{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.11,"lon":-80.99,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Wheeling Township | |
Operator Name: ASCENT RESOURCES UTICA LLC | |
Well Pad ID: US-OH-001209 | |
Farm/Lease Name: BLAYNEY E WHL BL | |
License Status: Final Restoration | |
License Date: 2017-09-15 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 40.110000 | |
Longitude: -80.990000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2015-08-25 | Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:8/25/2015, Expired Date:8/24/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2017-09-15 | Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:9/15/2017, Expired Date:9/15/2019 12:00:00 PM, Drilling unit acres:160, Proposed Well Type:OG, Proposed Well Class:POOL |
Plugged/Abandoned | 2017-09-23 | LOST HOLE STATUSS PER INSPECTION |
Record Last Modified | 2019-01-31 | LOST HOLE STATUSS PER INSPECTION |
Construction Permit Expires | 2019-09-15 | LOST HOLE STATUSS PER INSPECTION |
For data sources see[2]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1265384727 | 2017-9-25 0:00: | PB | No Violations | 2.50 |
-817558574 | 2018-11-26 0:00 | PB | No Violations | |
0817558574 | 2018-11-26 | Plug / Plug Back | No Violations | Status check inspection found no well present in the plotted location and a previous inspection from 09/25/2017 indicating the well has been plugged. I notified my Supervisor Brent Bear and spoke with Ascent Representative Doug Bennett regarding the well plugging report. |
1265384727 | 2017-09-25 | Plug / Plug Back | No Violations | On the day of my inspection I witnessed Precision rathole had filled the 36 inch diameter hole drilled to 100 feet with 80 yards of cement on 9/23/17. I was notified and told them to proceed. The cement was stopped 30 inches below ground level and a steel plate with the API number was placed on top. Remaining hole will be filled with gravel to bring up to pad elevation. There is no casing and no cellar ring left in the hole. Ascent has applied for emergency permits for replacement of this hole as well as the 1H, 20967. |
1880354691 | 2020-7-23 0:00: | FR | No Violations | 0.40 |
1936175313 | 2017-09-21 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I was onsite to witness the cementing of the conductor casing. When I arrived on location I was informed by Ascent Rep Colden Parker that the auger bit had snapped off and they were currently fishing for the piece left in hole. This also happened on the 1H well, 20967. O-tex cementing is onsite. Water trucks were sent home and I will return when they retrieve the bit and are ready to cement. |
For data sources see[3]