{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.06,"lon":-80.78,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Pease Township | |
Operator Name: DAVID R HILL INC | |
Well Pad ID: | |
Farm/Lease Name: GEORGETOWN MARINE (SWIW #1) | |
License Status: Final Restoration | |
License Date: 2014-06-30 | |
Spud Date: 2010-09-14 | |
Spud Drilling Contractor: WARREN DRLG | |
Final Drill Date: 2010-12-06 | |
Well Total Depth: 13727.00 ft | |
Configuration: Vertical | |
Latitude: 40.060000 | |
Longitude: -80.780000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-05-28 | Proposed Formations:BEREA THRU MT. SIMON, Issued Date:5/28/2010, Expired Date:5/28/2011 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:EDPW |
Correction to Well | 2010-06-04 | CORRECTION TO CASING PROGRAM: SHOULD BE 13 3/8" MINIMUM OF 1500' CEMENT CIRCULATED TO SURFACE. |
Reached Total Depth | 2010-12-06 | SPUD 36' CONDUCTOR HOLE ON 9/14. SET & CEMENT 60' OF 30" CONDUCTOR ON 9/15. WARREN DRLG COMMENCED SURFACE HOLE ON 10/2/2010 |
Completion Report Received | 2011-05-06 | SPUD 36' CONDUCTOR HOLE ON 9/14. SET & CEMENT 60' OF 30" CONDUCTOR ON 9/15. WARREN DRLG COMMENCED SURFACE HOLE ON 10/2/2010 |
APP | 2011-06-13 | Proposed Formations:BEEKMANTOWN THRU MT SIMON, Issued Date:6/13/2011, Expired Date:6/12/2013 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Last Compliance Report | 2011-06-13 | SPUD 36' CONDUCTOR HOLE ON 9/14. SET & CEMENT 60' OF 30" CONDUCTOR ON 9/15. WARREN DRLG COMMENCED SURFACE HOLE ON 10/2/2010 |
APP | 2014-06-30 | Proposed Formations:BEEKMANTOWN - MT. SIMON, Issued Date:6/30/2014, Expired Date:6/29/2016 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Plugged/Abandoned | 2014-10-21 | SPUD 36' CONDUCTOR HOLE ON 9/14. SET & CEMENT 60' OF 30" CONDUCTOR ON 9/15. WARREN DRLG COMMENCED SURFACE HOLE ON 10/2/2010 |
Record Last Modified | 2015-09-24 | SPUD 36' CONDUCTOR HOLE ON 9/14. SET & CEMENT 60' OF 30" CONDUCTOR ON 9/15. WARREN DRLG COMMENCED SURFACE HOLE ON 10/2/2010 |
Construction Permit Expires | 2016-06-29 | SPUD 36' CONDUCTOR HOLE ON 9/14. SET & CEMENT 60' OF 30" CONDUCTOR ON 9/15. WARREN DRLG COMMENCED SURFACE HOLE ON 10/2/2010 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2011-06-13 | 11842 | 13596 | 742 |
11842 | 13596 | 742 | |
11842 | 13596 | 742 |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | DAVID R HILL INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2014 | DAVID R HILL INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-100403355 | 2010-10-25 0:00 | DD | No Violations | 3.00 |
-1032874155 | 2010-9-14 0:00: | DD | No Violations | 4.50 |
-1062131425 | 2014-10-14 0:00 | SW | No Violations | |
-1122835590 | 2010-10-16 0:00 | DD | No Violations | |
-1239619756 | 2014-1-27 0:00: | SW | No Violations | |
-1314219756 | 2010-10-21 0:00 | DD | No Violations | 1.50 |
-135490825 | 2010-10-14 0:00 | DD | No Violations | 8.00 |
-1425164820 | 2010-12-9 0:00: | DD | No Violations | |
-1491570748 | 2013-2-20 0:00: | SW | No Violations | |
-1502985628 | 2010-10-7 0:00: | DD | No Violations | 14.50 |
-1534579919 | 2014-11-14 0:00 | FR | No Violations | |
-1667542803 | 2014-6-17 0:00: | SW | No Violations | |
-1731939519 | 2013-11-27 0:00 | SW | No Violations | |
-1855289927 | 2010-11-8 0:00: | DD | No Violations | 1.00 |
-1873370173 | 2013-9-24 0:00: | SW | No Violations | |
-1891693600 | 2012-2-22 0:00: | SW | No Violations | |
-1930920079 | 2012-2-21 0:00: | SW | No Violations | |
-2063558525 | 2012-9-25 0:00: | SW | No Violations | |
-276064887 | 2010-11-17 0:00 | DD | No Violations | 1.00 |
-278619610 | 2012-11-14 0:00 | SW | No Violations | |
-287138489 | 2014-10-21 0:00 | SW | No Violations | |
-314689779 | 2014-10-16 0:00 | SW | No Violations | 4.00 |
-344848633 | 2012-6-21 0:00: | SW | No Violations | 2.00 |
-354020615 | 2010-7-21 0:00: | DD | No Violations | 1.00 |
-410909586 | 2010-11-29 0:00 | DD | No Violations | 2.00 |
-438052215 | 2014-8-19 0:00: | SW | No Violations | |
-795689798 | 2013-4-5 0:00:0 | SW | No Violations | 3.00 |
-855439873 | 2013-2-1 0:00:0 | SW | No Violations | |
-936473187 | 2011-2-9 0:00:0 | CT | No Violations | 0.50 |
0045575311 | 2011-06-14 | Salt Water Injection Well | No Violations | On day of inspection MIT test was being performed on well. DNR Inspectors Farnesworth,Corder and I were present. |
0065800577 | 2014-10-08 | Salt Water Injection Well | No Violations | Kilbarger rig 17 on site preparing to attempt to release packer and pull it from wellbore and after several failed attempts they were finally able to release it and they started to pull it from well. |
