If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-20688 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.04,"lon":-81.12,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Kirkwood Township | |
Operator Name: GULFPORT APPALACHIA LLC | |
Well Pad ID: US-OH-000530 | |
Farm/Lease Name: SHUGERT | |
License Status: Producing | |
License Date: 2013-07-03 | |
Spud Date: 2012-06-10 | |
Spud Drilling Contractor: SIDEWINDER DRILLING INC | |
Final Drill Date: 2013-07-15 | |
Well Total Depth: 15058.00 ft | |
Configuration: Horizontal | |
Latitude: 40.040000 | |
Longitude: -81.120000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-03-12 | Proposed Formations:TRENTON, Issued Date:3/12/2013, Expired Date:3/12/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2013-07-03 | Proposed Formations:POINT PLEASANT, Issued Date:7/3/2013, Expired Date:7/3/2015 12:00:00 PM, Drilling unit acres:640, Proposed Well Type:OG, Proposed Well Class:EDPW |
Reached Total Depth | 2013-07-15 | |
Correction to Well | 2014-05-02 | CORRECTION TO TARGET & TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT. CORRECTED SURFACE ELEVATION. |
Completion Report Received | 2014-09-26 | |
Construction Permit Expires | 2015-07-03 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 10/19/2013 | 10/30/2013 | 8708 | 7,498,030.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | IC-250 | Stingray | Corossion Inhibitor | Water | 7732-18-5 | 80 | 0 | 0 |
Proprietary polycarboxylic acid mixture | Not Available | 20 | 0 | 0 | ||||
40/70 White | Minerva/Cadiz | Proppant | Sand | 14808-60-7 | 100 | 11.6383 | 0 | |
PROCLEAN 200 | U.S. Water | Corossion Inhibitor | Citric Acid, Food Grade | 77-92-9 | 52 | 0.00071 | 0 | |
Water | 7732-18-5 | 48 | 0.00065 | 0 | ||||
BioClear 5000 | Weatherford | Biocide | 2,2-dibromo-3-nitril oprop ionam ide | 10222-01-2 | 5 | 0.00121 | 0 | |
Water | 7732-18-5 | 95 | 0.02294 | 0 | ||||
Entecide QG40 | U.S. Water | Breaker | Water | 7732-18-5 | 56.4 | 0.00301 | 0 | |
n-ALKYL DIMETHYL BENZYL AMMONIUM CHLORIDE | 68424-85-1 | 5.5 | 0.00029 | 0 | ||||
DIDECYL DIMETHYL AMMONIUM CHLORIDE | 7173-51-5 | 8.3 | 0.00044 | 0 | ||||
GLUTARALDEHYDE | 111-30-8 | 27 | 0.00144 | 0 | ||||
ETHANOL | 64-17-5 | 2.8 | 0.00015 | 0 | ||||
Entegrate SC8060 WB | U.S. Water | Scale Inhibitor | 2-propenoic acid, sodium salt, polymer | 37350-42-8 | 10 | 0.00091 | 0 | |
Methyl Alcohol | 67-56-1 | 20 | 0.00183 | 0 | ||||
Aminotrimethylene Phosphonic Acid | 6419-19-8 | 10 | 0.00091 | 0 | ||||
Phosphoric Acid | 7664-38-2 | 1 | 0.00009000 | 0 | ||||
Water | 7732-18-5 | 59 | 0.00539 | 0 | ||||
Per Break | Stingray | Breaker | Ammonium Persulfate | 7727-54-0 | 99 | 0 | 0 | |
Entegrate NE 1100 | U.S. Water | Demulsifier | Water | 7732-18-5 | 60 | 0.02608 | 0 | |
Ethylene/Propylene Oxide Polymer | Not Available | 40 | 0.01738 | 0 | ||||
30/50 White | Minerva/Cadiz | Proppant | Sand | 14808-60-7 | 100 | 0 | 0 | |
Entegrate FR 7170 | U.S. Water | Friction Reducer | Water | 7732-18-5 | 48 | 0.04677 | 0 | |
C12-C14 Alcohol ethoxylated | 68439-50-9 | 3.1 | 0.00302 | 0 | ||||
Petroleum distillate hydrotreated light | 64742-47-8 | 28 | 0.02728 | 0 | ||||
Alcohols (C12-16), ethoxylated | 68551-12-2 | 3.1 | 0.00302 | 0 | ||||
Ammonium chloride | 12125-02-9 | 15 | 0.01462 | 0 | ||||
Alcohols (C10-16), ethoxylated | 68002-97-1 | 3.1 | 0.00302 | 0 | ||||
Clean Gel | Stingray | Guar Gel | heavy aliphatic | Not Available | 35 | 0.02595 | 0 | |
Solvent naphtha, (petroleum) | 64742-96-7 | 65 | 0.04819 | 0 | ||||
100 mesh | Minerva/Cadiz | Proppant | Sand | 14808-60-7 | 100 | 0.54723 | 0 | |
