Well Details

Well ID: 34-009-22305
Loading map...
Country: United States
State: Ohio
County: Athens
Municipality: Ames Township
Operator Name: ALTIER BROTHERS INC
Well Pad ID:
Farm/Lease Name: WAGNER T & S & A & F
License Status: Producing
License Date: 1987-10-19
Spud Date: 1981-06-30
Spud Drilling Contractor:
Final Drill Date: 1981-07-02
Well Total Depth: 1532.00 ft
Configuration: Vertical
Latitude: 39.380000
Longitude: -81.990000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-06-22 1429 ALTIER BROTHERS INC GeoDate 6/22/81
Original Spud 1981-06-30
Completed 1981-07-02
Reached Total Depth 1981-07-02
CO 1987-10-19 1429 ALTIER BROTHERS INC GeoDate 10/19/87
COMBINATION WELL 1987-10-19 Issued Date 10/19/87 Expired Date 10/18/88 Proposed Purpose OG Was Plug Supervised Who Superivsed Plug and Abandon Date 10/26/87
Construction Permit Expires 1988-10-18
Record Last Modified 2015-11-20

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1397 1415 17
1397 1415 17
1397 1415 17

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 57000 Gal 55000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GLACIER ENERGY CORP 568.00 80.00 365
1985 GLACIER ENERGY CORP 887.00 144.00 0
2008 ALTIER BROTHERS INC 0.00 0.00 0
2009 ALTIER BROTHERS INC 0.00 0.00 0
2010 ALTIER BROTHERS INC 0.00 0.00 365
2011 ALTIER BROTHERS INC 0.00 0.00 0
2012 ALTIER BROTHERS INC 0.00 131.00 24
2013 ALTIER BROTHERS INC 914.00 251.00 104
2014 ALTIER BROTHERS INC 260.00 0.00 104
2015 ALTIER BROTHERS INC 557.00 117.00 104
2016 ALTIER BROTHERS INC 271.00 0.00 104
2017 ALTIER BROTHERS INC 632.00 45.00 365
2018 ALTIER BROTHERS INC 681.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GLACIER ENERGY CORP Brine 0 365
1985 GLACIER ENERGY CORP Brine 0 0
2008 ALTIER BROTHERS INC Brine 0 0
2009 ALTIER BROTHERS INC Brine 0 0
2010 ALTIER BROTHERS INC Brine 0 365
2011 ALTIER BROTHERS INC Brine 0 0
2012 ALTIER BROTHERS INC Brine 0 24
2013 ALTIER BROTHERS INC Brine 110 104
2014 ALTIER BROTHERS INC Brine 70 104
2015 ALTIER BROTHERS INC Brine 245 104
2016 ALTIER BROTHERS INC Brine 175 104
2017 ALTIER BROTHERS INC Brine 70 365
2018 ALTIER BROTHERS INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1104509771 2016-6-6 0:00:0 PW No Violations 1.20
-1313625315 2015-12-9 0:00: PW No Violations 1.50
001269i870 2002-03-14 Production Wells Violations Noted An inspection of the well revealed No ID at the well or tank battery, oily soil around the well from 55 gal drums, and oily soil around production tanks. NEED FULL ID AT THE WELL AND TANK BATTERY, NEED TO REMOVE ALL OILY SOIL AROUND WELL AND PRODUCTION TANKS, REMOVE THE 55 GAL DRUMS WHICH ARE FULL AND RUNNING OVER.
0046498181 2015-11-17 Production Wells No Violations Follow up to 1447779860. The contaminated materials have not been removed from the dike. The small leak in the line seems to have been repaired. Instead of removing the fluids and contaminated materials the dike seems to have been filed with 1/4-1/2 ton of prepared plugging clay. The scalded area outside of the dike has not been addressed yet.
0083096018 2016-05-13 Production Wells No Violations Would like to see a little more vegetation in the area that was not excavatd.
01269i1062 2002-05-20 Production Wells No Violations Follow-up on NOV, In-Compliance.
0251022070 2015-12-16 Production Wells No Violations Follow up to 1447779860. Fluid in dike and scalded area around side of dike has not been remediated. I called Benny Alteir to arrange a meeting to discuss remediation.
0738539712 2015-12-03 Production Wells No Violations Follow up to 1447779860. Dike or contaminated soils have not been cleaned. Field test samples were taken for the presence of CaCl- in the soil and in the fluids in the dike, samples ranged from 171ppm to 1082ppm based on location of sample. I spoke with Benny Alteir about remediating site.
0864611619 2015-11-27 Production Wells No Violations Follow up to 1447779860. Dike or contaminated soils have not been cleaned.
1102368733 2015-12-07 Production Wells No Violations Follow up to 1447779860. Dike or contaminated soils have not been cleaned.
1104509771 2016-06-06 Production Wells No Violations FOLLOW UP TO NOV # 1447779860. Vegetation is growing back in the area that stays wet. The NOV will be cleared.
1269i1062 2002-5-20 0:00: PW No Violations
1269i870 2002-3-14 0:00: PW No Violations
1290061763 2015-12-24 Production Wells No Violations Follow up to 1447779860. There is fluid in the dike.
1313625315 2015-12-09 Production Wells No Violations Follow up to 1447779860. Fluid in dike and scalded area arout side of dike has not been remediated. It does not appear any of the contamination has been removed from the site.
