If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-009-21439 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.38,"lon":-81.94,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Athens | |
Municipality: Bern Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: STARLIN HOWARD | |
License Status: Producing | |
License Date: 1962-12-14 | |
Spud Date: 1962-12-19 | |
Spud Drilling Contractor: | |
Final Drill Date: 1962-12-31 | |
Well Total Depth: 1627.00 ft | |
Configuration: Vertical | |
Latitude: 39.380000 | |
Longitude: -81.940000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1962-12-19 | GL=762.1 |
Completed | 1962-12-31 | GL=762.1 |
Reached Total Depth | 1962-12-31 | GL=762.1 |
CO | 1991-06-20 | 3969 KAPLAN INTERESTS INC |
Change of Owner | 2004-07-08 | Operator changed from 3969, KAPLAN INTERESTS INC to 7671, KEITO GAS INC |
Change of Owner | 2016-11-03 | Operator changed from 7671, KEITO GAS INC to 9651, AM-TEK OIL INC |
Record Last Modified | 2016-11-03 | GL=762.1 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 900 Bbl | 17000 | RP. 24 HRS. |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TRIPLE GAS CO | 360.00 | 235.00 | 0 |
1987 | GLENEAYRE RESOURCES INC | 377.00 | 70.00 | 365 |
1988 | GLENEAYRE RESOURCES INC | 0.00 | 104.00 | 212 |
1989 | GLENEAYRE RESOURCES INC | 331.00 | 47.00 | 365 |
1990 | GLENEAYRE RESOURCES INC | 303.00 | 52.00 | 365 |
1991 | KAPLAN INTERESTS INC | 0.00 | 57.00 | 210 |
1992 | KAPLAN INTERESTS INC | 452.00 | 112.00 | 365 |
1993 | KAPLAN INTERESTS INC | 168.00 | 49.00 | 365 |
1994 | KAPLAN INTERESTS INC | 177.00 | 91.00 | 365 |
1995 | KAPLAN INTERESTS INC | 221.00 | 62.00 | 365 |
1996 | KAPLAN INTERESTS INC | 151.00 | 88.00 | 365 |
1997 | KAPLAN INTERESTS INC | 121.00 | 86.00 | 365 |
1998 | KAPLAN INTERESTS INC | 92.00 | 11.00 | 365 |
1999 | KAPLAN INTERESTS INC | 107.00 | 28.00 | 365 |
2000 | KAPLAN INTERESTS INC | 95.00 | 0.00 | 365 |
2001 | KAPLAN INTERESTS INC | 55.00 | 50.00 | 365 |
2002 | KAPLAN INTERESTS INC | 68.00 | 30.00 | 365 |
2003 | KAPLAN INTERESTS INC | 37.00 | 20.00 | 365 |
2004 | KEITO GAS INC | 4.00 | 0.00 | 180 |
2005 | KEITO GAS INC | 20.00 | 17.00 | 365 |
2006 | KEITO GAS INC | 18.00 | 38.00 | 365 |
2007 | KEITO GAS INC | 18.00 | 21.00 | 365 |
2008 | KEITO GAS INC | 32.00 | 32.00 | 365 |
2009 | KEITO GAS INC | 22.00 | 21.00 | 365 |
2010 | KEITO GAS INC | 36.00 | 51.00 | 365 |
2011 | KEITO GAS INC | 59.00 | 21.00 | 365 |
2012 | KEITO GAS INC | 34.00 | 48.00 | 366 |
2013 | KEITO GAS INC | 35.00 | 40.00 | 365 |
2014 | KEITO GAS INC | 29.00 | 29.00 | 365 |
2015 | KEITO GAS INC | 63.00 | 0.00 | 365 |
2016 | KEITO GAS INC | 1.00 | 18.00 | 270 |
2017 | AM-TEK OIL INC | 13.00 | 55.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TRIPLE GAS CO | Brine | 0 | 0 |
1987 | GLENEAYRE RESOURCES INC | Brine | 243 | 365 |
1988 | GLENEAYRE RESOURCES INC | Brine | 360 | 212 |
1989 | GLENEAYRE RESOURCES INC | Brine | 174 | 365 |
1990 | GLENEAYRE RESOURCES INC | Brine | 204 | 365 |
1991 | KAPLAN INTERESTS INC | Brine | 0 | 210 |
1992 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1993 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1994 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1995 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1996 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1997 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1998 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1999 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
2000 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
2001 | KAPLAN INTERESTS INC | Brine | 200 | 365 |
2002 | KAPLAN INTERESTS INC | Brine | 83 | 365 |
