If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-009-22402 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.39,"lon":-81.94,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Athens | |
Municipality: Bern Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: DEPUE | |
License Status: Active Injection | |
License Date: 1987-06-12 | |
Spud Date: 1981-10-07 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1981-10-11 | |
Well Total Depth: 1650.00 ft | |
Configuration: Vertical | |
Latitude: 39.390000 | |
Longitude: -81.940000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-09-23 | 3969 KAPLAN INTERESTS INC GeoDate 9/23/81 |
Original Spud | 1981-10-07 | |
Completed | 1981-10-11 | |
Reached Total Depth | 1981-10-11 | |
First Injection | 1981-10-31 | |
CO | 1987-06-12 | 3969 KAPLAN INTERESTS INC GeoDate 6/12/87 |
Enhanced Recovery | 1987-06-12 | Issued Date 6/12/87 Expired Date 6/11/88 Acres 0056000 Tool Type RTAF Proposed Formation BEDFORD Proposed Depth 00000 Proposed Drill Depth 00000 |
Completion Report Received | 1987-07-16 | |
Construction Permit Expires | 1988-06-11 | |
Annulus Pressure Monitoring Approved | 1990-08-27 | |
Last Compliance Report | 2000-01-20 | |
Change of Owner | 2004-07-08 | Operator changed from 3969, KAPLAN INTERESTS INC to 7671, KEITO GAS INC |
Change of Owner | 2016-11-03 | Operator changed from 7671, KEITO GAS INC to 9651, AM-TEK OIL INC |
Record Last Modified | 2016-11-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-23 | 0 | 0 | 1 |
2000-05-23 | 1508 | 1532 | 1 |
1508 | 1532 | 1 | |
0 | 0 | 1 | |
0 | 0 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | 1 GAL OF MUSOL AND 250 GAL OF 15% FE ACID. FOR ERP | |||
H2O | 0 | 1450 Bbl | 90000 | |||
H2O | 0 | 0 | 0 | FRAC JOB WITH 1450 BBLS OF GELLED H2O, 90,000# OF 20/40 SAND, AND 500 GAL OF 15% HCL. FOR PRODUCTION |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TRIPLE GAS CO | 201.00 | 489.00 | 0 |
1991 | KAPLAN INTERESTS INC | 13.00 | 0.00 | 210 |
1992 | KAPLAN INTERESTS INC | 118.00 | 0.00 | 365 |
1993 | KAPLAN INTERESTS INC | 9.00 | 0.00 | 365 |
1994 | KAPLAN INTERESTS INC | 17.00 | 0.00 | 365 |
1995 | KAPLAN INTERESTS INC | 113.00 | 0.00 | 365 |
1996 | KAPLAN INTERESTS INC | 37.00 | 0.00 | 365 |
1997 | KAPLAN INTERESTS INC | 87.00 | 0.00 | 365 |
1998 | KAPLAN INTERESTS INC | 60.00 | 0.00 | 365 |
1999 | KAPLAN INTERESTS INC | 27.00 | 28.00 | 365 |
2000 | KAPLAN INTERESTS INC | 26.00 | 0.00 | 365 |
2001 | KAPLAN INTERESTS INC | 1.00 | 0.00 | 365 |
2002 | KAPLAN INTERESTS INC | 1.00 | 0.00 | 365 |
2003 | KAPLAN INTERESTS INC | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TRIPLE GAS CO | Brine | 0 | 0 |
1991 | KAPLAN INTERESTS INC | Brine | 0 | 210 |
1992 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1993 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1994 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1995 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1996 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1997 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1998 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
1999 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
2000 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
2001 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
2002 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
2003 | KAPLAN INTERESTS INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1010081204 | 2018-5-4 0:00:0 | ER | No Violations | |
-1023617377 | 2004-7-15 0:00: | ER | No Violations | |
-1049584662 | 2010-11-17 0:00 | SW | No Violations | 1.00 |
-1054110566 | 2005-6-7 0:00:0 | ER | No Violations | |
-1110184747 | 2008-4-23 0:00: | ER | No Violations | |
-114700666 | 2014-3-27 0:00: | AD | No Violations | 1.30 |
-1204183838 | 2018-9-6 0:00:0 | ER | No Violations | 3.50 |
-120463237 | 2003-11-4 0:00: | SW | No Violations | |
-1205926012 | 2016-11-16 0:00 | ER | No Violations | 3.00 |
-1219800079 | 2014-11-10 0:00 | SW | No Violations | 1.30 |
-1258762872 | 2003-9-18 0:00: | SW | No Violations | |
-133074726 | 2008-1-16 0:00: | ER | No Violations | |
-1367566325 | 2015-12-1 0:00: | SW | No Violations | 0.50 |
-1395316718 | 2018-5-30 0:00: | ER | No Violations | 2.50 |
