Well ID: 34-011-20102
Loading map...
Country: United States
State: Ohio
County: Auglaize
Municipality: St. Marys Township
Operator Name: INNEX OIL AND GAS INC
Well Pad ID:
Farm/Lease Name: ELSHOFF
License Status: Final Restoration
License Date: 2013-02-06
Spud Date: 2010-03-12
Spud Drilling Contractor: UNKNOWN OWNER
Final Drill Date: 2010-03-23
Well Total Depth: 2692.00 ft
Configuration: Horizontal
Latitude: 40.540000
Longitude: -84.360000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-01-20 Proposed Formations:TRENTON, Issued Date:1/20/2010, Expired Date:1/20/2011 6:00:00 AM, Drilling unit acres:23.649, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-03-23 STILL TESTING AS OF 4/20/10
Completion Report Received 2010-04-21 STILL TESTING AS OF 4/20/10
Correction to Well 2010-06-04 CHANGE IN TARGET INFORMATION--FROM "AS DRILLED SURVEY"--FOOTAGE= 3498'NL & 2392'EL OF SEC. 2/X= 1,481,137/Y= 325,193/ELEVATION= 887'. UNIT SIZE DECREASED TO 23.217 ACRES.
APP 2013-02-06 Proposed Formations:TRENTON, Issued Date:2/6/2013, Expired Date:2/6/2015 12:00:00 PM, Drilling unit acres:23.649, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2013-04-04 STILL TESTING AS OF 4/20/10
Construction Permit Expires 2015-02-06 STILL TESTING AS OF 4/20/10
Record Last Modified 2015-09-24 STILL TESTING AS OF 4/20/10

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 PERFORATED INTERVAL, TREATMENT, AND RESERVOIR PRESSURE DATA NOT REPORTED …

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 INNEX OIL AND GAS INC 0.00 610.00 197
2011 INNEX OIL AND GAS INC 0.00 209.00 129
2012 INNEX OIL AND GAS INC 0.00 74.00 55
2013 INNEX OIL AND GAS INC 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 INNEX OIL AND GAS INC Brine 56663 197
2011 INNEX OIL AND GAS INC Brine 39779 129
2012 INNEX OIL AND GAS INC Brine 7221 55
2013 INNEX OIL AND GAS INC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1332518997 2011-6-16 0:00: SW No Violations
-1831819915 2013-5-21 0:00: FR No Violations
-418935987 2013-4-4 0:00:0 PB No Violations
-847545698 2013-1-17 0:00: PW No Violations
-870911415 2010-8-25 0:00: SW No Violations
-935573837 2012-1-3 0:00:0 PL No Violations
0056926169 2011-06-16 Salt Water Injection Well No Violations An inspection conducted with Mr. Will Ziegler revealed no violations at this time. During the inspection, it was noted that the Pre-liminary Restoration meets ORC 1509.072. The facility did not contain a concrete vault or unloading pad, as water is not hauled to this location. Identification was observed at the well. The injection pump was not running at time of inspection and positive pressure was not observed with gauge on the annulus.
0096388099 2013-01-30 Production Wells No Violations At the time of my inspection the well was shut in and no longer in production. Mark Amell of Amell Inc. was hired to oversee the plugging of the well for Innex Oil and Gas Inc.
0260341184 2013-03-26 Production Wells No Violations At the time of the inspection the tubing and pump were being removed from the well in preparation for plugging. The rig was operated by Gemini Oil (IN) and was subcontracted by Second Oil Company.
0309542076 2012-12-14 Production Wells No Violations At the time of my inspection the well was not in production and needs serviced.
0418935987 2013-04-04 Plug / Plug Back No Violations At the time of the inspection the well was bailed to 600. A plug was set from 600 to the surface with approximately 6 yards of 9 sack grout. The grout was poured in from the surface inside 7 casing. The 7 casing was cemented to the surface when the well was completed.
0847545698 2013-01-17 Production Wells No Violations At the time of my inspection the well is shut in with the intention to plug and abandon the well.
0870911415 2010-08-25 Salt Water Injection Well No Violations Check well and storage, Pump is running at this time. Has pit at well head that needs to be closed.
0935573837 2012-01-03 Preliminary Restoration No Violations Preliminary Restoration Passed; Also passed by Inspector Brent Bear on 6/16/2011
0986362635 2013-01-14 Production Wells No Violations At the time of my inspection cleanup was almost complete and only a few booms were left in the ditch to trap any remaining oil. At this time both production wells are shut in and Innex Oil and Gas plans to Plug and Abandon all three wells on the site. Cleanup efforts still conducted by Allied Envronmental under the supervision of Ohio EPA and AuglaizeCounty EMA.
1133284913 2013-04-01 Plug / Plug Back No Violations At the time of the inspection Jet Wire Line Services were on site and set an Owen 5.91 (6.25 to 7.5) bridge plug at 1210.
1285862085 2010-09-30 Salt Water Injection Well No Violations Check well and storage.

