34-009-21512

Well Details

Well ID: 34-009-21512
Loading map...
Country: United States
State: Ohio
County: Athens
Municipality: Bern Township
Operator Name: DENNIS NORMA JEAN ZIEGLER
Well Pad ID:
Farm/Lease Name: ZIEGLER ROY
License Status: Domestic Well
License Date: 2005-02-08
Spud Date: 1964-08-01
Spud Drilling Contractor:
Final Drill Date: 1964-11-10
Well Total Depth: 1464.00 ft
Configuration: Vertical
Latitude: 39.370000
Longitude: -81.940000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1964-08-01
Completed 1964-11-10
Reached Total Depth 1964-11-10
Change of Owner 2004-07-08 Operator changed from 3969, KAPLAN INTERESTS INC to 7671, KEITO GAS INC
APP 2005-02-08 Proposed Formations:BEREA, Issued Date:2/8/2005, Expired Date:2/8/2006 6:00:00 AM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2005-04-05 Operator changed from 7671, KEITO GAS INC to 6431, DENNIS NORMA JEAN ZIEGLER
Construction Permit Expires 2006-02-08
Record Last Modified 2012-06-01

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1415 1440 0
1415 1440 0
1415 1440 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 700 Bbl 20000 RP. 24 HRS.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 GLENEAYRE RESOURCES INC 168.00 89.00 180
1988 GLENEAYRE RESOURCES INC 219.00 124.00 365
1989 GLENEAYRE RESOURCES INC 299.00 63.00 365
1990 GLENEAYRE RESOURCES INC 304.00 110.00 365
1991 KAPLAN INTERESTS INC 84.00 0.00 210
1992 KAPLAN INTERESTS INC 299.00 0.00 365
1993 KAPLAN INTERESTS INC 277.00 0.00 365
1994 KAPLAN INTERESTS INC 260.00 0.00 365
1995 KAPLAN INTERESTS INC 168.00 0.00 365
1996 KAPLAN INTERESTS INC 218.00 0.00 365
1997 KAPLAN INTERESTS INC 203.00 0.00 365
1998 KAPLAN INTERESTS INC 175.00 0.00 365
1999 KAPLAN INTERESTS INC 150.00 19.00 365
2000 KAPLAN INTERESTS INC 30.00 0.00 365
2001 KAPLAN INTERESTS INC 0.00 0.00 365
2002 KAPLAN INTERESTS INC 0.00 0.00 365
2003 KAPLAN INTERESTS INC 0.00 0.00 365
2004 KEITO GAS INC 0.00 3.00 180
2005 KEITO GAS INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 GLENEAYRE RESOURCES INC Brine 86 180
1988 GLENEAYRE RESOURCES INC Brine 167 365
1989 GLENEAYRE RESOURCES INC Brine 114 365
1990 GLENEAYRE RESOURCES INC Brine 102 365
1991 KAPLAN INTERESTS INC Brine 0 210
1992 KAPLAN INTERESTS INC Brine 0 365
1993 KAPLAN INTERESTS INC Brine 0 365
1994 KAPLAN INTERESTS INC Brine 0 365
1995 KAPLAN INTERESTS INC Brine 0 365
1996 KAPLAN INTERESTS INC Brine 0 365
1997 KAPLAN INTERESTS INC Brine 0 365
1998 KAPLAN INTERESTS INC Brine 0 365
1999 KAPLAN INTERESTS INC Brine 0 365
2000 KAPLAN INTERESTS INC Brine 0 365
2001 KAPLAN INTERESTS INC Brine 0 365
2002 KAPLAN INTERESTS INC Brine 0 365
2003 KAPLAN INTERESTS INC Brine 0 365
2004 KEITO GAS INC Brine 0 180
2005 KEITO GAS INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1057757821 2020-8-11 0:00: PW No Violations 0.30
-1284097860 2020-10-13 0:00 PW No Violations 0.40
-1823869102 2017-8-22 0:00: PW No Violations 0.50
-1984637949 2018-4-12 0:00: PW No Violations 0.50
-393761919 2017-9-26 0:00: PW No Violations 0.50
-604484748 2017-9-20 0:00: PW No Violations 0.50
-861912327 2004-6-18 0:00: PW No Violations
0037432173 2018-05-04 Production Wells No Violations The dike is still cut and allowing water to escape the dike. The contamination has been removed at the wellhead. Nobody was home when I stopped.
0073981558 2004-03-10 Production Wells Violations Noted Well was producing at the time. The well was equipped with a pump jack. No storage tank present. Well ID faded completely. Well Lat & Long update.
0380569542 2017-09-07 Production Wells No Violations No identification has been posted at the well as of yet.
0393761919 2017-09-26 Production Wells No Violations Well is identified and vegetation that was contaminated has been cut down.