-1409652914 | 2014-3-27 0:00: | SW | No Violations | 1.50 |
-1426270019 | 2006-1-25 0:00: | SW | No Violations | |
-1492694060 | 2003-5-14 0:00: | ER | No Violations | |
-1503429399 | 2015-12-16 0:00 | SW | No Violations | 1.00 |
-1524639123 | 2005-6-23 0:00: | ER | No Violations | |
-1533280949 | 2020-6-23 0:00: | ER | No Violations | 3.70 |
-1549308562 | 2004-5-4 0:00:0 | SW | No Violations | |
-1561425289 | 2013-12-16 0:00 | SW | No Violations | 1.00 |
-164636067 | 2017-5-31 0:00: | ER | No Violations | 1.50 |
-167130887 | 2015-9-17 0:00: | SW | No Violations | 1.20 |
-1708761242 | 2019-4-29 0:00: | ER | No Violations | |
-1747947312 | 2012-1-5 0:00:0 | ER | No Violations | 1.00 |
-1770990830 | 2010-4-7 0:00:0 | SW | No Violations | 1.50 |
-18318273 | 2005-5-10 0:00: | ER | No Violations | |
-1855947121 | 2017-12-4 0:00: | SW | No Violations | 1.50 |
-1928833385 | 2020-3-18 0:00: | ER | No Violations | 5.50 |
-1939157470 | 2006-10-19 0:00 | ER | No Violations | |
-1983853626 | 2014-5-28 0:00: | SW | No Violations | 0.20 |
-1991506892 | 2001-4-26 0:00: | ER | No Violations | |
-1997237101 | 2018-11-5 0:00: | ER | No Violations | 4.00 |
-2026351385 | 2015-5-4 0:00:0 | SW | No Violations | 1.30 |
-2042822319 | 2012-9-24 0:00: | SW | No Violations | 1.30 |
-208406872 | 2018-3-5 0:00:0 | PW | No Violations | |
-2124137572 | 2003-3-17 0:00: | ER | No Violations | |
-281917211 | 2008-6-24 0:00: | ER | No Violations | |
-406142456 | 2015-9-14 0:00: | ER | No Violations | 1.00 |
-41835207 | 2018-3-26 0:00: | SW | No Violations | 1.50 |
-476160014 | 2018-3-2 0:00:0 | SW | No Violations | 3.00 |
-515955193 | 2011-11-29 0:00 | ER | No Violations | |
-52474478 | 2006-3-28 0:00: | ER | No Violations | |
-562448920 | 2018-5-30 0:00: | SW | No Violations | 0.20 |
-64480502 | 2014-5-19 0:00: | SW | No Violations | 1.80 |
-669614083 | 2007-7-17 0:00: | ER | No Violations | |
-67074341 | 2015-3-16 0:00: | SW | No Violations | 1.00 |
-68068640 | 2019-2-4 0:00:0 | ER | No Violations | 5.40 |
-687188118 | 2012-1-5 0:00:0 | AM | No Violations | 0.30 |
-698177758 | 2010-8-20 0:00: | SW | No Violations | 3.00 |
-77493021 | 2018-5-30 0:00: | SW | No Violations | 5.50 |
-801269235 | 2013-12-31 0:00 | SW | No Violations | 1.80 |
-828840729 | 2008-9-10 0:00: | ER | No Violations | |
-943486398 | 2018-8-14 0:00: | ER | No Violations | |
-957117533 | 2003-2-6 0:00:0 | ER | No Violations | |
-988757395 | 2012-10-23 0:00 | ER | No Violations | 3.50 |
001269i111 | 2000-10-26 | Enhanced Recovery Project | No Violations | No violations at this time. |
001269i168 | 2000-12-07 | Enhanced Recovery Project | No Violations | No violation at this time . Well is on vac. |
001269i859 | 2002-03-07 | Enhanced Recovery Project | No Violations | No violations. Well is on vac. , talked to pumper, company is planning on testing well next Thursday, 14, at 10:00am. |
001269i869 | 2002-03-14 | Enhanced Recovery Project | No Violations | Done a M.I.T. test on this well, well passed test with no problems. |
001269i996 | 2002-04-23 | Enhanced Recovery Project | No Violations | No violations at this time, no pressure on annulus side of well. |
0018318273 | 2005-05-10 | Enhanced Recovery Project | Violations Noted | The pressures were measured while the pump was operating. The discharge hose on the sump pump was laying on the ground outside the dike. Oil was pooling outside the dike, at the discharge hose. |
0041835207 | 2018-03-26 | Salt Water Injection Well | No Violations | The salt water injection well had 22 psi on the annulus and 0 psi on the injection tubing. The dike had approximately 4 inches of water in it. Legible identification was posted. I contacted well owner Mr. Andrew Ulrich at 11:30 AM to have him pump out the dike |
0052474478 | 2006-03-28 | Enhanced Recovery Project | No Violations | There were no violations. |
005609i171 | 2001-04-26 | Enhanced Recovery Project | Violations Noted | An inspection of the well revealed that the 1/4 valve on the injection needs replaced at the well along with placing a 1/4 valve on the annulus side of well for inspections. A mini test should be done on this well within the next couple of months. |