Fresh water | Stingray | Carrier | Water | 7732-18-5 | 100 | 87.2985 | 0 | |
Citric Acid 50% | Pace International | Acid | citric acid | 77-92-9 | 50 | 0.13033 | 0 | |
Water | 7732-18-5 | 50 | 0.13033 | 0 | ||||
X-linker | Stingray | Guar Gel | Water | 7732-18-5 | 70 | 0 | 0 | |
Ethylene Glycol | Not Available | 30 | 0 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-10-19 | H2O | 15 | 463386 Gal | 379500 | STINGRAY PRESSURE PUMPING LLC | STAGE 1/22
60 SHOTS STAGES 2-21 SEE IMAGES |
2013-10-30 | H2O | 15 | 297990 Gal | 494008 | STINGRAY PRESSURE PUMPING LLC | STAGE 22/22
60 SHOTS |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | GULFPORT ENERGY CORPORATION | 133586 | 869 | 18 |
2014 | GULFPORT ENERGY CORPORATION | 2666746 | 1921 | 329 |
2015 | GULFPORT ENERGY CORPORATION | 1453538 | 270 | 336 |
2016 | GULFPORT ENERGY CORPORATION | 990498 | 2 | 361 |
2017 | GULFPORT ENERGY CORPORATION | 636561 | 2 | 365 |
2018 | GULFPORT ENERGY CORPORATION | 536907 | 0 | 364 |
2019 | GULFPORT ENERGY CORPORATION | 114053 | 0 | 90 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | GULFPORT ENERGY CORPORATION | Brine | 2792 | 18 |
2014 | GULFPORT ENERGY CORPORATION | Brine | 12389 | 329 |
2015 | GULFPORT ENERGY CORPORATION | Brine | 0 | 336 |
2016 | GULFPORT ENERGY CORPORATION | Brine | 439 | 361 |
2017 | GULFPORT ENERGY CORPORATION | Brine | 1553 | 365 |
2018 | GULFPORT ENERGY CORPORATION | Brine | 1286 | 364 |
2019 | GULFPORT ENERGY CORPORATION | Brine | 240 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1502703703 | 2013-7-15 0:00: | DD | No Violations | 2.00 |
-1598593885 | 2013-7-16 0:00: | DD | No Violations | 1.00 |
-1603930217 | 2013-6-26 0:00: | DD | No Violations | 2.00 |
-1850374272 | 2013-6-19 0:00: | DD | No Violations | 3.00 |
-1865205082 | 2013-6-17 0:00: | DD | No Violations | |
-1902170184 | 2015-1-16 0:00: | PL | No Violations | 1.00 |
-819107851 | 2017-8-10 0:00: | PW | No Violations | 0.50 |
-931430533 | 2020-11-3 0:00: | PW | No Violations | 0.30 |
0018755468 | 2013-06-27 | Casing String Witnessed | No Violations | On the day of my inspection 10.75 casing was set and cemented. See casing ticket for information. |
0346411393 | 2013-06-24 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I checked Pason readings to ensure that the company had pressure tested the casing. Casing was pressured up to 360lbs after waiting 8 hours on cement to set and the pressure test was successful. No violations noted. |
0782295168 | 2018-05-15 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with 5.5 inch diameter production casing that was open flowing, all valves were open at the time of my inspection. Annular pressure monitoring was in place for the 9.625 inch diameter casing gauge read 0 pounds per square inch, the 13.375 inch diameter casing gauge read 0 pounds per square inch. Production equipment included a Separator, Gas Processing unit and line heater. There are 6- 400 barrel purge tanks shared with 3401320706, 3401320689, 3401320657. Identification tags were present, and production was up to date. |
0819107851 | 2017-08-10 | Production Wells | No Violations | This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing without any artificial lift technology present at this time. The well is piped to a gas processing unit and then to six 400 barrel production fluid holding tanks. Production records in RBDMS are current to 2017. |
0916437422 | 2013-06-25 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was reaming back to bottom. Company will run 10.75 casing soon. No violations noted. |
