If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 34-009-23270 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.49,"lon":-82.11,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Athens | |
| Municipality: Trimble Township | |
| Operator Name: LUOIL INC | |
| Well Pad ID: | |
| Farm/Lease Name: SUNDAY CREEK COAL CO | |
| License Status: Producing | |
| License Date: 1995-04-19 | |
| Spud Date: 1985-11-07 | |
| Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
| Final Drill Date: 1985-11-10 | |
| Well Total Depth: 4023.00 ft | |
| Configuration: Vertical | |
| Latitude: 39.490000 | |
| Longitude: -82.110000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| Oil and Gas | 1985-10-18 | Issued Date 10/18/85 Expired Date 10/18/86 Acres 0189000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04023 Proposed Drill Depth 04023 |
| Original Spud | 1985-11-06 | |
| Completed | 1985-11-10 | |
| Reached Total Depth | 1985-11-10 | |
| CO | 1985-12-01 | 133 QUAKER STATE OIL REF CORP GeoDate 10/18/85 |
| Completion Report Received | 1986-02-11 | |
| Construction Permit Expires | 1986-10-18 | |
| Annular Disposal Well | 1995-04-19 | |
| CO | 1995-10-18 | 182 BELDEN & BLAKE CO GeoDate 10/18/85 |
| Revocation | 2000-05-31 | |
| Change of Owner | 2002-08-06 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC |
| Change of Owner | 2015-08-05 | Operator changed from 1966, PETROX, INC to 8373, ROULETTE ENERGY LLC |
| Last Compliance Report | 2017-08-18 | |
| Change of Owner | 2018-11-19 | Operator changed from 8373, ROULETTE ENERGY LLC to 8073, LUOIL INC |
| Record Last Modified | 2018-11-19 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 1998-01-09 | 3869 | 3888 | 1 |
| 3869 | 3888 | 1 | |
| 3869 | 3888 | 1 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| N2 | 0 | 250 Mscf | 0 | |||
| H2O | 0 | 2595 Bbl | 44000 | ALSO USED 250 MCF NITROGEN - AVE. RATE OF 34 BPM |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1985 | QUAKER STATE OIL REF CORP | 6185.00 | 1348.00 | 28 |
| 1986 | QUAKER STATE OIL REF CORP | 6441.00 | 1021.00 | 365 |
| 1987 | QUAKER STATE OIL REF CORP | 4595.00 | 635.00 | 365 |
| 1988 | QUAKER STATE OIL REF CORP | 3088.00 | 478.00 | 365 |
| 1989 | QUAKER STATE OIL REF CORP | 2411.00 | 453.00 | 365 |
| 1990 | QUAKER STATE OIL REF CORP | 2169.00 | 339.00 | 365 |
| 1991 | QUAKER STATE OIL REF CORP | 1392.00 | 228.00 | 365 |
| 1992 | QUAKER STATE OIL REF CORP | 1101.00 | 210.00 | 365 |
| 1993 | QUAKER STATE OIL REF CORP | 1137.00 | 193.00 | 365 |
| 1994 | QUAKER STATE OIL REF CORP | 801.00 | 156.00 | 365 |
| 1995 | BELDEN & BLAKE CORPORATION | 263.00 | 0.00 | 122 |
| 1996 | BELDEN & BLAKE CORPORATION | 620.00 | 450.00 | 340 |
| 1997 | BELDEN & BLAKE CORPORATION | 676.00 | 15.00 | 85 |
| 1998 | BELDEN & BLAKE CORPORATION | 1840.00 | 17.00 | 365 |
| 1999 | BELDEN & BLAKE CORPORATION | 131.00 | 0.00 | 366 |
| 2000 | BELDEN & BLAKE CORPORATION | 36.00 | 0.00 | 366 |
| 2001 | BELDEN & BLAKE CORPORATION | 0.00 | 1.00 | 366 |
| 2002 | PETROX, INC | 245.00 | 171.00 | 85 |
| 2003 | PETROX, INC | 600.00 | 169.00 | 365 |
| 2004 | PETROX, INC | 746.00 | 69.00 | 365 |
| 2005 | PETROX, INC | 988.00 | 135.00 | 365 |
| 2006 | PETROX, INC | 1153.00 | 149.00 | 365 |
| 2007 | PETROX, INC | 1128.00 | 134.00 | 365 |
| 2008 | PETROX, INC | 847.00 | 62.00 | 365 |
| 2009 | PETROX, INC | 859.00 | 143.00 | 365 |
