X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-013-20862

Well Details

Well ID: 34-013-20862
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Richland Township
Operator Name: AMERICAN ENERGY UTICA LLC
Well Pad ID: US-OH-001086
Farm/Lease Name: PORTERFIELD B W RCH BL
License Status: Final Restoration
License Date: 2014-11-05
Spud Date: 2014-11-17
Spud Drilling Contractor:
Final Drill Date: 2014-11-19
Well Total Depth: 300.00 ft
Configuration: Vertical
Latitude: 40.090000
Longitude: -80.910000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2014-09-24 Proposed Formations:TRENTON, Issued Date:9/24/2014, Expired Date:9/23/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2014-11-05 Proposed Formations:POINT PLEASANT, Issued Date:11/5/2014, Expired Date:11/4/2016 12:00:00 PM, Drilling unit acres:359.82, Proposed Well Type:OG, Proposed Well Class:POOL
Plugged/Abandoned 2014-11-19 LOST HOLE WHILE DRILLING SURFACE. PLUG TO SKID AND DRILL 3H-
Reached Total Depth 2014-11-19 LOST HOLE WHILE DRILLING SURFACE. PLUG TO SKID AND DRILL 3H-
Change of Owner 2015-08-19 Operator changed from 9193, AMERICAN ENERGY UTICA LLC to 9520, ASCENT RESOURCES UTICA LLC
Change of Owner 2015-08-24 Operator changed from 9520, ASCENT RESOURCES UTICA LLC to 9193, AMERICAN ENERGY UTICA LLC - WELL TRANSFERRED TO ASCENT RESOURCES UTICA LLC IN ERROR LH WELL 8/24/2015 CM.
Construction Permit Expires 2015-11-05 LOST HOLE WHILE DRILLING SURFACE. PLUG TO SKID AND DRILL 3H-
Record Last Modified 2017-10-23 LOST HOLE WHILE DRILLING SURFACE. PLUG TO SKID AND DRILL 3H-

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1084509068 2019-9-9 0:00:0 PW No Violations 0.20
-1115572229 2014-12-18 0:00 DD No Violations 1.00
-1493098433 2014-11-22 0:00 PB No Violations 5.00
-1738002677 2018-7-31 0:00: PW No Violations 0.50
-399004416 2014-10-30 0:00 AM No Violations 0.50
-905599398 2018-5-9 0:00:0 PW No Violations 0.50
0354738028 2014-11-19 Plug / Plug Back No Violations The 17.5 hammer was lost in this hole. The company plans to plug this well back solid to surface soon. No violations noted.
0399004416 2014-10-30 Administrative Inspection No Violations I received a call that this well will be spudded.
0905599398 2018-05-09 Production Wells No Violations The well is equipped with 5.5-inch diameter production casing. The well appears to be free flowing with no artificial lift technology present. The well is piped to a gas processing unit. From there, it is routed to a production area that contains three 400-barrel production fluid holding tanks. Annular pressures read on the gauges provided appeared to be 100 pounds in between the outside of the 9.625-inch diameter casing and the inside of the 13.375-inch diameter casing and 1250 pounds between the outside of the 5.5-inch diameter casing and the inside of the 9.625-inch diameter casing. The production records within RBDMS are currently updated to 2017.
1115572229 2014-12-18 Drill / Deepen / Reopen No Violations (Report for the 3HA) Rig is waiting for an air package to begin drilling the 17.5 open hole section.
1418653660 2014-12-15 Administrative Inspection No Violations Patterson Rig 284 moving on pad to the 3H-A which is not in the system yet.
1493098433 2014-11-22 Plug / Plug Back No Violations On this day the well and rat hole was plugged. A 17.5 hammer bit was left in the hole. See cement report for details. No violations noted.
153872142 2020-7-23 0:00: FR No Violations 0.30
1738002677 2018-07-31 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with a 3 string casing design with 5.5 inch diameter production casing and 2.875 inch diameter tubing that appeared to be open flowing. Annular pressure monitoring was in place, the 9.625 inch diameter intermediate casing gauge read 1000 pounds per square inch, the 13.375 inch diameter surface casing gauge read 80 pounds per square inch. There were 3 defoamer tank vaults near the well heads. Production equipment included a Sand Trap, and gas processing unit, there was also a dehydration system with 2 phase separator and glycol injection on location. There are 3- 400 barrel production fluid tanks shared with 34013208610000, 34013208640000, 34013208630000, 34013208760000. There were multiple Emergency Shut Down devices on location, Identification tags were present, and production was up to date. No violations were found at the time of my inspection.
1996580760 2015-09-01 Preliminary Restoration No Violations On this day a service rig was present on location. There is chain linked fence present around pad area. The site was evaluated to confirm that proper vegetation and erosion controls had been established and maintained. This site has passed the preliminary restoration.
2021022610 2014-11-17 Drill / Deepen / Reopen No Violations On this day the Alpha Rig 9 had started to drill on this location. No violations noted.
354738028 2014-11-19 0:00 PB No Violations 0.50

For data sources see[3]

References