If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-20306 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.04,"lon":-80.77,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Pultney Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: COWEN ROBERT | |
License Status: Producing | |
License Date: 1980-02-18 | |
Spud Date: 1980-03-27 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-03-31 | |
Well Total Depth: 2097.00 ft | |
Configuration: Vertical | |
Latitude: 40.040000 | |
Longitude: -80.770000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-02-18 | 508 M C F OIL CO INC GeoDate 2/18/80 |
Original Spud | 1980-03-27 | R.I. 2-20-80 |
Completed | 1980-03-31 | R.I. 2-20-80 |
Reached Total Depth | 1980-03-31 | R.I. 2-20-80 |
CO | 1994-10-26 | 2512 MILLER WILLIAM S INC GeoDate 2/18/80 |
Change of Owner | 1998-12-15 | Operator changed from 2512, MILLER WILLIAM S INC to 5429, MILEY GAS COMPANY |
Change of Owner | 2005-09-19 | Operator changed from 5429, MILEY GAS COMPANY to 1171, EQUITY OIL & GAS FUNDS IN |
Record Last Modified | 2013-12-27 | R.I. 2-20-80 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 1307 | 1329 | 34 |
2006-09-11 | 2003 | 2007 | 1 |
1307 | 1329 | 34 | |
1307 | 1329 | 34 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 18500 Gal | 11000 | 2ND STAGE | ||
H2O | 0 | 42500 Gal | 35500 | |||
H2O | 0 | 24000 Gal | 24500 | 1ST STAGE |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | WILLIAM S MILLER INC | 43.00 | 0.00 | 92 |
1995 | WILLIAM S MILLER INC | 194.00 | 0.00 | 365 |
1996 | WILLIAM S MILLER INC | 15.00 | 0.00 | 365 |
1997 | WILLIAM S MILLER INC | 3.00 | 0.00 | 365 |
2007 | EQUITY OIL & GAS FUNDS INC | 185.00 | 0.00 | 365 |
2008 | EQUITY OIL & GAS FUNDS INC | 416.00 | 0.00 | 365 |
2009 | EQUITY OIL & GAS FUNDS INC | 346.00 | 0.00 | 365 |
2010 | EQUITY OIL & GAS FUNDS INC | 49.00 | 0.00 | 365 |
2011 | EQUITY OIL & GAS FUNDS INC | 80.00 | 0.00 | 0 |
2012 | EQUITY OIL & GAS FUNDS INC | 727.00 | 0.00 | 365 |
2013 | EQUITY OIL & GAS FUNDS INC | 61.00 | 0.00 | 365 |
2014 | EQUITY OIL & GAS FUNDS INC | 181.00 | 0.00 | 185 |
2015 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 0 |
2016 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 0 |
2017 | EQUITY OIL & GAS FUNDS INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1994 | WILLIAM S MILLER INC | Brine | 0 | 92 |
1995 | WILLIAM S MILLER INC | Brine | 0 | 365 |
1996 | WILLIAM S MILLER INC | Brine | 0 | 365 |
1997 | WILLIAM S MILLER INC | Brine | 0 | 365 |
2007 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2008 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2009 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2010 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2011 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | |
2012 | EQUITY OIL & GAS FUNDS INC | Brine | 70 | 365 |
2013 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 365 |
2014 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 185 |
2015 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 0 |
2016 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 0 |
2017 | EQUITY OIL & GAS FUNDS INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1682406715 | 2006-1-27 0:00: | PW | No Violations | |
-384570434 | 2017-8-25 0:00: | PW | No Violations | 1.00 |
-599188884 | 2008-10-15 0:00 | PW | No Violations | |
-613454333 | 2007-1-31 0:00: | PW | No Violations | |
-88711453 | 2018-3-19 0:00: | PW | No Violations | 0.50 |
0069128482 | 2018-11-06 | Production Wells | No Violations | Accompanied ODNR inspector Bill Stolarik, please reference his report for further details. |
0088711453 | 2018-03-19 | Production Wells | No Violations | On the day of my inspection the well was equipped with a pumping unit, 2-inch diameter tubing, and rods. The production casing is 4.5-inches in diameter. There was an electric motor present on the pumping unit. The motor had belts that were attached from the motor to the pumping unit. The pitman arm appeared to be broken and was not attached to the motor. Near the well was a 100-barrel production fluid holding tank and a vertical mechanical separator. There was a pumping unit on site that was not attached to the well that appeared to be in operating condition. Production records within RBDMS show production up to 2014 with zero production reported after. |
0384570434 | 2017-08-25 | Production Wells | No Violations | This well is equipped with a pumping unit, tubing, and rods and 4.5-inch diameter casing. The pumping unit is connected to the rods. The pumping unit did contain a motor and belts. The production area contained two 100-barrel production fluid holding tanks and a vertical mechanical separator. This well has no shown production since 2014. |
0430568090 | 2011-02-09 | Production Wells | No Violations | On day of inspection well is supplied with pump jack and 8cas,4.5cas,2 3/8 upset tubing. There is a 100bbl tank. Dike and id are in place.No violations. |
0599188884 | 2008-10-15 | Production Wells | No Violations | WORK OVER OF WELL IN PROGRESS. |
0613454333 | 2007-01-31 | Production Wells | No Violations | STATUS CHECK WITH JOHN MURPHY |
1541518739 | 2018-11-06 | Production Wells | No Violations | On site inspection accompanied by ODNR Inspector Ryan Armstrong found the well is equipped with 4.5 diameter production casing with 2.375 diameter non upset tubing. The well is equipped with 2 diameter production flow lines attached to the casing and tubing well heads, production valves are present on both the tubing and casing well heads with both valves being in the closed position. A pressure gauge is present on the 4.5 diameter casing service outlet valve, the pressure gauge reads 270 pounds pressure. There is a polish rod liner and pumping rods installed into the production tubing and the well is set up to be produced by the means of an electrical motor driven pumping unit. It appears as a new pumping unit has been set recently and several new valves and gauges have been installed on the well head. The electrical service is intact and also appears to be active to the well head. On location near the well head is the production facility consisting of a steel construction 100 barrel production tank along with a mechanical separator. The bottom 2 valve on the production tank is open with a 2 line leading to a underground culvert, the tank battery appears to be out of service. The area was photographed and discussed with my Supervisor Brent Bear. A meeting will be set up with the company to discuss the line running to the culvert. The meter for the well is located at a second tank battery situated along the lease road to the well. The second tank battery was shared with 3401320588-0000. The production flowlines were configured in such a way it was unclear on this day if the production tank located near the said well 3401320306-0000 was in service. Production records are current in the State database however no commercial production has been reported for the last 3 reporting years. The current registered owners have indicated they are in the process of transferring the wells. |
1682406715 | 2006-01-27 | Production Wells | No Violations | NON-PRODUCING |
430568090 | 2011-2-9 0:00:0 | PW | No Violations | 1.00 |
647665315 | 2020-2-28 0:00: | PW | No Violations | 0.70 |
69128482 | 2018-11-6 0:00: | PW | No Violations |
For data sources see[9]