0064480502 | 2014-05-19 | Salt Water Injection Well | No Violations | No noted violations. |
0067074341 | 2015-03-16 | Salt Water Injection Well | No Violations | No noted violations. The sump pump at the facility was not operational at the time of inspection and there was roughly a foot of water on the floor of the facility. |
0068068640 | 2019-02-04 | Enhanced Recovery Project | No Violations | Compliance Notice # 833534965 follow up inspection. Inspected the containment area, unloading pad, tanks, injection pressure and annulus pressure. The containment is frozen with 4 inches of ice . The injection tubing master valve is closed. The injection line has not been repaired or replaced. The containment sump pump 1 inch black plastic line is not connected to the tank, it is extended out of the containment. There was no evidence of discharge of fluids outside of containment. Am-Tek was notified to connect the 1 inch plastic sump line to the tank. |
0077493021 | 2018-05-30 | Salt Water Injection Well | No Violations | I received a call from inspector Matt Fulk. Matt found a brine kill caused by a flow that runs from the tanks to the well. The kill area was approximately 20 feet by 30 feet. I tested the soil for chlorides and found the highest reading to be 400 PPM. Approximately 4 inch of soil was removed and placed in a line pit. This material will be hauled out and properly disposed of. The leak in the flow line was located. AM-TEK oil has the well shut down until they decide how to repair the leak in the flow line. |
0077866224 | 2005-01-19 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0103264166 | 2017-08-16 | Enhanced Recovery Project | No Violations | I inspected the unloading pad, containment dike and the pump. The pump was not in operation during my inspection. The unloading pad and dike were free of fluids. |
0105517496 | 2011-12-12 | Enhanced Recovery Project | Violations Noted | Dike had ice in it and pump house had roughly 1 foot of ice in it. Sump pump was not running and line from sump was no longer connected to injection tank. Injection at well head had 40 psi and annulus had zero psi on it. A mechanical integrity test must be performed. |
0114700666 | 2014-03-27 | Annular Disposal | No Violations | I accompanied inspector Josh Garland to injection well for an inspection. The annular tested at 318psi and the injection tubing was on vacuum. |
0120463237 | 2003-11-04 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
01269i1096 | 2002-06-03 | Enhanced Recovery Project | No Violations | No violations. |
01269i1415 | 2002-10-01 | Preliminary Restoration | No Violations | No violations at this time. |
0133074726 | 2008-01-16 | Enhanced Recovery Project | No Violations | No violations were found, at the time of inspection. |
0143540858 | 2013-04-02 | Salt Water Injection Well | No Violations | Follow up to inspection #188518550 issued by Dan Goins. The well is in compliance. |
0144744586 | 2008-02-29 | Enhanced Recovery Project | No Violations | There were no violations at the time. |
0147801776 | 2011-08-16 | Enhanced Recovery Project | Violations Noted | An inspection of the well revealed no ID at the well or storage tanks. Fittings leaking on pump and dike has approx. 1 ft of water standing. Need full and legible ID at both the well head and storage tanks. Repair or replace leaking fittings on pump in building, pump out all water in dike area and building. |
0164636067 | 2017-05-31 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment area, tanks, injection pump, injection pressure and annulus pressure. Containment area was free of fluids. |
0167130887 | 2015-09-17 | Salt Water Injection Well | No Violations | Follow up to -406142456. A mini MIT was performed using fresh water. The annulus was pressurized to 440 psi and no pressure was lost over the 15 minute testinf period. |
0181112288 | 2009-03-12 | Enhanced Recovery Project | No Violations | No violations were found, at the time of inspection. |
0188518550 | 2011-08-16 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 147801776 An inspection of the well revealed no ID at the well or storage tanks. Fittings leaking on pump and dike has approx. 1 ft of water standing. Need full and legible ID at both the well head and storage tanks. Repair or replace leaking fittings on pump in building, pump out all water in dike area and building. |