0073694681 | 2010-11-05 | Drill / Deepen / Reopen | No Violations | On site to witness testing of BOP stack choke manifold was tested at 4000# with no decline in pressure and pipe rams were tested @4000# with no decline and blind rams were tested@4000# and annular was tested@1000# with no decline in pressure work was preformed by Triple J Oilfield Services of New Martinsville West Virginia. |
0100403355 | 2010-10-25 | Drill / Deepen / Reopen | No Violations | On day of inspection stopped in to check rig and they were at depth of 6455.Met with Dave Hill, Don Kreagor and State Rep.Dominic. |
0135490825 | 2010-10-14 | Drill / Deepen / Reopen | No Violations | On day of inspection Warren drilling is setting 2079of 13 3/8casing in 210117.5openhole.Good circulation.60bbl of cement returns. |
0217464141 | 2011-02-28 | Completion Testing | No Violations | On day of inspection Energy Contractor Service rig is running 3 1/2casing in well. Pipe is range 2 and is 9.3lb /ft.There is a Baker set Packer ran and is a 1528tail pipe below packer. Top perf is at 12,271and bottom perf is at 13,652.There is 70 ft of fill at bottom after pipe is ran a mud push will be ran to circulate hole clean. Then they will run in set packer and un-J packer at top and circulate hole with a oxygen scavenger and a packer inhibiter. |
0276064887 | 2010-11-17 | Drill / Deepen / Reopen | No Violations | On day of inspection well was at depth of 11,478.Company is at a 31 visc and 10.4ppgmud weight. Company is in the St.Peters formation. Very slow drilling. |
0278619610 | 2012-11-14 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection. It was noted that one Buckeye Water Services truck was unloading at facility during my inspection.
Note: Exposed portion of liner in tank area needs to be covered with stone too help prevent rotting due to exposure to sunlight. |
0287138489 | 2014-10-21 | Salt Water Injection Well | No Violations | On site to witness plugging operation and plugs were set at required depths and cement stayed up good at surface. |
0289658700 | 2013-06-27 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: Well is not in operation at this time owner is planning on plugging well back to a producing zone in the near future. |
0314689779 | 2014-10-16 | Salt Water Injection Well | No Violations | |
0344848633 | 2012-06-21 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and according to well tender they are receiving approximately 300 bbl of brine daily and they are monitoring annulus of tubing to ensure that there is no pressure increases while pumping down into injection formations. |
0354020615 | 2010-07-21 | Drill / Deepen / Reopen | No Violations | On day of inspection Stonerock and I met with Dave Lucas at the proposed site. |
0410909586 | 2010-11-29 | Drill / Deepen / Reopen | No Violations | On day of inspection per request of Tugend I inspected around pit for a possible leak. There was no apparent leak but there was a tank that run over after pumping fluid from pit to 500bbl tanks. The company took measures to clean up mud on the site. The area was purged with fresh water. |
0419637017 | 2011-03-03 | Completion Testing | No Violations | Arrived on location at 7:00am. Swivel being tore down. Getting ready to set packer. Packer was set at 11:40 AM. There was pressure on the tubing because 30 barrels of fresh water was pumped in on a homogenized system. Universal broke formation at 3,850 PSI. Well pressured up and sat at 4,000 PSI for 1/2 hour. Well pressured up to 5,300 PSI and let set for 1/2hr at 5 bbl per minute. Decided to shut down at 1:43pm. To return in the morning. |
0438052215 | 2014-08-19 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on service rig to plug said well and according company rep the owner is planning on plugging well next month. |
0510950934 | 2014-07-15 | Salt Water Injection Well | No Violations | Inspection revealed that owner has received plugging permit and they plan on performing required work on well next month. |
0517894390 | 2010-11-04 | Drill / Deepen / Reopen | No Violations | On day of inspection Halliburton is in to set 47lb/ft of 9 5/8 casing at depth of 8338.The open hole is at depth of 8382 and is 12.25diameter.There is stinger tool ran at a depth of 8291.The casing is ran in on a hanger in the 13 3/8cas.Company is displacing the cement through the 4 1/2drillpipe at 16.60 /lb.Halliburton ran a Halcem system that required 1500sks of cement 1.25 yield and 15.6ppg.Good circulation and good well conditions. |
