Well ID: 34-007-60339
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: HISTORIC OWNER
Well Pad ID:
Farm/Lease Name: CONNEAUT TOWNSHIP PARK
License Status: Final Restoration
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 41.960000
Longitude: -80.560000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Changed to Orphan Well Ready 2007-08-01 Changed Well To Orphan Ready
Well Added to System 2007-08-22 I&O CASE # 2007 08 006; NO PREVIOUS RECORD OF WELL; WILL NEED TO CORRECT THE LOCATION WHEN GET A GPS WELL LOCATION.
Record Last Modified 2019-03-25 I&O CASE # 2007 08 006; NO PREVIOUS RECORD OF WELL; WILL NEED TO CORRECT THE LOCATION WHEN GET A GPS WELL LOCATION. UPDATED COORDINATES PER DOGRM SURVEYOR ALE 12/13/17.

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1201058012 2019-2-26 0:00: OR No Violations
-1648437560 2017-8-22 0:00: OR No Violations
-1818426175 2020-7-10 0:00: FR No Violations
-1943603245 2015-10-21 0:00 OR No Violations 3.00
-2039582683 2018-6-13 0:00: OR No Violations
-2095495595 2017-11-21 0:00 OR No Violations
-459238090 2019-2-22 0:00: OR No Violations
-533072020 2015-8-18 0:00: OR No Violations
-644957246 2017-11-6 0:00: OR No Violations
-687033067 2017-10-25 0:00 OR No Violations
0533072020 2015-08-18 Orphan No Violations On site with Orphan Well Manager, Gene Chini, to evaluate the well and site conditions for possible well plugging by the Orphan Well program. Cement is evident between the tubing and casing and gas is leaking through the cement. See earlier inspection reports and the case file. Conneaut Township Park initially contacted the Division in 1997 to request the leaking well be plugged, Case # 97-003. The well is an area of known Shale wells. The Division of Oil and Gas and the Ohio Fuel Gas maps do not show a well at this location.
0644957246 2017-11-06 Orphan No Violations My inspection found no changes since my last inspection.
1201058012 2019-02-26 Orphan No Violations At the time of my inspection I was on location with inspector Kevin Perry. He stated that the well was dry of fluid and the well was gaged at 16 PSI. Hydro carbon well service pulled 218 feet of tubing out of well. Timco Inc. ran a collar locator down well and got to the total depth of 240 feet. On site was a service rig, one steel pit open top, one 100 BBL production tank, and a mini excavator.
1326972802 2017-03-06 Orphan No Violations Todays inspection was conducted for the Technical Team to review the well site. The water level inside the well vault is now covering the top of the well and the tubing. Bubbling is evident in the SW corner of the vault.
1443539703 2015-07-31 Orphan No Violations Conneaut Township Park initially contacted the Division in 1997 regarding this leaking gas well. The well was referred into the Orphan Well Program, complaint # 97-003. The well is in the NW corner of a gravel parking lot approximately 6 from the edge of the park drive. There is a playground located approximately 30 north of the well. This follow--up on the collar it was difficult to accurately determine the true diameter. Cemented in this casing is 2.75 diameter tubing. There is a bull plug installed in the tubing collar which is equipped with a fitting for a pressure gauge. The fitting is closed and has a plug in it. The well was metered for natural gas and the Sperian meter, equipped with piping and the filter, detected 10% LEL/0 ppm H2S at the cement around the tubing.

There is a flat weight/balance regulator in the east side of the vault that is disconnected from the well. These regulators may contain mercury and should be handled appropriately. There is an old steel service line goes into the ground from the regulator. This line used to run to an old gas grill that was located NE of the well and also to the house that is located to the south of the well, at the top of the hill. U

1471971882 2016-08-01 Orphan No Violations The Conneaut Township Park #1 well has been submitted to the Orphan Well program for possible plugging. The well is located in a parking area across from a playground. The well is leaking gas and todays inspection was conducted to check the gas level at the well site. A slight gas odor is evident in the air around the well vault. The vault is covered with a steel lid and my Sperian gas meter showed a 100% LEL/0 ppm H2S reading 4 from the lip of the north side of the steel lid. Gas was not detected by my meter at farther distances. I reviewed the status of the well plugging and possible submittal into the Landowner Pass Through Program with the Park Manager, Bruce Mitchell.
1501694053 2017-08-01 Orphan No Violations No changes since my last inspection.
1550663179 2019-2-19 0:00: OR No Violations
1551104397 2019-2-20 0:00: OR No Violations
1551210537 2019-2-21 0:00: OR No Violations
1648437560 2017-08-22 Orphan No Violations My inspection found no changes since my last inspection.
1923891410 2017-8-22 0:00: OR No Violations
1943603245 2015-10-21 Orphan No Violations On location with Insp. Scott to view site and discuss possible scenarios for this well.
2039582683 2018-06-13 Orphan No Violations My inspection found no changes since my last inspection.
2095495595 2017-11-21 Orphan No Violations My inspection found no changes since my last inspection.
834287054 2017-8-1 0:00:0 OR No Violations
902348415 2019-2-25 0:00: OR No Violations

For data sources see[3]