0208406872 | 2018-03-05 | Production Wells | No Violations | The sump pump to pump fresh water from inside the dike has been fixed. This violation is resolved. |
0221989747 | 2013-04-02 | Salt Water Injection Well | No Violations | No violations at the unloading facility or at the well head. |
0281917211 | 2008-06-24 | Enhanced Recovery Project | No Violations | No violations were found. |
0290727867 | 2006-06-06 | Enhanced Recovery Project | Violations Noted | |
0362119895 | 2006-07-14 | Enhanced Recovery Project | No Violations | The tank was patched and no longer leaking. |
0406142456 | 2015-09-14 | Enhanced Recovery Project | Violations Noted | No noted violations at surface facility. The annulus at the well had zero pressure and the injection line was on a vacuum. The well shall be shut in until a MIT test is performed and passed. I notified Keith North of Keito Gas Inc of the violation. |
0419543714 | 2004-02-11 | Enhanced Recovery Project | No Violations | No violations at the time of inspection. |
0476160014 | 2018-03-02 | Salt Water Injection Well | No Violations | I met with the owner of the well, Mr. Andrew Ulrich. Mr. Ulrich has replaced the sump pump and the injection pump. He was pumping the dike out into 2-210 barrel tanks during my inspection. The water in the tanks is then pumped up to the injection well. The dike and pump house are not free of water but the level is coming down. I will recheck first of next week to see if the dike is free of water. |
0511937160 | 2017-03-09 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment area, tanks, injection pump, injection pressure and annulus pressure. Containment area was free of fluids. The pump was on and fluid was going down the well while I was there for my inspection. I opened the valve to their gauge and it showed 115 psi. |
0515955193 | 2011-11-29 | Enhanced Recovery Project | No Violations | Met Inspector Josh Garland at tank dike. Brine pump line inside pump house leaking brine. Dike sump pump discharging water outside of dike. Talked to pumper and he fixed the leak and will change sump discharge line to pump into steel tank. Accompanied by Andy Thomas MRI 1. |
0546293537 | 2018-06-14 | Salt Water Injection Well | No Violations | Inspection of the line that leaked found the ditch to still be open and the old line still in the hole. The injection line has not been repaired yet. The contaminated soil is still in a lined and covered pit by the injection well. Andrew Ulrich owner of the company said the line will be fixed with 1.5 steel line as soon as they pull some out of a well. He plans on having it completed by the middle of August. |
0562448920 | 2018-05-30 | Salt Water Injection Well | No Violations | Inspected the injection well, unloading pad and the pump house. The unloading pad had some standing water. AM-TEX was running a sump pump during my inspection to remove the water. The water was being pumped into a 210 barrel tank. |
0669614083 | 2007-07-17 | Enhanced Recovery Project | No Violations | There were no violations at the time. |
0687188118 | 2012-01-05 | Administrative Inspection | No Violations | I spoke with Keith North about bringing well into compliance and about possible long term solutions to the water problem associated with the tank battery dike. |
0698177758 | 2010-08-20 | Salt Water Injection Well | No Violations | Performed integrity test: Pump had been running for over an hour and tubing still showing a vaccuum, annulus pressured up to 230# and held for 15 min. - - no decrease. Facility looks clean, no problems noted. |
0742957241 | 2012-06-15 | Salt Water Injection Well | No Violations | No violations. Injection on vacuum. |
0796439216 | 2016-09-01 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment area, tanks, injection pump, injection pressure and annulus pressure. |
0801269235 | 2013-12-31 | Salt Water Injection Well | No Violations | Nipple and ball valve removed from the well head and grease removed from inside of well head. Bull plugs were installed and the annulus was pressurized to 330 psi and a mini Mechanical Integrity Test was administered. No pressure was lost during the 15 minute test period. |