0543401270 | 2014-02-19 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on plugging permit to be issued. |
0564788252 | 2013-08-14 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time and in conversation with owner stating that they plan on possibly plug well back too a producing formation in the near future. |
0604469729 | 2012-08-29 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that restoration work at site is nearly complete, told operator that there was one area on slope below site that needed seeded and mulched and once vegetation was established I would pass restoration work. |
0661352063 | 2011-03-28 | Completion Testing | No Violations | On day of inspection Appalachian surveys were making gun runs to the beekmantown formation. Don Kreagor stated that company will acidize Wednesday. |
0774243355 | 2012-12-13 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and well tender stated that they were slow this week.
Note: Exposed portion of liner still needs to be covered with stone to help prevent damage to it due to fact of exposure to sunlight. |
0795689798 | 2013-04-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and owner is not using well much due to economic reasons. |
0805705950 | 2013-12-16 | Salt Water Injection Well | No Violations | Inspection revealed that well is down awaiting on plugging permit to be issued and once issued owner plans on plugging said well. |
0855439873 | 2013-02-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today due too in climate weather conditions.
Note: Exposed portions of liner in tank area still needs to be covered to help prevent rotting due to exposure to sunlight. |
0936473187 | 2011-02-09 | Completion Testing | No Violations | On day of inspection Energy Contractor rig will be moving in on location. |
1032874155 | 2010-09-14 | Drill / Deepen / Reopen | No Violations | On day of inspection Butchs rat hole drilling rig came in to site and started drilling conductor hole. Drilled a 36hole and set 30casing to a depth of 55.Will grout on 9-15-2010. |
1062131425 | 2014-10-14 | Salt Water Injection Well | No Violations | On site to set 9.625 bridge plug and bond log casing to determine where pipe is free to cut when they get ready to perform task. |
1087420287 | 2014-10-31 | Salt Water Injection Well | No Violations | Inspection revealed that storage tanks are being cleaned out and waste material is being solidified and hauled to a approved landfill and once tanks are out of the way restoration work will begin. |
1122835590 | 2010-10-16 | Drill / Deepen / Reopen | No Violations | On this day Don Kreagor called and notified me of BOP test for the 13 3/8to 12 1/4openhole. |
1168522894 | 2010-10-06 | Drill / Deepen / Reopen | No Violations | On day of inspection Warren drilling rig 12 is setting 465of 20casing in a 490of 26openhole.Haliburton is cementing the casing. Pipe is not going together very well. This is buttress thread pipe. Ran 3 20baskets.Well did not circulate and could not get the cement to fill up the backside. Will grout and cut pipe off. |
1238318900 | 2013-03-21 | Salt Water Injection Well | No Violations | Well is not used much at this time due to lack of clean brine water. |
1239619756 | 2014-01-27 | Salt Water Injection Well | No Violations | Inspection revealed that well is still out of service waiting on plug permit to be issued and owner stating that once permit is issued he plans on plugging well. |
1291632449 | 2010-11-29 | Drill / Deepen / Reopen | No Violations | On day of inspection Warren rig #12 was drilling and was at a depth of 12996.They are drilling in proposed Rome. |
1298984444 | 2011-02-25 | Completion Testing | No Violations | On day of inspection we getting started. Total 423 jts of 3 1/2casing on rack. I contacted by E-mail Tomastic on top pressure and water variance. Company shut down early because of bad weather. |
1299155576 | 2011-03-02 | Completion Testing | No Violations | Arrived on location at 10:am. Universal Well Services were on location and hooked up. Company is at 13,519 with Packer. Tubing swivel was hooked up and would not work. Brought in a power swivle. Washed in to 13,650. Company started to add another joint and it kept pressuring up. Pulled that joint and circulated Mud Push to clean well. Spotted 2200 gallons of acid and let set overnight. Average pressure was 2200 PSI. Left at 6:00pm. |
