34-013-21020

Well Details

Well ID: 34-013-21020
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Smith Township
Operator Name: XTO ENERGY INC.
Well Pad ID: US-OH-001370
Farm/Lease Name: BENNINGTON UNIT
License Status: Producing
License Date: 2016-07-01
Spud Date: 2016-07-08
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2016-08-20
Well Total Depth: 18186.00 ft
Configuration: Horizontal
Latitude: 39.980000
Longitude: -80.910000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2015-12-10 Proposed Formations:TRENTON, Issued Date:12/10/2015, Expired Date:12/9/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2016-07-01 Proposed Formations:POINT PLEASANT, Issued Date:7/1/2016, Expired Date:7/1/2018 12:00:00 PM, Drilling unit acres:226.113, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2016-08-20
Correction to Well 2016-10-07 CHANGE IN TARGET/TAKEPOINT AS DRILLED PLAT RCVD 09/7/16-ALE
Completion Report Received 2017-04-06
Record Last Modified 2017-10-23
Construction Permit Expires 2018-07-01

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2017-04-11 17874 17964 0
2017-04-11 10232 10369 0
17874 17964 0
10232 10369 0
10232 10369 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/27/2016 12/12/2016 9964 10,271,100.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KFR-16FW Keane Friction Reducer ammonium chloride 12125-02-9 1.5 0.00002783 26.955
Distillates (petroleum), hydrotreated light 64742-47-8 20 0.000371076 359.402
alcohols, C12-16, ethoxylated 68551-12-2 1 0.000764657 740.602
oleic acid diethanolamide 93-83-4 1.5 0.00114699 1110.9
Hydrochloric Acid (15%) Keane Acidizing Water 7732-18-5 85 1.19149 1,154,010.0
Hydrochloric Acid 7647-01-0 15 0.210263 203649
Water XTO Carrier/Base Fluid Water 7732-18-5 100 88.4959 85,712,000.0
KAI-13 Keane Acid Inhibitor Cinnamaldehyde 104-55-2 10 0.000185538 179.701
dipropylene gylcol, monomethyl ether 34590-94-8 20 0.000371076 359.402
formic acid 64-18-6 10 0.000185538 179.701
Ethoxylated alcohol Proprietary 10 0.000185538 179.701
propan-2-ol 67-63-0 5 0.00009277 89.851
Tar bases, quinoline derivs., benzyl chloride-quaternized 72480-70-7 10 0.000185538 179.701
ethanediol 107-21-1 40 0.000742152 718.805
MBC-516 Keane Biocide quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl, chlorides

68424-85-1 5.3 0.000886315 858.433
didecyldimethylammonium chloride 7173-51-5 8 0.00133031 1288.46
glutaral 111-30-8 26.7 0.00237686 2302.09
KSI-16 Keane Scale Inhibitor Ethylene glycol 107-21-1 5 0.000445105 431.103
Alkyl phosphonic acid Proprietary 5 0.00382329 3703.01
ammonia 7664-41-7 0.5 0.000382328 370.301
Sand (Proppant) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 9.9984 9,683,870.0
Other Chemical(s) Listed Above See Trade Name(s) List didecyldimethylammonium chloride 7173-51-5 8 0.00133031 1288.46
propan-2-ol 67-63-0 5 0.00009277 89.851
Ethylene glycol 107-21-1 5 0.000445105 431.103
formic acid 64-18-6 10 0.000185538 179.701
quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl, chlorides

68424-85-1 5.3 0.000886315 858.433
dipropylene gylcol, monomethyl ether 34590-94-8 20 0.000371076 359.402
Ethoxylated alcohol Proprietary 10 0.000185538 179.701
Tar bases, quinoline derivs., benzyl chloride-quaternized 72480-70-7 10 0.000185538 179.701
Cinnamaldehyde 104-55-2 10 0.000185538 179.701
oleic acid diethanolamide 93-83-4 1.5 0.00114699 1110.9
Water 7732-18-5 85 1.19149 1,154,010.0
alcohols, C12-16, ethoxylated 68551-12-2 1 0.000764657 740.602
Alkyl phosphonic acid Proprietary 5 0.00382329 3703.01
ammonium chloride 12125-02-9 1.5 0.00002783 26.955

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2016-12-12 H2O 15 217056 Gal 225920 Keane Frac STAGE 45 OF 45-SEE IMAGES FOR STAGES 2-44
2016-11-27 H2O 15 237804 Gal 217390 Keane Frac STAGE 1 OF 45

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2017 XTO ENERGY INC. 3492536 0 315
2018 XTO ENERGY INC. 2321809 0 332
2019 XTO ENERGY INC. 325873 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2017 XTO ENERGY INC. Brine 20893 315
2018 XTO ENERGY INC. Brine 23922 332
2019 XTO ENERGY INC. Brine 1924 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1387564967 2016-9-7 0:00:0 CT No Violations 1.00
-2115887115 2016-9-12 0:00: CT No Violations 1.00
1387564967 2016-09-07 Completion Testing No Violations On site with Austin Gutridge, a follow up for Emergency Response was conducted. The area that had been affected from the brine release appeared to be completely remediated. This well is currently awaiting completion operations.
1470835526 2016-08-07 Casing String Witnessed No Violations
1470853623 2016-08-10 Drill / Deepen / Reopen No Violations I was on site in response to a call regarding a release that occurred on this pad. Upon arrival I met with some XTO representatives. They explained that the release was due to a mechanical issue. The substance on site consisted of brine water and eco-friendly de-foamer. The area affected measured approximately 40ft*20ft. Following delineation, the company was remediating the area by vacuuming and diluting the affected portion of the pad. The valves on the out flow drains were closed. The company will continue to monitor the sump areas to ensure the clean-up is successful. The remediation efforts will continue until the conductivity and chloride readings reach an acceptable level. This release was within the pad area and did not extend past the berms. Nomac 79 is continuing drilling operations during the remediation.
2115887115 2016-09-12 Completion Testing No Violations An inspection was conducted on this site accompanied by Trish Cartmell. The well is currently awaiting completion efforts. Trish and I reviewed the remediation on site and determined that it was satisfactory.
958086980 2020-4-16 0:00: PL No Violations 0.30

For data sources see[10]

References