If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-009-23032 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.36,"lon":-81.97,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Athens | |
Municipality: Canaan Township | |
Operator Name: METCALF JOHN C DBA METCALF DRI | |
Well Pad ID: | |
Farm/Lease Name: BAKER HELEN | |
License Status: Historical Production Well | |
License Date: 1984-03-13 | |
Spud Date: 1984-07-16 | |
Spud Drilling Contractor: BOB WITHEM | |
Final Drill Date: 1984-07-25 | |
Well Total Depth: 315.00 ft | |
Configuration: Vertical | |
Latitude: 39.360000 | |
Longitude: -81.970000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1984-03-13 | Issued Date 3/13/84 Expired Date 9/9/84 Acres 0087000 Tool Type RTF Proposed Formation BUELL RUN Proposed Depth 00315 Proposed Drill Depth 00315 |
Original Spud | 1984-07-16 | UPDATE STATUS PER MATT FULK, CHANGED FORM FR TO HP, WELL EXISTS AND IS BEING OPERATED B YLAMIE METCALF, NEEDS TO REGISTER WELL, UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 05/2/2018. |
Completed | 1984-07-25 | UPDATE STATUS PER MATT FULK, CHANGED FORM FR TO HP, WELL EXISTS AND IS BEING OPERATED B YLAMIE METCALF, NEEDS TO REGISTER WELL, UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 05/2/2018. |
Reached Total Depth | 1984-07-25 | UPDATE STATUS PER MATT FULK, CHANGED FORM FR TO HP, WELL EXISTS AND IS BEING OPERATED B YLAMIE METCALF, NEEDS TO REGISTER WELL, UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 05/2/2018. |
CO | 1984-07-31 | 339 Withem Bob L GeoDate 3/13/84 |
Construction Permit Expires | 1984-09-09 | UPDATE STATUS PER MATT FULK, CHANGED FORM FR TO HP, WELL EXISTS AND IS BEING OPERATED B YLAMIE METCALF, NEEDS TO REGISTER WELL, UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 05/2/2018. |
Completion Report Received | 1984-11-30 | UPDATE STATUS PER MATT FULK, CHANGED FORM FR TO HP, WELL EXISTS AND IS BEING OPERATED B YLAMIE METCALF, NEEDS TO REGISTER WELL, UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 05/2/2018. |
Change of Owner | 1997-06-16 | Operator changed from 339, WITHEM BOB L to 5852, METCALF JOHN & JAMIE |
Change of Owner | 1997-06-17 | Operator changed from 339, WITHEM BOB L to 5852, METCALF JOHN & JAMIE |
Record Last Modified | 2018-05-02 | UPDATE STATUS PER MATT FULK, CHANGED FORM FR TO HP, WELL EXISTS AND IS BEING OPERATED B YLAMIE METCALF, NEEDS TO REGISTER WELL, UPDATE COORDINATES PER DOGRM SURVEYOR-ALE 05/2/2018. |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | NONE |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | METCALF JOHN C DBA METCALF DRI | 0.00 | 0.00 | 0 |
2003 | METCALF JOHN C DBA METCALF DRI | 0.00 | 0.00 | 0 |
2004 | METCALF JOHN C DBA METCALF DRI | 0.00 | 0.00 | 0 |
2005 | METCALF JOHN C DBA METCALF DRI | 0.00 | 0.00 | 0 |
2006 | METCALF JOHN C DBA METCALF DRI | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | METCALF JOHN C DBA METCALF DRI | Brine | 0 | 0 |
2003 | METCALF JOHN C DBA METCALF DRI | Brine | 0 | 0 |
2004 | METCALF JOHN C DBA METCALF DRI | Brine | 0 | 0 |
2005 | METCALF JOHN C DBA METCALF DRI | Brine | 0 | 0 |
2006 | METCALF JOHN C DBA METCALF DRI | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1084689973 | 2020-4-16 0:00: | PW | No Violations | 0.10 |
-435725278 | 2012-12-10 0:00 | PW | No Violations | 0.40 |
-74385186 | 2014-1-15 0:00: | PW | No Violations | 0.10 |
-801727449 | 2010-8-9 0:00:0 | PW | No Violations | 0.50 |
0074385186 | 2014-01-15 | Production Wells | No Violations | Follow up to -435725278. Pumping unit with no power. Line to sales open. |
