If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-21190 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.99,"lon":-81.04,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Goshen Township | |
Operator Name: RICE DRILLING D LLC | |
Well Pad ID: US-OH-001081 | |
Farm/Lease Name: RAZIN KANE | |
License Status: Producing | |
License Date: 2017-12-12 | |
Spud Date: 2017-11-02 | |
Spud Drilling Contractor: PATTERSON DRILLING | |
Final Drill Date: 2018-05-16 | |
Well Total Depth: 16777.00 ft | |
Configuration: Horizontal | |
Latitude: 39.990000 | |
Longitude: -81.040000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-02-28 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:2/28/2017, Expired Date:2/28/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2017-12-12 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:12/12/2017, Expired Date:12/12/2019 12:00:00 PM, Drilling unit acres:428.4635, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2018-05-11 | target location updated due to as drilled plat-TE |
Reached Total Depth | 2018-05-16 | |
Record Last Modified | 2018-08-23 | |
Correction to Well | 2018-08-24 | ACREAGE TAKE TARGET AS-DRILLED |
Construction Permit Expires | 2019-12-12 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
9505 | 9601 | 0 | |
16500 | 16672 | 0 | |
9505 | 9601 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1334785938 | 2020-7-10 0:00: | PL | No Violations | 0.40 |
-1528033029 | 2018-5-8 0:00:0 | CS | No Violations | 8.00 |
-563779108 | 2020-3-13 0:00: | PW | No Violations | 0.20 |
-731189539 | 2018-5-2 0:00:0 | DD | No Violations | 0.80 |
0731189539 | 2018-05-02 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I witnessed that Patterson UTI 296 was currently drilling the 12.5 inch diameter, deep intermediate section of the well bore. They were currently at 3000 feet drilling at approximately 145 feet an hour. Company man Greg Armstead informed me that Andrew Corder witnessed the 13.375 inch diameter casing, set at 2280 feet and they had good cement to surface. Greg Armstead said the estimated Total Depth for this well was 8527 feet and they would be cementing 9.625 inch casing on Monday, May 7. There were no violations at the time of my inspection. |
1510234044 | 2017-11-08 | Drill / Deepen / Reopen | No Violations | On the day of my inspection I arrived onsite to verify that the 30 inch diameter conductor was cemented to surface over the weekend. The cellar has not been set on this well. A large steel plate is covering the well and I am unable to verify that it was cemented to surface, but was told by George Durington with Rice that it was. Conductor was spudded on 11/2/17 and cemented 11/4/17 by Express. |
1528033029 | 2018-05-08 | Casing String Witnessed | No Violations | On the day of my inspection I witnessed that Patterson UTI 296 had drilled the 12.25 inch diameter hole to a depth of 8652 feet. Wyoming Casing Crew ran 8602 feet of 9.625 inch diameter J 55 casing at 40.0 pound per foot. BJ Services was on site and rigged up their cement head, loaded lines with 5 barrels of fresh water and pressure tested to 5000 pounds per square inch. BJ Services broke circulation, pumped 20 barrel of Multibond at 11 pounds per gallon with 2.23 cubic feet per sack yield, 20 barrels of Integrabond at 8.34 pound per gallon, 20 barrel of Multi Bond at 11 pound per gallon and 2.23 cubic feet per sack yield , and 607 barrels of 12 pound per gallon and 2.08 cubic feet per sack Onecem lead cement340132, and 93 barrels of 15.6 pounds per gallon with a yield of 1.22 cubic feet per sack Class A tail cement. Cement was displaced with 649 barrels of 13 pound per gallon oil base mud. Plug was bumped at 200 pounds per square inch and pressured up to 750 pounds per square inch and held for 5 minutes, floats held with 2 barrel of flow back. |
1541445229 | 2018-11-05 | Drill / Deepen / Reopen | No Violations | Status check inspection to update the well status. There are (6) wells on the pad-3 that are producing and 3 that have been drilled with production casing set. The three that were last drilled with production casing set are the # 1-# 3 & #5 wells. All 3 are in square type cellars and the well heads are not visible above ground level elevation. No annular pressure monitoring is visible above ground level. There is a natural gas compressor on the rear left hand corner (South West) side of the well pad. There is (2) gas processing units and 2 line heaters present on the well pad. The production facility consists of (5) 400 barrel tanks and one horizontal 100 barrel tank, all situated inside a polymer lined steel containment dike area. A 3rd party midstream facility is being installed at the left front corner (South) corner of the well pad, the perimeter berm has been removed. There also is 35 water trucks parked loaded and idling on the well pad, the well pad is being used for a staging area for water trucks. |
For data sources see[4]