If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-20668 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.07,"lon":-81.02,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Union Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-000355 | |
Farm/Lease Name: BEDWAY N UNN BL | |
License Status: Drilling | |
License Date: 2014-06-26 | |
Spud Date: 2014-09-30 | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 40.070000 | |
Longitude: -81.020000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-08-29 | Proposed Formations:POINT PLEASANT, Issued Date:8/29/2012, Expired Date:8/29/2014 12:00:00 PM, Drilling unit acres:554.79, Proposed Well Type:OG, Proposed Well Class:EDPW |
Change of Owner | 2014-06-24 | Operator changed from 8063, XTO ENERGY INC. to 9193, AMERICAN ENERGY UTICA LLC |
APP | 2014-06-26 | Proposed Formations:TRENTON, Issued Date:6/26/2014, Expired Date:6/25/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Change of Owner | 2015-10-09 | Operator changed from 9193, AMERICAN ENERGY UTICA LLC to 9520, ASCENT RESOURCES UTICA LLC |
Construction Permit Expires | 2016-06-25 | |
Record Last Modified | 2018-11-19 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 02/05/2015 | 05/13/2015 | 8983 | 6,011,500.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | PTLAI161 | PTL | Corrosion Inhibitor | Alkyl Amine Surfactant | Proprietary | 5 | 0.00001915 | 11 |
Aromatic aldehyde | Proprietary | 10 | 0.00003830 | 22 | ||||
Ethoxylated alcohol | Proprietary | 10 | 0.00003830 | 22 | ||||
Fatty Alcohol Ethoxylate | Proprietary | 30 | 0.000114888 | 66 | ||||
Isopropyl Alcohol | 67-63-0 | 60 | 0.000229776 | 132 | ||||
PTL4070 | PTL | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 11.6182 | 6,674,360.0 | |
PTLMP075 | PTL | 7.5% HCL | Water | 7732-18-5 | 95 | 0.810642 | 465692 | |
Hydrochloric acid | 7647-01-0 | 15 | 0.127996 | 73530.3 | ||||
EC6111A | PTL | Biocide | Glutaraldehyde | 111-30-8 | 30 | 0.0104167 | 5984.12 | |
Water | PTL | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 87.3252 | 50,166,000.0 | |
Other Chemicals | Trade Secret Agent | Proprietary | 0 | 0.00203369 | 0 | |||
Trade Secret Agent | Proprietary | 0 | 0.031711 | 0 | ||||
Trade Secret Agent | Proprietary | 0 | 0.0347224 | 0 | ||||
PTLFR200 | PTL | Friction Reducer | Aliphatic hydrocarbon | Proprietary | 30 | 0.0197762 | 11360.9 | |
Oxyalkylated alcohol | Proprietary | 5 | 0.00329603 | 1893.48 |
For data sources see[3]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | ASCENT RESOURCES UTICA LLC | Brine | 19195 | 202 |
2016 | ASCENT RESOURCES UTICA LLC | Brine | 5906 | 239 |
2017 | ASCENT RESOURCES UTICA LLC | Brine | 6033 | 347 |
2018 | ASCENT RESOURCES UTICA LLC | Brine | 4375 | 363 |
2019 | ASCENT RESOURCES UTICA LLC | Brine | 865 | 87 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1314900545 | 2020-7-23 0:00: | PW | No Violations | 0.30 |
-1546361920 | 2014-8-19 0:00: | AM | No Violations | 0.50 |
-1788445169 | 2020-2-7 0:00:0 | PW | No Violations | 0.30 |
-2145819292 | 2018-11-15 0:00 | PW | No Violations | 0.50 |
-577523429 | 2014-8-18 0:00: | AM | No Violations | 0.50 |
-793887397 | 2017-7-20 0:00: | PW | No Violations | 0.50 |
-808252950 | 2018-4-6 0:00:0 | PW | No Violations | 0.50 |
0304540177 | 2017-12-13 | Production Wells | No Violations | This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing without any artificial lift technology present at this time. The well is piped to a gas processing unit and then to three 400 barrel production fluid holding tanks. Production records in RBDMS are current to 2017. |
0576871509 | 2014-09-30 | Casing String Witnessed | No Violations | On the day of my inspection the 24 mine string was being ran and cemented. See cement ticket for details. No violations noted. |
0577523429 | 2014-08-18 | Administrative Inspection | No Violations | Permission granted to set conductor at 90. Company drilled from 19:00 08/17/2014 till 07:00 08/18/2014 with a gain of only 20. It is certain that they have reach competent bedrock. |
0764446023 | 2018-08-22 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with a 4-string casing design with 5.5-inch diameter production casing that appeared to be open flowing. Annular pressure monitoring was in place, the 9.625-inch diameter intermediate casing gauge read 0 pounds per square inch, the 13.375-inch diameter surface casing gauge read 0 pounds per square inch. Production equipment included a Sand Trap, a line heater, and vertical fluid separator. There are three 400-barrel production fluid tanks shared with the other well on the pad. There were multiple Emergency Shut Down devices on location, Identification tags were present, and production was up to date. No violations were found at the time of my inspection. |