2003 | KAPLAN INTERESTS INC | Brine | 9 | 365 |
2004 | KEITO GAS INC | Brine | 0 | 180 |
2005 | KEITO GAS INC | Brine | 11 | 365 |
2006 | KEITO GAS INC | Brine | 0 | 365 |
2007 | KEITO GAS INC | Brine | 40 | 365 |
2008 | KEITO GAS INC | Brine | 14 | 365 |
2009 | KEITO GAS INC | Brine | 6 | 365 |
2010 | KEITO GAS INC | Brine | 5 | 365 |
2011 | KEITO GAS INC | Brine | 0 | 365 |
2012 | KEITO GAS INC | Brine | 19 | 366 |
2013 | KEITO GAS INC | Brine | 33 | 365 |
2014 | KEITO GAS INC | Brine | 36 | 365 |
2015 | KEITO GAS INC | Brine | 62 | 365 |
2016 | KEITO GAS INC | Brine | 270 | |
2017 | AM-TEK OIL INC | Brine | 62 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1771877382 | 2018-6-7 0:00:0 | PW | No Violations | 0.40 |
-2024444936 | 2020-8-4 0:00:0 | PW | No Violations | 0.40 |
-395956318 | 2018-5-17 0:00: | PW | No Violations | 0.20 |
-555659052 | 2018-5-29 0:00: | PW | No Violations | 0.30 |
0095909682 | 2018-12-03 | Production Wells | No Violations | This well was issued a compliance notice that required burying the flowline that ran through the middle of the field to the tank battery. The line has still not been buried. I texted Andrew the owner of Am-Tek and asked when he thought this would get accomplished. |
0395956318 | 2018-05-17 | Production Wells | No Violations | The pipeline is still not buried through the pasture. |
0555659052 | 2018-05-29 | Production Wells | No Violations | The flowline is still on top of the ground through the pasture. |
1182866004 | 2007-06-22 | Production Wells | Violations Noted | An inspection found oil pooling inside the tank battery dike. Oil covered an area of approximately 4 feet by 15 feet. Several saturated pads were laying inside the dike. However, the clean-up was incomplete. |
1184093359 | 2007-07-10 | Production Wells | No Violations | The clean-up was completed. The tank battery is in compliance. |
1546316740 | 2018-07-11 | Production Wells | No Violations | The line is still not buried. Andrew the owner said the work would be completed the middle of August. I emailed him to confirm this. |
1570726040 | 2019-10-10 0:00 | PW | No Violations | 1.00 |
1677038471 | 2020-10-13 0:00 | PW | No Violations | 0.30 |
1766347849 | 2018-05-02 | Production Wells | Violations Noted | This well is equipped with a pumping unit, tubing, rods and an electric motor. There was good identification at the well site. The flowline has been replaced and the flowline was placed on top of the ground through the pasture. This line will need buried. I spoke with Andrew Ulrich owner of the company at 10:15 am on 5/4/18 about this well and others that were issued violations. |
1771877382 | 2018-06-07 | Production Wells | No Violations | I was accompanied to this well by Andrew Ulrich. He plans on burying the lines through the field the week of the 15th in August. |
1817658953 | 2018-08-14 | Production Wells | No Violations | The flowline across the pasture has yet to be buried. There is an elbow leaking fluids onto the ground causing a small scalded area this will also need corrected. I called Andrew to discuss this violation and steps to resolve it. |
1888535560 | 2018-06-05 | Production Wells | No Violations | The flowline was still on top of the ground through the pasture. I called Andrew Ulrich the owner of Am-Tek Oil and he said that he had already rented equipment and planned on burying the line August 15th. |
95909682 | 2018-12-3 0:00: | PW | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1182866004 | US-OH-104847 | 2007-06-26 | Well operation causing pollution and contamination | |
1766347849 | US-OH-117569 | 2018-05-09 | 9-10-05 | Failure to properly bury pipeline |
For data sources see[8]