Well Details

Well ID: 34-013-20726
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Warren Township
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-000841
Farm/Lease Name: AXLE WRN BL
License Status: Producing
License Date: 2013-11-12
Spud Date: 2014-03-14
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2014-09-29
Well Total Depth: 18245.00 ft
Configuration: Horizontal
Latitude: 39.980000
Longitude: -81.190000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-11-12 Proposed Formations:POINT PLEASANT, Issued Date:11/12/2013, Expired Date:11/12/2015 12:00:00 PM, Drilling unit acres:1000, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-11-29 CORRECTION TO SURFACE COORDINATES.
Correction to Well 2014-07-03 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Reached Total Depth 2014-09-29
Correction to Well 2015-01-23 UPDATE TO TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2015-06-24
Construction Permit Expires 2015-11-12
Change of Owner 2018-10-15 Operator changed from 8870, HESS OHIO DEVELOPMENTS LLC to 9520, ASCENT RESOURCES UTICA LLC
Record Last Modified 2018-10-25
Correction to Well 2018-10-26 CHANGE TO WELL NAME AND NUMBER. PREVIOUS-WARREN BEL A #3H-21.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2015-03-27 H2O 8 6858 Bbl 83920 US Well Services Inc STAGE 1/41

36 SHOTS STAGES 2-40 SEE IMAGES

2015-04-06 H2O 8 7355 Bbl 254940 US Well Services Inc STAGE 41/41

36 SHOTS

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2015 HESS OHIO DEVELOPMENTS LLC 1926453 12792 237
2016 HESS OHIO DEVELOPMENTS LLC 1435056 3664 360
2017 HESS OHIO DEVELOPMENTS LLC 785818 2643 359
2018 ASCENT RESOURCES UTICA LLC 508037 1020 327
2019 ASCENT RESOURCES UTICA LLC 143585 265 90

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2015 HESS OHIO DEVELOPMENTS LLC Brine 28134 237
2016 HESS OHIO DEVELOPMENTS LLC Brine 15611 360
2017 HESS OHIO DEVELOPMENTS LLC Brine 8151 359
2018 ASCENT RESOURCES UTICA LLC Brine 5571 327
2019 ASCENT RESOURCES UTICA LLC Brine 1916 90

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1383322955 2017-7-17 0:00: PW No Violations 0.50
-257120320 2020-2-20 0:00: PW No Violations 0.20
0292898662 2018-08-01 Production Wells No Violations Status check inspection found a total of 5 producing wells on the pad. All 5 wells along with all production equipment are situated inside a chain link fence enclosure. Proper well identification is posted at the well head and production facility and there is a gate along the lease road to limit access to the well pad. The well is of 5 string construction design with valves -riser pipes and gauges on the 13.375 and 9.625 well head sections. The 13.375 diameter casing pressure is zero pounds per square inch (psi) and the 9.625 diameter casing pressure is also zero psi, the 5.5 diameter casing pressure is 800 psi and the line pressure is 900 psi. The well is equipped with an artificial lift system. Inside a separate fenced in enclosure is the production equipment consisting of 5 line heaters and gas processing equipment with a continuous flair present on a flair stack while I was on location. The production fluid storage facility consists of 4 steel construction 400 barrel production tanks situated inside a polymer lined steel containment dike area. The well pad has no earthen perimeter berm and the mouse holes do not appear to of been properly plugged after the drilling process with cement. I left my contact information at the well site for the company to contact me concerning the mouse holes.
0640868765 2015-09-21 Preliminary Restoration No Violations On the day of my inspection the well appeared to have all the equipment to be considered capable of production. The tank battery contents included four 400 bbl oil storage tanks. The site has established proper vegetation and erosion controls. The preliminary restoration for this site has passed.
1052065441 2016-06-28 Production Wells No Violations This well is currently equipped with the proper equipment to be considered capable of production. During the inspection the well site appeared to be in satisfactory condition. No violations were noted.
1124287383 2019-7-11 0:00: PW No Violations 0.30
1288669758 2018-01-11 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing without any artificial lift technology present at this time. The well is piped to a production area that is surrounded by chain linked fence. The area contains the gas processing units and four 400-barrel production fluid holding tanks. The production records within RBDMS system are current to 2017.
1383322955 2017-07-17 Production Wells No Violations This well is equipped with 5.5-inch diameter production casing The well appears to be free flowing without any artificial lift technology present at this time. The well is piped to a production area that is fenced in. The area contains the gas processing units and four 400 barrel production fluid holding tanks. There was a flare that was burning on the day of my inspection. Production records in RBDMS are current to 2017.
1555569384 2017-05-21 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with 5.5 inch diameter production casing with a plunger lift system, valves were open at the time of my inspection. Annular pressure monitoring was in place for the 9.625 inch diameter casing gauge read 0 pounds per square inch, the 13.375 inch diameter casing gauge read 90 pounds per square inch. Production equipment included a separator, Gas Processing unit, line heater, gas scrubber and 4- 400 barrel purge tanks shared with 3401320719, 3401320725, 3401320727, 3401320728. Identification tags were present and production was up to date.
292898662 2018-8-1 0:00:0 PW No Violations 0.20
640868765 2015-9-21 0:00: PL No Violations 1.00

For data sources see[8]