0828840729 | 2008-09-10 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
0833534965 | 2018-05-29 | Enhanced Recovery Project | Violations Noted | Walking from one production well to another, I happened upon a large brine scald that was in the path of the injection flowline up the hill toward the well. There was some oily substances on top of the ground. The scalded area was approximately 25 x 40. I notified the Andrew Ulrich who sent the pumper to meet me at the tank battery facility. I showed the pumper where the scald was and talked about the course of action to remediate the location. Buddy the pumper stated he would bring his small 4 wheel drive Kubota tractor with a bucket and hoe attachment to remove the affected soil. |
0854722960 | 2007-02-21 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
0874108101 | 2011-12-14 | Enhanced Recovery Project | No Violations | Demonstrated mechanical integrity. |
0943486398 | 2018-08-14 | Enhanced Recovery Project | No Violations | I spoke with Andrew Ulrich about the progress of this job and he said that he is still waiting to get a well pulled with 1.5 inch tubing in it to replace the failed 1.5 inch pipe going to the recovery well. Inspection of the location revealed the hole is still excavated and no further affected areas were detected. |
0957117533 | 2003-02-06 | Enhanced Recovery Project | No Violations | No vioaltions at this time. |
0970780550 | 2009-05-06 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
0988757395 | 2012-10-23 | Enhanced Recovery Project | No Violations | Dike is free of water. Unloading pad cracks have been filled. Good identification at the surface facility and the wellhead. |
1010081204 | 2018-05-04 | Enhanced Recovery Project | Violations Noted | Our records indicate that the Division has not received the 2017 Enhanced Recovery Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Reports received 6/8/2018 |
1023617377 | 2004-07-15 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
1028808642 | 2004-10-08 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
103264166 | 2017-8-16 0:00: | ER | No Violations | 3.50 |
1049584662 | 2010-11-17 | Salt Water Injection Well | No Violations | Inspection this day found well idle, pump not running, pump house floods with a lot of rain and this day fresh water laying in floor of house. Good IDs, well on vaccuum. |
1054110566 | 2005-06-07 | Enhanced Recovery Project | No Violations | FOLLOW UP ON NOV. The well is in compliance.
The oil was cleaned up. |
105517496 | 2011-12-12 0:00 | ER | No Violations | 1.00 |
1063936072 | 2019-6-7 0:00:0 | ER | No Violations | 3.00 |
1079616075 | 2004-03-18 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1110184747 | 2008-04-23 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
1115812122 | 2011-12-14 | Enhanced Recovery Project | No Violations | Accompanied by Josh Garland MRI. Witnessed pumper pressure up the annulus to 70 psi. Monitored annulus pressure for 15 minutes no loss in pressure. A 2 ball valve on annulus was leaking through packing nut. Packing nut was tightened and leak was corrected. Pumper plans to replace ball valves on annulus soon. |
1174775604 | 2011-12-07 | Enhanced Recovery Project | Violations Noted | Waterline from sump pump is feeding into injection tank. Pump is functioning correctly and not leaking. Pump house and dike are full of roughly one foot of water again. Spoke with pumper and he let me know the sump pump only gets turned on for a short time in the mornings. |
1195252640 | 2013-07-15 | Salt Water Injection Well | No Violations | The injection line inside the pump house was leaking at a 90 degree elbow. All wells shall have equipment rated to withstand operating pressures. Leaking line/elbow shall be repaired or replaced. |
1204183838 | 2018-09-06 | Enhanced Recovery Project | No Violations | Compliance notice # 833534965 follow up inspection. The injection line has not been replaced and tested. The injection tubing master valve is closed. 54 feet east of the well is a pile of contaminated material that is covered with a plastic tarp. |