1046946472 | 2013-07-19 | Drill / Deepen / Reopen | No Violations | On the day of my inspection the 5.5 casing was set and cemented by Slumberger. No violations noted. |
1370919464 | 2013-06-10 | Drill / Deepen / Reopen | No Violations | Call from Nick with Gulfport who advised they were getting ready to spud this well. Will update GPS coords tomorrow. No violations noted. |
1371596062 | 2013-06-18 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was still rigging up and should be ready to spud tomorrow. No violations noted. |
1372698571 | 2013-07-01 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder was drilling @ 2590 and was planning to drill to 7800 and perform a formation integrity test. No violations noted. |
1373473032 | 2013-07-10 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was drilling ahead @ 9002. Water trucks were sucking excess water off of the pad. No violations noted. |
1374432874 | 2013-07-15 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was almost at total depth. No violations noted. |
1502703703 | 2013-07-15 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was drilling @ 14000 in the lateral section. No violations noted. |
1598593885 | 2013-07-16 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was at total depth and running casing. Total depth 15,058. No violations noted. |
1603930217 | 2013-06-26 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder #121was preparing to run 10.75 casing. Waiting on contact from a cement contractor that was available. |
1850374272 | 2013-06-19 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder 121 was rigging up. I spoke with the company man about containment plans for operations moving forward. No violations noted. |
1865205082 | 2013-06-17 | Drill / Deepen / Reopen | No Violations | On the day of my inspection Sidewinder #121 was rigging up. |
18755468 | 2013-6-27 0:00: | CS | No Violations | 7.00 |
1902170184 | 2015-01-16 | Preliminary Restoration | No Violations | The preliminary restoration for this well is completed. The pad is in satisfactory condition with proper erosion and sedimentation controls in place. Company shall continue to monitor the location to ensure the pad remains in satisfactory condition. Preliminary restoration passed. |
1918882024 | 2019-01-10 | Production Wells | No Violations | On site inspection found the well equipped with a lower A and upper B section with 2 diameter riser pipes attached to both sections, the riser pipes are equipped with valves and gauges for annular pressure monitoring with zero pounds pressure present on both gauges. The well is producing off the 5.5 diameter production casing with 3 primary master gate valves and one hydraulic valve present on the production tree. There is an emergency shut down control button at the well head along with at the production fluid storage area and at the well pad entry along with the gas processing units. The production facility consists of (6) steel construction tanks situated inside a polymer lined steel containment dike area. The well pad perimeter does not have a complete earthen berm surrounding it. The well pad surface and lease road is stone construction and in good repair. There is well identification on each of the (4) wells present on the pad along with at the well pad entry point. The tank battery has hazard warning labels. |
346411393 | 2013-6-24 0:00: | DD | No Violations | 2.00 |
625531725 | 2020-1-28 0:00: | PW | No Violations | 0.20 |
782295168 | 2018-5-15 0:00: | PW | No Violations | 0.50 |
916437422 | 2013-6-25 0:00: | DD | No Violations | 2.00 |
For data sources see[9]