0793887397 | 2017-07-20 | Production Wells | No Violations | This well is equipped with 5.5-inch diameter production casing The well appears to be free flowing without any artificial lift technology present at this time. The well is piped to a production area and to sales. The area contains the gas processing units and three 400 barrel production fluid holding tanks. Production records in RBDMS are current to 2017. |
0808252950 | 2018-04-06 | Production Wells | No Violations | The well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing with no artificial lift technology present. The well is piped to a gas processing unit. From there, it is routed to a production area that contains three 400-barrel production fluid holding tanks. Annular pressures read on the gauges provided appeared to be 0 pounds on between the outside of the 9.625-inch diameter casing and the inside of the 13.375-inch diameter casing and 0 pounds between the outside of the 5.5-inch diameter casing and the inside of the 9.625-inch diameter casing. The production records within RBDMS are currently updated to 2017. |
1087813156 | 2014-09-29 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Nomac 81 was drilling the mine string. No violations noted. |
1407971586 | 2014-08-13 | Drill / Deepen / Reopen | No Violations | Onsite with Inspector Andrew Corder. Express Energy services is onsite with an auger rig. No drilling has occurred. See his report for additional details. |
1412611383 | 2014-10-03 | Drill / Deepen / Reopen | No Violations | Stopped by rig to retrieve cement ticket from surface job earlier in the week. Discussed notification procedures and expectations with company man. |
1538534494 | 2016-10-03 | Production Wells | No Violations | This well is currently equipped properly to be considered capable of production. The piping from the well leads to a gas processing unit and then to the tank battery. The tank battery consists of three 400 barrel production fluid tanks. The site appears to be in satisfactory condition. |
1542303993 | 2018-11-15 | Plug / Plug Back | No Violations | On the day of my inspection (3) wells were found present on location. The well said well appears to be producing under permit number of 3401320668-0100. I spoke to my supervisor Brent Bear and he will reach out to our permitting section for clairification on the previous activity addressing 3401320668-0000. |
1546361920 | 2014-08-19 | Administrative Inspection | No Violations | I received a call from Jerry Bright informing me that cementing of the 30 conductor would take place todat at 09:00. |
1821638871 | 2014-08-19 | Casing String Witnessed | No Violations | On the day of my inspection Express Energy had drilled the 36 open hole. The 30 conductor casing was ran and cemented. See cement ticket for details. No violations noted. |
1875444337 | 2015-09-24 | Preliminary Restoration | No Violations | On this day the well appeared to have all equipment to be considered capable of production. The erosion and sedimentation controls were of satisfactory condition and proper vegetation had been established. The preliminary restoration for this well has been completed. |
2145819292 | 2018-11-15 | Production Wells | No Violations | Status check inspection found the area affected by the well pad construction meets ORC 1509.072 with vegetation established. No erosion was noted on the containment berm or well pad slopes. The lease road and well pad surface was of stone construction and in good repair. The well pad does have an earthen berm around the perimeter with a 8 chain link fence surrounding the well pad. Signage is posted at the lease road entry point and the well pad entry point as well as at each well head. Hazard warning is posted on the tank battery which is situated on the well pad and consists of (3) steel construction 400 barrel fluid volume tanks that are situated inside a polymer lined steel containment dike area. The well head A&B sections are equipped with 2 diameter riser pipes with valves and gauges present for annular pressure monitoring. The A section which is the 13.375 diameter casing pressure measures zero pounds pressure. The B section which monitors the 9.625 diameter casing pressure measures zero pounds pressure also. There is 650 pounds pressure on the 5.5 diameter production casing. There is a production tree attached to the B section equipped with a emergency shut down device. |
304540177 | 2017-12-13 0:00 | PW | No Violations | 1.00 |
506662036 | 2020-7-23 0:00: | FR | No Violations | 0.30 |
576871509 | 2014-9-30 0:00: | CS | No Violations | 2.00 |
764446023 | 2018-8-22 0:00: | PW | No Violations | 0.50 |
For data sources see[6]