1205926012 | 2016-11-16 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment area, tanks, injection pump, injection pressure and annulus pressure. Containment area was free of fluids. |
1215311282 | 2007-09-10 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
1219800079 | 2014-11-10 | Salt Water Injection Well | No Violations | No noted violations at well or facility. The pump was not on durring my inspection. |
1258762872 | 2003-09-18 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1268909782 | 2005-06-09 | Enhanced Recovery Project | No Violations | FOLLOW UP ON NOV. The well is in compliance. |
1269i1096 | 2002-6-3 0:00:0 | ER | No Violations | |
1269i111 | 2000-10-26 0:00 | ER | No Violations | |
1269i1415 | 2002-10-1 0:00: | PL | No Violations | |
1269i168 | 2000-12-7 0:00: | ER | No Violations | |
1269i859 | 2002-3-7 0:00:0 | ER | No Violations | |
1269i869 | 2002-3-14 0:00: | ER | No Violations | |
1269i996 | 2002-4-23 0:00: | ER | No Violations | |
1292495877 | 2006-12-18 | Enhanced Recovery Project | No Violations | No violations were found at the time of inspection. |
1352740552 | 2008-12-09 | Enhanced Recovery Project | No Violations | No violations were found. Pressures taken while the pump was operating. |
1357322818 | 2013-01-04 | Salt Water Injection Well | No Violations | The dike was in good shape as well as the unloading pad. The injection at the well head was 60 psi and the annuls was on zero. The pumper for the company was at the pump house, so injection was halted and a mini Mechanical Integrity test was administered immediately. The well held the required pressure for the test period. The test was passed and injection was allowed to continue. After the test the injection tubing pressure was checked again and was 35 psi. |
1361292642 | 2019-11-20 0:00 | ER | No Violations | 2.80 |
1367566325 | 2015-12-01 | Salt Water Injection Well | No Violations | Facility inspection. The dike contained fluids but the operator was in the process of draining the dike and repairing the sump pump during my inspection. |
1374235330 | 2013-07-19 | Salt Water Injection Well | No Violations | Follow up to 1195252640. The leaking line inside the pump house has been repaired. |
1395316718 | 2018-05-30 | Enhanced Recovery Project | No Violations | I went to the location to show Inspector Kip Thompson where the scald was. I returned about 2 hours later to see how the clean up was progressing. I watched and trained with Inspector Kip Thompson taking soil samples and mixing water with it to test the level of chlorides present. I also witnessed the excavation of the line that was leaking. |
1409652914 | 2014-03-27 | Salt Water Injection Well | No Violations | No noted violations. |
1426270019 | 2006-01-25 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1429586380 | 2016-06-14 | Enhanced Recovery Project | No Violations | Inspected the unloading pad, containment area, tanks, injection pump, injection pressure and annulus pressure. Identification posted. |
143540858 | 2013-4-2 0:00:0 | SW | No Violations | 0.50 |
144744586 | 2008-2-29 0:00: | ER | No Violations | |
1465563142 | 2012-02-03 | Enhanced Recovery Project | No Violations | Met Josh Garland at site, reviewed Compliance Notice Josh had wrote to company, follow-up on Compliance Notice, In-Compliance. |
147801776 | 2011-8-16 0:00: | ER | No Violations | |
1492694060 | 2003-05-14 | Enhanced Recovery Project | No Violations | No violations. |
1503429399 | 2015-12-16 | Salt Water Injection Well | No Violations | No noted violations at well or facility. Pump was not running during time of inspection. |
1524639123 | 2005-06-23 | Enhanced Recovery Project | No Violations | Lease road needs work. |
1549308562 | 2004-05-04 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1561425289 | 2013-12-16 | Salt Water Injection Well | No Violations | Ice and water in dike at pump facility. Sump pump not running at time of inspection. Water in dike field tested and found to have no Chloride content. Injection tubing at well was on vacuum, however I was unable to accurately test the annular pressure. Upon opening the 3/4 needle valve on the annulus I found grease squirting from the open valve. Mechanical integrity was proven, but immeasurable. I estimated the annular pressure to be around 10 psi for reporting purposes. |
