of pressure in the fifteen minutes. The test passed. |
1016009492 | 2017-03-07 | Drill / Deepen / Reopen | No Violations | I arrived on site to find the drilling rig drilling at 2610 feet on the intermediate hole bore. |
1102208634 | 2017-07-26 | Preliminary Restoration | No Violations | I inspected the Dumtiras pad for the preliminary restoration status. I found that the pits were closed. The location was grade to prevent standing water. The road and pads perimeter had not been seeded at the time of my inspection. The timber was stacked on the east side of location per the Landowners request ( source Cary LeShock, U S Energy ). I inquired about the scrub brush and was referred to Harry ( construction manager ). The scrub brush needs to removed or chipped into the woods for habitat. Concrete barriers were placed to isolate the live wells. A 2408 GPU separator was on location awaiting tank battery construction. No violations identified during this inspection. |
150235625 | 2017-3-2 0:00:0 | DD | No Violations | |
1511474425 | 2018-05-01 | Production Wells | No Violations | The Dumitras 1- H well is equipped with electric pumping well. The tank battery was shared with the Dumitras 2- H well ( 34-007-2-4559 ). The tank battery was comprised of three (3) 210 barrel stock tanks and a Gas Production Unit ( GPU ). The tank pad was surrounded by a earthen dike. |
1522599607 | 2017-02-28 | Drill / Deepen / Reopen | No Violations | I arrived on site to find U S Energy drilling rig# 9 drilling the conductor hole. They were 30 feet deep at the time of my inspection. |
1857400187 | 2017-03-10 | Drill / Deepen / Reopen | No Violations | I was on site to witness the pressure test on the blind and pipe rams. They pressured up on the annulus of the drill pipe to 400 PSI and the shut-in the annulus of the drill pipe for 15 minutes. There was no lost of pressure after 15 minutes. The test passed. |
2001993226 | 2017-06-28 | Drill / Deepen / Reopen | No Violations | I performed a site inspection on this location. They are preparing to frac the well. The well are fraced. The pits are in good condition with ample room before over flowing. Location is well maintained and clean. |
410255202 | 2017-3-10 0:00: | DD | No Violations | |
45152654 | 2017-3-21 0:00: | DD | No Violations |
For data sources see[9]