If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-20493 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.97,"lon":-81.22,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Warren Township | |
Operator Name: SOUND ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: CARPENTER JIMMIE | |
License Status: Producing | |
License Date: 1985-09-06 | |
Spud Date: 1985-09-19 | |
Spud Drilling Contractor: W PUTNAM DRLG | |
Final Drill Date: 1985-09-26 | |
Well Total Depth: 2028.00 ft | |
Configuration: Vertical | |
Latitude: 39.970000 | |
Longitude: -81.220000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1985-09-06 | 2 BLAUSER WELL SERVICE INC GeoDate 9/6/85 |
Oil and Gas | 1985-09-06 | Issued Date 9/6/85 Expired Date 9/6/86 Acres 0059370 Tool Type RTA Proposed Formation BEREA Proposed Depth 02028 Proposed Drill Depth 02028 |
Original Spud | 1985-09-19 | |
Completed | 1985-09-26 | |
Reached Total Depth | 1985-09-26 | |
Completion Report Received | 1986-01-30 | |
Construction Permit Expires | 1986-09-06 | |
Change of Owner | 2018-01-09 | Operator changed from 2, BLAUSER ENERGY CORPORATION to 4327, SOUND ENERGY CO INC |
Record Last Modified | 2018-01-09 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 1805 | 1812 | 24 |
1805 | 1812 | 24 | |
1805 | 1812 | 24 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 750 Gal | 0 | LOG ATTACHED | ||
H2O | 0 | 785 Bbl | 57000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0005604i52 | 2002-01-29 | Production Wells | No Violations | |
0406612748 | 2017-07-20 | Production Wells | No Violations | This well is equipped with 4.5-inch diameter production casing. It also has tubing and rods installed in the well. Attached to the rods was a pumping unit. The pumping unit had a motor on it that appeared to be powered by means of electric. There was an electric pole with a box beside the pumping unit with an electric line ran to the motor. The motor had belts that were attached from it to the pumping unit. The production area contained two 100 barrel production fluid storage tanks, a vertical mechanical separator, and a gravity separation unit on top of one of the 100 barrel tanks. Production records within the RBDMS system are current up to 2016. I spoke with the landowner concerning the well and she told me that domestic gas was currently being utlized from the well. |
0791723982 | 2018-06-19 | Production Wells | No Violations | On the day of my inspection I witnessed Production equipment included 2- 100 barrel tanks, and a vertical separator contained within an earthen dike. The well was equipped with 4.5-inch diameter production casing, and 1.5 inch diameter tubing with rods, and a Churchill Pumping unit with an electric motor. The well head was equipped with a domestic gas line on the opposite side of the production lines. There was a back pressure regulator or controlling device allowing gas to vent into the atmosphere. There was also a small area of oil contamination on the ground near the well head approximately 6 square feet. There were no identification tags on the well or production equipment. I contacted Nathan Levengood, and Bruce Levengood from Sound Energy and informed them of the problems and he said that he would remediate the problems in the next couple of days. I plan to check on the well later in the week to see if the violations have been taken care of. |
406612748 | 2017-7-20 0:00: | PW | No Violations | 2.50 |
5604i52 | 2002-1-29 0:00: | PW | No Violations | |
791723982 | 2018-6-19 0:00: | PW | No Violations | 1.20 |
For data sources see[9]