X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-019-20429

Well Details

Well ID: 34-019-20429
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Rose Township
Operator Name: G & O RESOURCES LTD
Well Pad ID:
Farm/Lease Name: MORENO JOE
License Status: Producing
License Date: 1969-05-20
Spud Date: 1969-05-22
Spud Drilling Contractor:
Final Drill Date: 1969-07-09
Well Total Depth: 5355.00 ft
Configuration: Vertical
Latitude: 40.620000
Longitude: -81.260000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1969-05-20 311 STOCKER & SITLER INC GeoDate 5/20/69
Original Spud 1969-05-22
Completed 1969-07-09
Reached Total Depth 1969-07-09
Change of Owner 1999-07-20 Operator changed from 311, STOCKER & SITLER INC to 5785, M-J OIL COMPANY INC.
Change of Owner 2001-03-13 Operator changed from 5785, M-J OIL COMPANY INC. to 5894, G & O RESOURCES LTD
Record Last Modified 2013-12-31

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5224 5262 0
5224 5262 0
5224 5262 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2295 Bbl 135800

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 STOCKER & SITLER INC 371.00 358.00 365
1985 STOCKER & SITLER INC 1449.00 686.00 0
1986 STOCKER & SITLER INC 1331.00 114.00 365
1987 STOCKER & SITLER INC 780.00 475.00 365
1988 STOCKER & SITLER INC 0.00 307.00 0
1989 STOCKER & SITLER INC 0.00 337.00 365
1990 STOCKER & SITLER INC 0.00 407.00 365
1991 STOCKER & SITLER INC 0.00 101.00 365
1993 STOCKER & SITLER INC 628.00 218.00 365
1994 STOCKER & SITLER INC 1016.00 400.00 0
1995 STOCKER & SITLER INC 29.00 264.00 0
1996 STOCKER & SITLER INC 467.00 368.00 0
1997 STOCKER & SITLER INC 89.00 262.00 365
1998 STOCKER & SITLER INC 298.00 325.00 365
1999 M-J OIL COMPANY INC. 0.00 54.00 100
2000 M-J OIL COMPANY INC. 65.00 227.00 365
2001 M-J OIL COMPANY INC. 0.00 45.00 49
2002 G & O RESOURCES LTD 0.00 182.00 365
2003 G & O RESOURCES LTD 0.00 81.00 365
2004 G & O RESOURCES LTD 0.00 99.00 365
2005 G & O RESOURCES LTD 0.00 105.00 365
2006 G & O RESOURCES LTD 0.00 55.00 365
2007 G & O RESOURCES LTD 0.00 48.00 365
2008 G & O RESOURCES LTD 0.00 95.00 366
2009 G & O RESOURCES LTD 0.00 71.00 365
2010 G & O RESOURCES LTD 0.00 47.00 365
2011 G & O RESOURCES LTD 0.00 50.00 365
2012 G & O RESOURCES LTD 0.00 46.00 366
2013 G & O RESOURCES LTD 0.00 0.00 0
2014 G & O RESOURCES LTD 0.00 90.00 365
2015 G & O RESOURCES LTD 0.00 32.00 365
2016 G & O RESOURCES LTD 0.00 156.00 365
2017 G & O RESOURCES LTD 0.00 93.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 STOCKER & SITLER INC Brine 0 365
1985 STOCKER & SITLER INC Brine 0 0
1986 STOCKER & SITLER INC Brine 0 365
1987 STOCKER & SITLER INC Brine 0 365
1988 STOCKER & SITLER INC Brine 0 0
1989 STOCKER & SITLER INC Brine 0 365
1990 STOCKER & SITLER INC Brine 0 365
1991 STOCKER & SITLER INC Brine 0 365
1993 STOCKER & SITLER INC Brine 0 365
1994 STOCKER & SITLER INC Brine 0 0
1995 STOCKER & SITLER INC Brine 0 0
1996 STOCKER & SITLER INC Brine 0 0
1997 STOCKER & SITLER INC Brine 84 365
1998 STOCKER & SITLER INC Brine 165 365
1999 STOCKER & SITLER INC Brine 35 365
2000 M-J OIL COMPANY INC. Brine 52 365
2001 M-J OIL COMPANY INC. Brine 0 49
2002 G & O RESOURCES LTD Brine 163 365
2003 G & O RESOURCES LTD Brine 49 365
2004 G & O RESOURCES LTD Brine 22 365
2005 G & O RESOURCES LTD Brine 38 365
2006 G & O RESOURCES LTD Brine 0 365
2007 G & O RESOURCES LTD Brine 0 365
2008 G & O RESOURCES LTD Brine 0 366
2009 G & O RESOURCES LTD Brine 0 365
2010 G & O RESOURCES LTD Brine 0 365
2011 G & O RESOURCES LTD Brine 0 365
2012 G & O RESOURCES LTD Brine 0 366
2013 G & O RESOURCES LTD Brine 0 0
2014 G & O RESOURCES LTD Brine 0 365
2015 G & O RESOURCES LTD Brine 36 365
2016 G & O RESOURCES LTD Brine 97 365
2017 G & O RESOURCES LTD Brine 40 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1436465587 2012-5-31 0:00: PW No Violations
-1588006722 2015-3-31 0:00: PW No Violations
-1727000924 2018-10-22 0:00 PW No Violations 3.00
-1938023649 2018-10-18 0:00 PW No Violations
-2023057916 2015-6-23 0:00: PW No Violations
-838212500 2018-10-30 0:00 PW No Violations 0.30
-906368299 2018-10-31 0:00 PW No Violations 1.00
-949081910 2017-11-20 0:00 PW No Violations 0.50
0838212500 2018-10-30 Production Wells No Violations I was on site in response to complaint #5982, in which the complainant states the well leaks water during pumping operations. The pumping unit was not operating at the time of inspection, and I detected no visible leaking at the time of inspection.
0906368299 2018-10-31 Production Wells No Violations I was on site in response to complaint #5982, in which the complainant states the well leaks water during pumping operations which affects his domestic gas supply. The 8-5/8 casing was exposed and the unit was pumping at the time of inspection. I sat on site for one hour while the unit was pumping, and witnessed no leaks at the time.
0949081910 2017-11-20 Production Wells No Violations The well is equipped with a pumping unit and the production valves were in the open position. A compliance notice issued on 04/20/2015 was open pending proper identification at the wellhead. Correct identification was posted at the time of inspection. No violations were observed at the well or tank battery. The compliance notice can be closed.
1436465587 2012-05-31 Production Wells No Violations My inspection found the well has reported production for 2010 and no violaitons are noted at the well head or tank battery at this time.
1463409366 2016-05-16 Production Wells No Violations I conducted a compliance notice follow-up on the well. The well is equipped with an electrically-driven pumpjack and was producing at the time of inspection. No leaks were detected at the well. Current identification listing G&O as the owner with an updated emergency phone number is not posted at the well. The compliance notice will stay open until proper identification is posted at the well.
1479469142 2018-10-14 Production Wells No Violations I was on site in response to complaint #5982, in which the complainant states the well leaks water during pumping operations. The pumping unit was not operating at the time of inspection. I spoke with the operator, who will be meeting with me in the near future to excavate the area around the well head so that I can observe operations while the unit is pumping.
1540836297 2018-10-11 Production Wells No Violations
1543589638 2018-11-29 Production Wells No Violations I was on location in response to complaint #5982 in which the complainant states the well leaks which affects his domestic connection. The 4.5 casing was still exposed as per my request to the operator, and I detected no evidence of leaks at the time of inspection. I tested the standing water around the well head using a low range QuanTab which concluded in a reading of 326 ppm. I spoke to the complainant, Jon Ward, by phone on 11/30/2018 and informed him that this complaint will be closed as I have not detected any evidence of leaking from the well and have found no violations. I requested that he contact me in the future if he witnesses any issues/leaking at the well.
1588006722 2015-03-31 Production Wells Violations Noted I was on location to conduct a status check of this well with DOGRM Inspectors Heidi Scott and Ashley Raff. The well is equipped with a pump jack and is in production. The valves on the production line are cracked open. The well has a domestic line and valves are open. There was a 3 foot diameter stain of old oil around the 8 5/8 casing. The belt guard for the pump jack is laying on the ground. The tank battery has one 210 BBL production tank and one production tank cut in half, along with a mechanical separator. The 210 BBL production tank valve does have a bull plug on the tank valve. Another production tank that had been cut in half was open at the top and full of residual oil and water. Fallen trees and vegetation were on top of the oil/ water filled tank and the tank had been disconnected from the other production equipment and was outside of the tank battery. A gas odor was detected around the tank battery. The dike around the tank battery is eroding along the east side and is directly adjacent to a stream. The signage on the tank battery was very poor and needs replaced. Review of records in RBDMS indicates the last reported commercial production was in 2012 for this well. The lease road is stable and drivable. The following needs completed by:

1) Remove the oil/water filled open half tank and clean-up oil around the wellhead (4-28-15) 2) A new identification sign needs posted (4-28-15) 3) Repair dike (4-28-15) 4) Remove unused pipe and equipment (4-28-15) 5) Reinstall belt guard on the pump jack (4-28-15)

1727000924 2018-10-22 Production Wells No Violations I was on site in response to complaint #5982, in which the complainant states the well leaks water during pumping operations which affects his domestic gas supply. The operator had excavated around the well head to expose the 8.625 casing and 4.5 casing and turned the unit on to cycle. I witnessed operations for 2.5 hours during the pumping cycle. The domestic connection was equipped with a gauge, which displayed 80 psi after approximately one hour, and then held steady at 40 psi. I did not locate or witness any leaks before or during pumping operations. I located no violations at the well at this time, but will keep the complaint open pending further investigation.
1938023649 2018-10-18 Production Wells No Violations I was on site in response to complaint #5982, in which the complainant states the well leaks water during pumping operations. The pumping unit was not operating at the time of inspection. I spoke with the operator, who will be meeting with me in the near future to excavate the area around the well head so that I can observe operations while the unit is operating.
2023057916 2015-06-23 Production Wells No Violations A belt guard was installed on the pumpjack, and proper identification was posted. Unused pipe and equipment including the oil/water filled open half tank had been removed. The tank battery now consist of one, 210 barrel production tank which was shared with PN#2430. The tank battery has been moved south so that is now located further from the stream. A dike has been constructed around the tank battery. Proper identification has been posted at the tank battery.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1588006722 US-OH-115531 2015-04-28 General Safety
1588006722 US-OH-115532 2015-04-28 Failure to legibly identify well
1588006722 US-OH-115533 2015-04-28 No SPCC dike/or failure to keep dike free of water or oil
1588006722 US-OH-115534 2016-07-26 NONE18 Defective casing, leaking well

For data sources see[9]

References