1447779860 2015-11-12 Production Wells Violations Noted Well is in production and equipped with a pumping unit. Tank battery is two 100 bbl steel tanks, a separator, a water knock-out, and a dike. The dike was full of fluids and oil. There was a small leak in the line running from the separator to the tanks. Fluids had flowed over the dike in the past and resulted in scalding of an area roughly 5 x 15 feet. The identification on the well was not legible. Contaminated fluids and soils shall be removed from the site. And affected areas shall be reseeded and mulched in order to establish vegetative cover. Dike shall be constructed in order to meet SPCC standards. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. If multiple wells are being produced into the common tank each well-head shall be identified as to owner, permit number where available, well number and lease name.
1448044694 2015-11-20 Production Wells No Violations Follow up to 1447779860. double check GPS coordinates inorder to correct RBDMS status.
1450469353 2015-12-18 Production Wells No Violations Follow up to 1447779860. fluid in dike.
1452085554 2016-01-04 Production Wells No Violations Follow up to 1447779860. fluids have been removed from the dike and vegetative cover is reestablishing itself on the impacted area and the dike. There remains a small area of scalded soil outside of the dike but the area has been treated with limeinstead of removing the soil. I will return to the scalded area to check Chloride content in the near future.
1494161945 2016-01-13 Production Wells No Violations Follow up to 1447779860. There is a small area outside of the dike that is still being remediated using lime.
1874075582 2016-01-21 Production Wells No Violations Review of well with Matt Fulk.
1968113657 2015-11-12 Production Wells Violations Noted FOLLOW UP TO NOV # 1447779860 Well is in production and equipped with a pumping unit. Tank battery is two 100 bbl steel tanks, a separator, a water knock-out, and a dike. The dike was full of fluids and oil. There was a small leak in the line running from the separator to the tanks. Fluids had flowed over the dike in the past and resulted in scalding of an area roughly 5 x 15 feet. The identification on the well was not legible. Contaminated fluids and soils shall be removed from the site. And affected areas shall be reseeded and mulched in order to establish vegetative cover. Dike shall be constructed in order to meet SPCC standards. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. If multiple wells are being produced into the common tank each well-head shall be identified as to owner, permit number where available, well number and lease name.
2036897157 2015-12-17 Production Wells No Violations Follow up to 1447779860. I met with the producer at the dike to discuss remediations that have taken place and those that still need to be completed. Two truck loads of soil have been removed from inside the dike and the walls have been reconstructed. The fluids need to be removed from the dike again and the area outside of the dike needs to be remediated.
2070627910 2002-03-14 Production Wells Violations Noted FOLLOW UP TO NOV # 1269i870 An inspection of the well revealed No ID at the well or tank battery, oily soil around the well from 55 gal drums, and oily soil around production tanks. NEED FULL ID AT THE WELL AND TANK BATTERY, NEED TO REMOVE ALL OILY SOIL AROUND WELL AND PRODUCTION T
251022070 2015-12-16 0:00 PW No Violations 1.00
46498181 2015-11-17 0:00 PW No Violations 1.70
738539712 2015-12-3 0:00: PW No Violations 1.00
83096018 2016-5-13 0:00: PW No Violations 1.40
864611619 2015-11-27 0:00 PW No Violations 1.70

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
001269i870 US-OH-107496 2002-03-15 Well operation causing pollution and contamination
001269i870 US-OH-107497 2002-03-15 Failure to legibly identify well
1447779860 US-OH-113004 2015-11-18 Well operation causing pollution and contamination
1447779860 US-OH-113005 2015-11-18 Well insufficiently equipped to prevent escape of oil and gas
1447779860 US-OH-113006 2015-11-18 Failure to legibly identify well
1447779860 US-OH-113007 2015-11-18 No SPCC dike/or failure to keep dike free of water or oil
1968113657 US-OH-119857 2019-01-25 9-1-07 Well operation causing pollution and contamination
2070627910 US-OH-121122 2002-03-15 Well operation causing pollution and contamination
2070627910 US-OH-121123 2002-03-15 Failure to legibly identify well