{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.04,"lon":-80.8,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Pultney Township | |
Operator Name: EQUITY OIL & GAS FUNDS INC | |
Well Pad ID: | |
Farm/Lease Name: THORNTON G & A | |
License Status: Final Restoration | |
License Date: 2014-05-28 | |
Spud Date: 1980-01-08 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-01-24 | |
Well Total Depth: 2077.00 ft | |
Configuration: Vertical | |
Latitude: 40.040000 | |
Longitude: -80.800000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-01-04 | 508 M C F OIL CO INC GeoDate 1/4/80 |
Original Spud | 1980-01-08 | |
Completed | 1980-01-24 | |
Reached Total Depth | 1980-01-24 | |
CO | 1994-10-25 | 2512 MILLER WILLIAM S INC GeoDate 1/4/80 |
Change of Owner | 1998-12-15 | Operator changed from 2512, MILLER WILLIAM S INC to 5429, MILEY GAS COMPANY |
Change of Owner | 2005-09-19 | Operator changed from 5429, MILEY GAS COMPANY to 1171, EQUITY OIL & GAS FUNDS IN |
APP | 2014-05-28 | Proposed Formations:BEREA, Issued Date:5/28/2014, Expired Date:5/27/2016 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2014-06-05 | |
Construction Permit Expires | 2016-05-27 | |
Record Last Modified | 2017-02-10 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 1014 | 1018 | 8 |
2006-09-11 | 1190 | 1200 | 8 |
1014 | 1018 | 8 | |
1014 | 1018 | 8 | |
2006-09-11 | 1915 | 1918 | 8 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 12000 Gal | 20000 | |||
H2O | 0 | 20000 Gal | 30000 | |||
H2O | 0 | 20000 Gal | 30000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-226461331 | 2014-8-18 0:00: | FR | No Violations | 1.00 |
-289831167 | 2014-6-4 0:00:0 | PB | No Violations | 5.00 |
0226461331 | 2014-08-18 | Final Restoration | No Violations | On the day of my inspection the final restoration on this property was satisfactory. Final restoration is now complete. No violations noted. |
0289831167 | 2014-06-04 | Plug / Plug Back | No Violations | On the day of my inspection the plugging of this well commenced. The plugging of this well satisfies Compliance Notice Inspection #1395924374. All compliance notices are now resolved. See plugging report for further details. |
1395924374 | 2014-03-03 | Production Wells | Violations Noted | On the day of my inspection I found no domestic gas in use; the lead line is disconnected from the well head; this line is used to transport production to the storage tank. The lack in completed piping to the tank battery demonstrated that this well was unable to produce. The well did not have any tubing or rods. There was no pumping unit present on the location. I took photos of the well. The well did not have the proper identification present. The well has not had any production records filled. Due to the facts noted above this well is required to be plugged in 180 days. This well has been plugged and all compliance issues are now RESOVLED Reference: Inspection # -289831167 |
1541064368 | 2018-10-31 | Final Restoration | No Violations | On 10/31/2018 I walked the plotted area of the well accompanied by ODNR Inspector Ryan Armstrong. No well was found and no production equipment was present. I also spoke with the landowner who confirmed the well was plugged and all equipment removed. The Final Restoration has been passed. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1395924374 | US-OH-111713 | 2014-06-30 | Failure to legibly identify well | |
1395924374 | US-OH-111714 | 2014-06-30 | Well shall be plugged | |
1395924374 | US-OH-111715 | 2014-06-30 | Nonproduction; well shall be plugged or placed in temporary inactive status | |
1395924374 | US-OH-111716 | 2014-06-30 | Statement of annual production not filed | |
1395924374 | US-OH-111717 | 2014-06-30 | Failure to report production to royalty holders |