0604484748 2017-09-20 Production Wells No Violations I spoke with Mrs. Ziegler last week and she stated that the identification at the well-heads will be posted by the end of next week. I went to check on them and as of today the identification was not posted.
0861912327 2004-06-18 Production Wells No Violations FOLLOW UP TO NOV The well has identification and is in compliance.
1065455826 2017-07-27 Production Wells Violations Noted Inspection of this well revealed a pumping unit, tubing, rods and an electric motor. As I neared the well I could hear and smell a significant gas leak. The leak originated from a plastic flow line. This leak will need to be properly repaired. The well also had no identification posted at the wellhead. Identification will need to be posted at the wellhead. There is also a streak of oily substances on the vegetation in line with the flow line. The oily substances on the vegetation will need to be removed and disposed in a proper manner. Feel free to call inspector Matthew Fulk at 740-328-7052 for questions and to update me on the progress of the repairs.
1554700961 2018-04-25 Production Wells No Violations There is still oily substances inside the dike. The dike remains cut where fluids can escape the dike. The brine scald below the dike has not been remediated. The area at the wellhead, where the well has been blown down is still covered with oily substances and has not been remediated.
1812086359 2020-6-25 0:00: PW No Violations 0.10
1817803939 2020-4-10 0:00: PW No Violations 0.20
1823869102 2017-08-22 Production Wells No Violations I called the domestic owner who explained she never received anything in the mail. She then was kind enough to explain they are identified on the States website. I explained that there needs to be a sign or the information needs written or painted on the equipment. She said she didnt realize that and would need a week or two. I asked her to call me when they were identified she said that she would give me a call.
1984637949 2018-04-12 Production Wells Violations Noted There is a large area by that wellhead that is covered with oily residue. It would appear that the well was blown down and the oily substances covered the vegetation in a line perpendicular to the wellhead. The tank battery is across the road on top of the hill. The dike has been breached on the side facing the road. The tank is covered in oil and it has ran down the side of the tank and on top of the water that is in the dike. There was some kind of a small release at this location over the winter. I stopped and spoke with the landowners son who said the mess at the wellhead will be cleaned and he will get the contamination cleaned at the tank battery and fix the breach in the dike.
2118255889 2018-05-29 Production Wells No Violations Violations are resolved and compliance notice is closed out.
37432173 2018-5-4 0:00:0 PW No Violations 0.30
380569542 2017-9-7 0:00:0 PW No Violations 0.50
589766476 2020-6-25 0:00: PW No Violations 0.10
73981558 2004-3-10 0:00: PW No Violations
754786969 2020-7-2 0:00:0 PW No Violations 1.30

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0073981558 US-OH-128412 2004-03-15 Failure to legibly identify well
1065455826 US-OH-101317 2017-10-03 9-1-07 Well operation causing pollution and contamination
1065455826 US-OH-101318 2017-10-03 9-9-05(A)10 Failure to legibly identify well
1065455826 US-OH-101319 2017-10-03 9-9-05(A)8 Equipment pressure rated below operating pressure
1984637949 US-OH-120079 2018-05-31 9-1-07 Well operation causing pollution and contamination
1984637949 US-OH-120080 2018-05-31 9-9-02 General Safety
1984637949 US-OH-120081 2018-05-31 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]