| 2010 | PETROX, INC | 643.00 | 157.00 | 365 |
| 2011 | PETROX, INC | 664.00 | 85.00 | 365 |
| 2012 | PETROX, INC | 518.00 | 66.00 | 366 |
| 2013 | PETROX, INC | 484.00 | 0.00 | 365 |
| 2014 | PETROX, INC | 585.00 | 0.00 | 365 |
| 2015 | ROULETTE ENERGY LLC | 124.00 | 0.00 | 91 |
| 2016 | ROULETTE ENERGY LLC | 336.00 | 0.00 | 365 |
| 2017 | ROULETTE ENERGY LLC | 280.00 | 0.00 | 365 |
| 2018 | LUOIL INC | 161.00 | 0.00 | 0 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 1985 | QUAKER STATE OIL REF CORP | Brine | 27 | 28 |
| 1986 | QUAKER STATE OIL REF CORP | Brine | 365 | 365 |
| 1987 | QUAKER STATE OIL REF CORP | Brine | 443 | 365 |
| 1988 | QUAKER STATE OIL REF CORP | Brine | 273 | 365 |
| 1989 | QUAKER STATE OIL REF CORP | Brine | 250 | 365 |
| 1990 | QUAKER STATE OIL REF CORP | Brine | 217 | 365 |
| 1991 | QUAKER STATE OIL REF CORP | Brine | 208 | 365 |
| 1992 | QUAKER STATE OIL REF CORP | Brine | 260 | 365 |
| 1993 | QUAKER STATE OIL REF CORP | Brine | 164 | 365 |
| 1994 | QUAKER STATE OIL REF CORP | Brine | 237 | 365 |
| 1995 | BELDEN & BLAKE CORPORATION | Brine | 0 | 122 |
| 1996 | BELDEN & BLAKE CORPORATION | Brine | 356 | 340 |
| 1997 | BELDEN & BLAKE CORPORATION | Brine | 29 | 85 |
| 1998 | BELDEN & BLAKE CORPORATION | Brine | 0 | 365 |
| 1999 | BELDEN & BLAKE CORPORATION | Brine | 0 | 366 |
| 2000 | BELDEN & BLAKE CORPORATION | Brine | 0 | 366 |
| 2001 | BELDEN & BLAKE CORPORATION | Brine | 0 | 366 |
| 2002 | BELDEN & BLAKE CORPORATION | Brine | 0 | 91 |
| 2003 | PETROX, INC | Brine | 35 | 365 |
| 2004 | PETROX, INC | Brine | 120 | 365 |
| 2005 | PETROX, INC | Brine | 230 | 365 |
| 2006 | PETROX, INC | Brine | 84 | 365 |
| 2007 | PETROX, INC | Brine | 365 | |
| 2008 | PETROX, INC | Brine | 29 | 365 |
| 2009 | PETROX, INC | Brine | 113 | 365 |
| 2010 | PETROX, INC | Brine | 299 | 365 |
| 2011 | PETROX, INC | Brine | 513 | 365 |
| 2012 | PETROX, INC | Brine | 167 | 366 |
| 2013 | PETROX, INC | Brine | 0 | 365 |
| 2014 | PETROX, INC | Brine | 0 | 365 |
| 2015 | PETROX, INC | Brine | 0 | 240 |
| 2016 | ROULETTE ENERGY LLC | Brine | 0 | 365 |
| 2017 | ROULETTE ENERGY LLC | Brine | 0 | 365 |
| 2018 | LUOIL INC | Brine | 0 | 0 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -1742165626 | 2018-10-18 0:00 | PW | No Violations | 0.70 |
| -1971279962 | 2017-4-19 0:00: | TD | No Violations | 1.50 |
| -2014332575 | 2012-3-20 0:00: | AD | No Violations | 1.00 |
| -33204660 | 2018-3-30 0:00: | PW | No Violations | 0.50 |
| -540339413 | 2007-9-27 0:00: | AD | No Violations | |
| -704449439 | 2005-2-11 0:00: | AD | No Violations | |
| -942734648 | 2007-5-7 0:00:0 | PW | No Violations | |
| 0033204660 | 2018-03-30 | Production Wells | No Violations | This well has a pumping unit. The tank battery consisted of 2-210 barrel steel tanks and a knockout on a stand. Inside the dike there is also a vertical separator and a chart. |
| 0540339413 | 2007-09-27 | Annular Disposal | No Violations | The well was not equipped for annular disposal. Water was stored in a 210 bbl tank. |
| 0704449439 | 2005-02-11 | Annular Disposal | No Violations | The well is not equipped for annular disposal. There were no violations. |
| 0894210597 | 2018-11-15 | Production Wells | No Violations | The faulty relief valve has been taken out and the well is identified. Violation is resolved. |