1299243081 | 2011-03-04 | Completion Testing | No Violations | Arrived at location at 7:00am.Pressure is at 0psi. |
1300388911 | 2011-03-17 | Completion Testing | No Violations | On day of inspection well packer was set at 12,205and removable bridge plug was at 12,855.There was 500gal of 28%HCL and 3000gal of 15%HCL. A step test was performed by Universal well services. Upon waiting for flow back to quit we got started at 10:00am.1/2 bbl per minute at 1,000psi.At 10:40am went to 1 bbl/min and had 90bbl in at 1300psi.At 12:49pm was at 1.5bbl/min and3160psi.Shut in pressure was at 2950psi.After pressure dropped back got off and went back to bridge plug and released it. Will circulate well bottoms up and clean all residual acid from well and pull up to 12,205 with bridge plug. |
1301498408 | 2011-03-28 | Completion Testing | No Violations | Pat Shreve and I inspected this site. Appalachian Surveys were perforating the Beekmantown formation. Don Kreager was present. The earthing pits on this location were satisfactory. |
1314219756 | 2010-10-21 | Drill / Deepen / Reopen | No Violations | On day of inspection rig 12 is drilling at a depth of 5230.They drilling 45 min Kelly. Getting ready to run survey. |
1329869373 | 2012-02-21 | Salt Water Injection Well | No Violations | On site to witness Eastern Wireline company set plug in packer and pressure test tubing company rep pressured up on tubing too 2400 psi and we monitored pressure for 15 min with no decline so it was determined that packer element has lost integrity so decision was made to release packer tomorrow and then pull it from well and have it rebuilt and then run it back in well and reset and test to maximum injection pressure. |
1330386092 | 2012-02-27 | Salt Water Injection Well | No Violations | On site to witness Baker Oil Tool company rep start packer and tubing back into well they will continue to run tubing in well until they run out of daylight then they will run remaining tubing tomorrow and test on Wednesday morning. |
1330549220 | 2012-02-29 | Salt Water Injection Well | No Violations | On site still running packer and tubing in well will test integrity tomorrow. |
1330644537 | 2012-03-01 | Salt Water Injection Well | No Violations | On site to witness setting of Baker Hornet Packer setting depth of packer was at 11,725 and 3.5 tubing attached to it, Universal Well Services flushed annulus of tubing with 600 bbl fresh water &inhibitor once flushed they reattached to packer and we pressure tested@2800psi with no decline in pressure and once this procedure was complete we pressure tested tubing@2800 psi also and once testing was completed they hooked well back up and proceeded to inject brine into injection zone. |
1330715428 | 2012-02-27 | Salt Water Injection Well | No Violations | On the day of my inspection I met Dave Ball on this site. They were trying to run a packer in. No violations noted. |
1334012841 | 2012-04-09 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today and according to well tender owner is planning on possibly plugging well back too a producing formation. |
1351932362 | 2013-05-16 | Salt Water Injection Well | No Violations | Inspection revealed that well is not in operation at this time in conversation with well owner stating that he is planning on plugging well back to a productive zone he also stated that he will be applying for permit in the near future. |
1361377269 | 2012-02-23 | Salt Water Injection Well | No Violations | Chipco service rig pulling 3 injection string from well they will run rebuilt packer back in well on 2/27/2012. |
1412548127 | 2014-10-03 | Salt Water Injection Well | No Violations | Meet with company rep Don Krieger and service rig crew to discuss upcoming plugging operation of said well and service company is planning on moving rig in on site 10/7/14. |
1413660145 | 2014-10-15 | Salt Water Injection Well | No Violations | Tagged wire line set bridge plug at 6070 and they set 500 cement plug from 6055-5555 and Universal Well Services pumped 168 sack plug and once plug was set they pulled tubing above plug and circulated hole volume to ensure that we could get our next procedure done tomorrow. |
1425164820 | 2010-12-09 | Drill / Deepen / Reopen | No Violations | On day of inspection well was being logged and sidewall cored by Baker Hughes. Well was TD at 13,727.This well is the deepest in the state. |
1472357703 | 2014-03-06 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down for repairs. |
1491570748 | 2013-02-20 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today.