0435725278 | 2012-12-10 | Production Wells | Violations Noted | The well was not equipped with an identification. The well is equipped with a 5 surface casing and a combination unit that produces out of the 1 tubing. The surface casing was equipped with a makeshift head that the tubing came up through. The pumping unit was equipped with an electric motor and the motor was running at the time of inspection but the arms on the pumping unit were disconnected and was inoperable. The motor was tied off to a tree with tie down ratchet straps. There was contact information at the tank battery but there was no well number. The production tanks were only 2 feet apart. There is a leak at the valve on the load line near the bottom of the production tank inside the dike. The drain of the dike was open and the wall of the dike had been flattened in a places. There was two 55 gallon drums on site as well as production lines not in use. The production lines that were in use were laid on top of the ground. All producing leases shall be legibly identified in a conspicuous place on or near the well-head or the storage tank as to owner, lease name, well number, permit number where available, county, and an emergency telephone number. If multiple wells are being produced into the common tank each well-head shall be identified as to owner, permit number where available, well number and lease name. All oily materials in in dike shall be removed and disposed of properly. Dike drain shall be equipped with a functioning valve or stopper to prevent unintentional draining of contaminated water. Dike wall shall be repaired or rebuilt. Tanks shall be placed a minimum of 3 feet apart. Any production lines that are in an area expected to be under cultivation shall be buried. |
0649111805 | 2013-10-22 | Production Wells | No Violations | Follow up to -435725278. Well equipped with pumping unit with electric motor. |
0801727449 | 2010-08-09 | Production Wells | No Violations | Inspection this day with Mark Hines, new owner, found well with jack, not producing. Says they were calling this #26 and should show as PR. These wells are all mixed up with permit nos. Mark wants to get them correctly identified and producing but problem with legal ownership. Good IDs say Mark is owner, correct phone nos. This permit no plotting closest to well, may not be correct. |
1104343652 | 2014-10-24 | Production Wells | No Violations | Follow up to -435725278. Valves closed. Not in production. |
1438182932 | 2015-07-29 | Production Wells | No Violations | Follow up to -435725278. Well is equipped with a pumping unit with a power source, in production. Identification at tanks, no leak at tanks. |
1519395193 | 2012-12-19 | Production Wells | No Violations | Follow up to -435725278. Reviewed violations at well site with owner. We talked about getting the well into production, putting an ID on the well, and burring production lines that run through the field the land owner wants to place under cultivation. |
1547113354 | 2018-05-08 | Production Wells | No Violations | This well is registered to John Metcalf. The well was originally listed as FR. The status changed because survey said this was the well that lined up with this particular well plat. This well is just a piece of casing sticking out of the ground. |
2027464359 | 2013-03-14 | Production Wells | No Violations | Follow up to -435725278. The pumping unit is a combination unit. The Casing was equipped with a head but no stuffing box. No ID. |
649111805 | 2013-10-22 0:00 | PW | No Violations | 0.10 |
666004227 | 2020-5-7 0:00:0 | PW | No Violations | 0.10 |
iANGE00021 | 1997-06-12 | Final Restoration | No Violations | |
iANGE000215 | 1997-6-12 0:00: | FR | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0435725278 | US-OH-124678 | 2015-08-03 | Failure to legibly identify well | |
0435725278 | US-OH-124679 | 2015-08-03 | Violation of tank spacing requirements | |
0435725278 | US-OH-124680 | 2015-08-03 | Equipment pressure rated below operating pressure | |
0435725278 | US-OH-124681 | 2015-08-03 | No SPCC dike/or failure to keep dike free of water or oil | |
0435725278 | US-OH-124682 | 2015-08-03 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
0435725278 | US-OH-124683 | 2015-08-03 | Statement of annual production not filed |
For data sources see[8]