The injection pump is not running at this time. Annulus has positive pressure but not enough to measure. No odors at this time.

1297442577 2011-02-11 Salt Water Injection Well No Violations The site is snow covered, approx temp 16 degrees F.

The valves on the annulus are under ice and can not be opened at this time.

1332518997 2011-06-16 Salt Water Injection Well No Violations I inspected the well location with Brent Bear. See Bears report for details.
1358867689 2013-01-12 Production Wells Violations Noted At the time of my inspection I was called outbecause of a release of oil on site. The high level shut off switch in the oil tank had failed around 10:30 pm on 1-11-13 and caused the tank to overflow into the containment dike of the tank battery. A submersibal pump with an automatic switch was in the dike to remove rainwater and came on when the dike filled with oil. The setup of an automated submersible pump was not in the operating plan nor was it approved by the Division of Oil & Gas as indicated in the Permit Application. This put oil on the ground outside the lined dike. The oil eventually made it into a field tile then to a ditch 400 to the east. The oil then flowed 1000 south to where the ditch empties into the East Branch of Clear Creek. The high level of Clear Creek at the time prevented any flow from the ditch into Clear Creek so it is believed that no oil made it past this point. Cleanup efforts were conducted by Allied Environmental under the supervision of Dave Schilt, Ohio EPA, and Troy Anderson, Auglaize County EMA. Cleanup efforts were completed, with the exception of the monitoring of the ditch, by 1-16-2013. Officials from Innex have indicated they intend to plug and abandon all three wells on this lease.
1831819915 2013-05-21 Final Restoration No Violations At the time of the inspection all plugging operation were completed and all equipment had been removed from the location. The location is in a farm field and was graded by the plugging contractor. The location was tilled and planted by the landowner. Final Restoration Passed.
1862588286 2011-06-16 Salt Water Injection Well No Violations An inspection conducted with Mr. Will Ziegler revealed that the Preliminary Restoration meets ORC 1509.072. No injection at time of inspection. The annulus did not have positive pressure at time of inspection. It was also noted that the facility did not contain a concrete vault or unloading pad. RBDMS currently shows well status as DR.
1989843351 2011-11-21 Production Wells No Violations Well is shut in and being serviced. ID posted but has incorrect API #. Sign is posted as 20103 and needs to be 20102. Signs on both wells need switched with each other. I talked with operator who will do so when wells get serviced.
2125792414 2013-04-03 Plug / Plug Back No Violations At the time of the inspection a bottom plug was set on top of the bridge plug (set on 4-1-13 at 1210) from 1200 to 970 with 40 sacks of 50/50 pozmix from PetroSet Cementing Services. The cement was pumped through 1.5 tubing and no circulation was observed. The cement will be tagged with the bailer after 24 hours to determine the top of the plug.
260341184 2013-3-26 0:00: PW No Violations
309542076 2012-12-14 0:00 PW No Violations
56926169 2011-6-16 0:00: SW No Violations 4.50
96388099 2013-1-30 0:00: PW No Violations
986362635 2013-1-14 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1358867689 US-OH-110409 2013-01-24 Well operation causing pollution and contamination
1358867689 US-OH-110410 2013-01-24 No SPCC dike/or failure to keep dike free of water or oil
1358867689 US-OH-110411 2013-01-24 Dike or pit not able to prevent escape of brine or other wastes