{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.03,"lon":-80.81,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Pultney Township | |
Operator Name: EQUITY OIL & GAS FUNDS INC | |
Well Pad ID: | |
Farm/Lease Name: KEYSER | |
License Status: Plugged and Abandoned | |
License Date: 2019-04-19 | |
Spud Date: 1979-05-08 | |
Spud Drilling Contractor: | |
Final Drill Date: 1979-05-15 | |
Well Total Depth: 2450.00 ft | |
Configuration: Vertical | |
Latitude: 40.030000 | |
Longitude: -80.810000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1978-12-29 | 508 M C F OIL CO INC GeoDate 12/29/78 |
Original Spud | 1979-05-08 | |
Completed | 1979-05-15 | |
Reached Total Depth | 1979-05-15 | |
CO | 1994-10-26 | 2512 MILLER WILLIAM S INC GeoDate 12/29/78 |
Change of Owner | 1998-12-15 | Operator changed from 2512, MILLER WILLIAM S INC to 5429, MILEY GAS COMPANY |
Change of Owner | 2005-09-19 | Operator changed from 5429, MILEY GAS COMPANY to 1171, EQUITY OIL & GAS FUNDS IN |
APP | 2019-04-19 | Proposed Formations:GORDON, Issued Date:4/19/2019, Expired Date:4/18/2021 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Record Last Modified | 2019-04-26 | |
Construction Permit Expires | 2021-04-18 |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | EQUITY OIL & GAS FUNDS INC | 72.00 | 0.00 | 365 |
2008 | EQUITY OIL & GAS FUNDS INC | 97.00 | 0.00 | 365 |
2009 | EQUITY OIL & GAS FUNDS INC | 647.00 | 0.00 | 365 |
2010 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 365 |
2011 | EQUITY OIL & GAS FUNDS INC | 51.00 | 0.00 | 365 |
2012 | EQUITY OIL & GAS FUNDS INC | 294.00 | 0.00 | 365 |
2013 | EQUITY OIL & GAS FUNDS INC | 64.00 | 0.00 | 365 |
2014 | EQUITY OIL & GAS FUNDS INC | 182.00 | 0.00 | 185 |
2015 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 0 |
2016 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 0 |
2017 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2008 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2009 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2010 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2011 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2012 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2013 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2014 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 185 |
2015 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 0 |
2016 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 0 |
2017 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1146147002 | 2019-9-9 0:00:0 | PW | No Violations | 0.50 |
-1514828885 | 2017-8-25 0:00: | PW | No Violations | 1.00 |
-987675379 | 2020-9-2 0:00:0 | FR | No Violations | 1.50 |
1354630232 | 2012-12-04 | Production Wells | No Violations | On the day of my inspection the well was complete with a pumping unit and capable of production. Tank battery contents included: one 50 bbl storage tank and a mechanical separator. I will make contact with the company and inform them they need to supply state with proper documentation of production. |
1408391621 | 2014-08-18 | Production Wells | No Violations | Onsite with Inspector Andrew Corder. Tank battery contains 50bbl poly tank and a mechanical seperator. Well appears to have all needed production equipment. See his report this date for further information. |
1514828885 | 2017-08-25 | Production Wells | No Violations | This well is equipped with a pumping unit, tubing, rods and 4.5-inch diameter casing. The pumping unit is connected to the rods. The pumping unit did contain a motor that was powered by electric. The production area contained one 25-barrel production fluid holding tank and a vertical mechanical separator. This well has not shown production since 2015. |
1524464209 | 2014-08-18 | Production Wells | No Violations | On the day of my inspection the well was equipped with necessary equipment to be capable of production. Tank battery contents included: one 50 bbl storage tank and a mechanical separator. Production records have been submitted. No violations noted. |
1551198061 | 2019-02-26 | Production Wells | No Violations | Status check inspection found the well equipped with 4.5 diameter casign and 1.900 diameter production tubing with the well set up to be produced by the means of a pumping unit. 2 diameter flow lines are present and attached to the tubing and casing well heads. The flow lines are equipped with shut off and check valves. The tubing head head valve is closed the casign head valve is open. The well is set up to be produced by the means of a pumping unit driven by an electrical motor. The electrical meter has been pulled. The production facility consists of a gas sales meter and mechenical separator. There is no sales chart in the meter and a the production tank is a 2,100 gallon plastic tank. |
1570551247 | 2019-10-8 0:00: | PB | No Violations | 9.00 |
1570629752 | 2019-10-9 0:00: | PB | No Violations | 1.00 |
192281354 | 2020-7-15 0:00: | FR | No Violations | 0.30 |
1970626099 | 2018-11-13 | Production Wells | No Violations | On the day of my inspection I witnessed production equipment included a 37-barrel plastic production fluid storage tank, vertical separator, drip and 2-inch diameter meter run with a .250-inch diameter orifice all contained within an earthen dike. There was no chart in the meter at the time of my inspection. The well was equipped with 4.5-inch diameter production casing, 1.5-inch diameter tubing and rods with a Churchill pumping unit and an electric motor. The casing valve on the well head was open at the time of my inspection and the tubing valve was closed. There was an identification tag on the production equipment that did not have any info on it, production has been reported as 0 since 2014. |
355614709 | 2020-7-15 0:00: | FR | No Violations | 0.40 |