1595920185 | 2014-09-18 | Salt Water Injection Well | No Violations | No noted violations. |
1652487929 | 2012-01-05 | Enhanced Recovery Project | No Violations | Met Josh Garland at well site, dike around storage tanks needs pumped out and crack in unloading pad needs repaired. Josh will notify company of violations. |
1708761242 | 2019-04-29 | Enhanced Recovery Project | Violations Noted | Our records indicate that the Division has not received the Enhanced Recovery Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
1722750630 | 2007-04-12 | Enhanced Recovery Project | No Violations | There were no violations at the time of inspection. |
1734701884 | 2018-02-14 | Salt Water Injection Well | Violations Noted | Inspection of tank battery and unloading pad found the dike and the unloading pad filled with water. I traveled to an area with cell reception and called Andrew Ulrich the owner/operator of the well and explained I would need the dike emptied of water. He explained that the sump pump went out and that he had given a new pump to his well tender and that he would call him and have him get on it right away. I called acting UIC inspector Kip Thompson and explained the situation and let him know of my intentions. |
1747947312 | 2012-01-05 | Enhanced Recovery Project | Violations Noted | The dike and pump house had roughly 1 foot of water in it. The sump pump was not running at the time of inspection. Trees had grown up on and inside dike. Trees shall be removed from dike. The loading area has a crack that allows ground water to seep up through and into the dike. The cracks in the loading area shall be repaired. The dike shall be emptied of all water. The dike shall be kept free and clear of water at all times. |
1770990830 | 2010-04-07 | Salt Water Injection Well | No Violations | Inspection this day found well with pump running. Pump pressure down at facility read 70# and pump had been running less than an hour, pressure up at well still on vacuum, and annulus pressure at 0. Will do 15 min. annulus test next quarter when drier - well up on top of big hill - operator said takes 70# to pump water up the hill, pump only pumps 2 bbl/hr. Floor of pumphouse has skim of oil on it, water has been pumped out but when rains, tends to flood the pumphouse. Told them I would like to see more dike next time they have dozer in, floor cleaner. Good IDs found at pump and well. Road to well rough but still passable. Inspection time includes driving time. |
1810540977 | 2019-02-06 | Enhanced Recovery Project | No Violations | Compliance Notice# 833534965 follow up inspection. Inspected the unload pad, containment dike, tanks, injection pump and containment sump pump. The sump pump 1 inch black plastic line has been placed inside the containment dike. The 1 inch line is not connected to a tank. The injection operations are shut in, due to the injection line needing to be replaced. |
181112288 | 2009-3-12 0:00: | ER | No Violations | |
1855947121 | 2017-12-04 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 22 psi on the annulus and 210 psi on the injection tubing. The containment dike was free of fluids. Legible identification was posted. |
188518550 | 2011-8-16 0:00: | ER | No Violations | |
1911119808 | 2019-8-22 0:00: | ER | No Violations | 4.00 |
1939157470 | 2006-10-19 | Enhanced Recovery Project | No Violations | No violations. |
1981021203 | 2004-06-21 | Enhanced Recovery Project | No Violations | No violations at the time of inspection. |
1983853626 | 2014-05-28 | Salt Water Injection Well | No Violations | Surface facility inspection. No noted violations. |
1991506892 | 2001-04-26 | Enhanced Recovery Project | Violations Noted | FOLLOW UP TO NOV # 5609i171 An inspection of the well revealed that the 1/4 valve on the injection needs replaced at the well along with placing a 1/4 valve on the annulus side of well for inspections. A mini test should be done on this well within the next couple of months. |