| 0909269738 | 2018-08-23 | Production Wells | No Violations | This well is equipped with a pumping unit, tubing, rods and a fairbanks engine. The tank battery consists of 2-210 barrel steel tanks, a knockout and a vertical separator. Altiers said that this well is supposed to be transferred to them from Roulette Energy LLC. |
| 0942734648 | 2007-05-07 | Production Wells | No Violations | There were no violations at the time of inspection. |
| 1075757372 | 2004-01-14 | Annular Disposal | No Violations | Well is not equipped for annular disposal. No violations at the time of inspection.
Well Lat & Long update. Tank battery Lat & Long. |
| 1075757372109701 | 2004-1-14 0:00: | PW | No Violations | |
| 1075757372113474 | 2004-1-14 0:00: | AD | No Violations | |
| 1332941659 | 2012-03-28 | Production Wells | No Violations | Hammer union has been replaced with a 2 ball valve. Peat moss has been thrown over the oil, it has not been removed. |
| 1334236131 | 2012-04-12 | Annular Disposal | No Violations | No clean up yet. |
| 1334841372 | 2012-04-19 | Production Wells | No Violations | Spoke to Scott at Petrox in regards to clean up at well after a visit this morning. gave one week to remove oily materials from dike around wellhead. |
| 1643709143 | 2017-08-08 | Production Wells | No Violations | This well has a pumping unit but is now primarily a gas well. The tank battery consisted of 2-210 barrel steel tanks and a knockout on a stand. Inside the dike there is also a vertical separator and a chart. |
| 1742165626 | 2018-10-18 | Production Wells | Violations Noted | The pop-off was stuck open allowing gas to escape in the area of the pumping tee. I was able to hear and smell the gas from the road. 1501:9-9-05-(B) states; All gas vented to the atmosphere must be flared, with the exception of gas released by a properly functioning relief device and gas released by controlled venting for testing, blowing down and cleaning out wells. Flares must be a minimum of one hundred (100) feet from the well, a minimum of one hundred (100) feet from oil production tanks and all other surface equipment, and one hundred (100) feet from existing inhabited structures and in a position so that any escaping oil or condensate cannot drain onto public roads or towards existing inhabited structures or other areas which could cause a safety hazard. |
| 1971279962 | 2017-04-19 | Temporary Abandoned Annular Disposal | No Violations | Well is not equipped for annular disposal. |
| 2014332575 | 2012-03-20 | Annular Disposal | No Violations | Well is not hooked up for annular disposal. However a 2 line running from the surface casing terminated in a hammer union. A small amount of oil was noticed in the dike around the well head. I called the company and asked them to remove the union and replace it with a plug as well as removed the oil. . |
| 894210597 | 2018-11-15 0:00 | PW | No Violations | |
| 909269738 | 2018-8-23 0:00: | PW | No Violations | 0.30 |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 1742165626 | US-OH-117301 | 2018-10-19 | 9-9-02 | General Safety |
| 1742165626 | US-OH-117302 | 2018-10-19 | 9-9-05(A)10 | Failure to legibly identify well |
| 1742165626 | US-OH-117303 | 2018-10-19 | 9-9-05(A)8 | Equipment pressure rated below operating pressure |
| 1742165626 | US-OH-117304 | 2018-10-19 | 9-9-05(B) | Unlawful venting or flaring of gas |
For data sources see[9]