Unloading pad was clean and neat. Exposed liner in tank area still needs to be covered with stone to help prevent rotting due to exposure to sunlight. |
1502985628 | 2010-10-07 | Drill / Deepen / Reopen | No Violations | On day of inspection Warren drilling rig #12 was running buttress thread pipe that was 20casing in a 26open hole. Depth is at 490and ran 465of 94lb/ft casing. Ran three baskets. Top basket 80down.Halliburton is cementing and we ran total of 1270 sks of cement.1230 and 40 sks to grout backside. Did not come around. Will cut 30and 20and grout down backside with 9sk grout mix. |
1509041464 | 2012-05-24 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation during my inspection .
Note It was noted that landowner has nearly completed restoration work at site and once vegetation has been established we will complete restoration due date. |
1534579919 | 2014-11-14 | Final Restoration | No Violations | Inspection revealed that restoration work at the site is satisfactory, dike area has been reclaimed and site restored and site has been seeded and mulched.
Note: Owner has waiver signed by landowner stating that unloading pad is to be left and the pump house and office building is to be left on site for landowner to use for his own purposes. |
1593636593 | 2012-03-05 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not running during my inpection, operator stated that he was waiting on pressure to drop before starting pump back up he also stated that they have hired contractor to complete restoration work at site they were on site during my inspection trying to reclaim south side of location . |
1609145635 | 2013-07-23 | Salt Water Injection Well | No Violations | Inspection revealed that well has been down awaiting on owner to apply for plug back permit and once plugged back they will produce gas from a upper producing formation. |
1659434952 | 2013-03-06 | Preliminary Restoration | No Violations | On the day of my inspection the site was satisfactory and preliminary restoration is now passed. No violations noted. |
1667542803 | 2014-06-17 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on owner to apply for plugging permit. |
1716527830 | 2012-04-25 | Salt Water Injection Well | No Violations | Well is down for possible plug back and convert to production well. |
1731939519 | 2013-11-27 | Salt Water Injection Well | No Violations | Inspection revealed that well is down awaiting on plug permit to be issued and once issued owner plans on plugging well. |
1855289927 | 2010-11-08 | Drill / Deepen / Reopen | No Violations | Checked in on rig still waiting on parts for bowl. |
1873370173 | 2013-09-24 | Salt Water Injection Well | No Violations | Well is still down awaiting on owner to apply for plug back permit. |
1885766581 | 2014-03-20 | Salt Water Injection Well | No Violations | No activity at site today owner is planning on plugging well as soon as permit is issued. |
1891693600 | 2012-02-22 | Salt Water Injection Well | No Violations | Released packer today and started to pull tubing and packer and once out of hole pack off wellhead and have packer rebuilt and run back into well the first of next week. |
1930920079 | 2012-02-21 | Salt Water Injection Well | No Violations | On site to determine if tubing has hole in or if packer has lost integrity it was determined that packer was the source of there leakage, we pressured up to 2400 psi on tubing with no decline in pressure. |
2007384690 | 2014-05-16 | Salt Water Injection Well | No Violations | Inspection revealed that well is still down waiting on owner to get plugging permit to plug said well. |
2023469275 | 2013-08-29 | Salt Water Injection Well | No Violations | Well is down awaiting on plug/plug back permit to be issued.
Note: Containment in good repair but unloading pad vault needs emptied. |
2038887306 | 2014-07-24 | Salt Water Injection Well | No Violations | Inspection revealed that owner is planning on plugging said well within the next month or so. |
2063558525 | 2012-09-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and well tender stated that he was pumping approximately 300 bbl daily into injection formation. |
2123526722 | 2013-01-14 | Salt Water Injection Well | No Violations | On the day of my inspection there was no brine truck activity at the well. No violations noted. |
217464141 | 2011-2-28 0:00: | CT | No Violations | 12.50 |
289658700 | 2013-6-27 0:00: | SW | No Violations | |
419637017 | 2011-3-3 0:00:0 | CT | No Violations | |
45575311 | 2011-6-14 0:00: | SW | No Violations | 2.00 |
510950934 | 2014-7-15 0:00: | SW | No Violations | |
517894390 | 2010-11-4 0:00: | DD | No Violations | 6.00 |
543401270 | 2014-2-19 0:00: | SW | No Violations | |
564788252 | 2013-8-14 0:00: | SW | No Violations | 2.00 |
604469729 | 2012-8-29 0:00: | SW | No Violations | |
65800577 | 2014-10-8 0:00: | SW | No Violations | 8.00 |
661352063 | 2011-3-28 0:00: | CT | No Violations | 1.00 |
73694681 | 2010-11-5 0:00: | DD | No Violations | |
774243355 | 2012-12-13 0:00 | SW | No Violations | |
805705950 | 2013-12-16 0:00 | SW | No Violations |