1997237101 | 2018-11-05 | Enhanced Recovery Project | No Violations | Inspected the containment dike, tanks, injection pump, injection pressure and annulus pressure. The injection line is shut off. The injection line has not been tested and in not in use. The injection tubing master valve is closed. Identification is posted. |
2026351385 | 2015-05-04 | Salt Water Injection Well | No Violations | No noted violations at facility or well. |
2042822319 | 2012-09-24 | Salt Water Injection Well | No Violations | There were still cracks in the unloading pad. I spoke with Keith North of Keito and granted a week extension to complete the work. The 2 ball valve at the well head was not functioning correctly, but I was still able to take pressure measurements. |
2044930943 | 2013-01-04 | Salt Water Injection Well | No Violations | Follow up to -1797947312. The dike and the off loading pad look good. |
2054112284 | 2016-01-21 | Enhanced Recovery Project | No Violations | No noted violations at facility. |
2072489873 | 2005-10-13 | Enhanced Recovery Project | No Violations | Overall, conditions at the facility and well site were acceptable. |
2124137572 | 2003-03-17 | Enhanced Recovery Project | No Violations | No violations. |
2126409921 | 2011-11-29 | Enhanced Recovery Project | Violations Noted | Pump fitting had corroded and brine was escaping onto pump house floor. Brine was then draining into sump pump and being ejected out of dike. Pump fitting shall be repaired or replaced. Sump pump shall be immediately shutdown and all waters in dike shall be emptied into injection vessel. |
221989747 | 2013-4-2 0:00:0 | SW | No Violations | 0.50 |
290727867 | 2006-6-6 0:00:0 | ER | No Violations | |
362119895 | 2006-7-14 0:00: | ER | No Violations | |
419543714 | 2004-2-11 0:00: | ER | No Violations | |
511937160 | 2017-3-9 0:00:0 | ER | No Violations | 2.00 |
546293537 | 2018-6-14 0:00: | SW | No Violations | 0.30 |
5609i171 | 2001-4-26 0:00: | ER | No Violations | |
742957241 | 2012-6-15 0:00: | SW | No Violations | 0.80 |
77866224 | 2005-1-19 0:00: | SW | No Violations | |
796439216 | 2016-9-1 0:00:0 | ER | No Violations | 1.00 |
833534965 | 2018-5-29 0:00: | ER | No Violations | 2.00 |
854722960 | 2007-2-21 0:00: | ER | No Violations | |
874108101 | 2011-12-14 0:00 | ER | No Violations | 1.00 |
970780550 | 2009-5-6 0:00:0 | ER | No Violations | |
iTOMK00012 | 2001-04-26 | Enhanced Recovery Project | Violations Noted | |
iTOMK000129 | 2001-4-26 0:00: | ER | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0018318273 | US-OH-118288 | 2005-05-11 | Pollution/Contamination | |
005609i171 | US-OH-126205 | 2001-04-26 | Violation of injection tubing/fitting requirements | |
0105517496 | US-OH-100992 | 2012-08-24 | Failure to monitor annulus pressure | |
0147801776 | US-OH-113668 | 2011-08-18 | Insufficient/No identification | |
0147801776 | US-OH-113669 | 2011-08-18 | Equipment pressure rated below operating pressure | |
0147801776 | US-OH-113670 | 2011-08-18 | No SPCC dike/or failure to keep dike free of water or oil | |
0290727867 | US-OH-123016 | 2006-06-21 | Pollution/Contamination | |
0406142456 | US-OH-124317 | 2015-09-24 | Failure to monitor annulus pressure | |
0833534965 | US-OH-129493 | 2018-06-11 | 9-5-06 | Pollution/Contamination |
1010081204 | US-OH-100520 | 2018-08-03 | Failure to file enhanced recovery annual report | |
1174775604 | US-OH-104619 | 2011-12-07 | Failure to keep dike or pit free of brine or other wastes | |
1708761242 | US-OH-116944 | 2019-05-09 | Failure to file enhanced recovery annual report | |
1734701884 | US-OH-117228 | 2018-02-28 | 9-3-05(A)6 | Contamination at surface facility (permit after 6-1-82) |
1747947312 | US-OH-117364 | 2012-09-21 | Pollution/Contamination | |
1747947312 | US-OH-117365 | 2012-09-21 | Contamination at storage facility (permit after 6/1/82) | |
1747947312 | US-OH-117366 | 2012-01-05 | Pits not liquid tight/Improper construction or use | |
1991506892 | US-OH-120206 | Violation of injection tubing/fitting requirements | ||
2126409921 | US-OH-121783 | 2011-12-06 | Pollution/Contamination | |
2126409921 | US-OH-121784 | 2011-12-06 | Equipment pressure rated below operating pressure | |
iTOMK00012 | US-OH-131663 | Violation of injection tubing/fitting requirements |
For data sources see[9]